© Edwards Limited 2012. All rights reserved.
Page 29
Edwards and the Edwards logo are trademarks of Edwards Limited.
OPERATION
A750-04-880 Issue F
4
OPERATION
Note:
The procedures in the following sections assume that your sealing liquid supply system is as shown in
, detail A, B or C.
4.1
General operation safety
Do not expose any part of your body to vacuum.
Do not operate the pump with the process inlet or outlet open to the atmosphere.
Do not operate the pump without sealing liquid in the pump.
During operation, prevent accidental contact with the hot pump. Note that if you use hot sealing liquid (up
to 70
o
C), the temperatures of the pump process outlet and seal surfaces will be higher than the temperature
of the sealing liquid supply.
Do not continue to operate the pump under cavitation conditions. If you do, the pump can be severely
damaged (see
).
Never disconnect any of the connecting pipelines (for example, the sealing liquid supply pipeline) when the
pump is operating.
Where necessary, wear ear defenders. The pump can be noisy during operation (refer to
).
4.2
Start-up
1. Refer to
, detail A, B or C. Open the sealing liquid supply valve (16) and the priming/drain valve (7).
Wait until liquid flows from the priming/drain valve (7). The pump is now primed. Close sealing liquid supply
valve (16) and then close the priming/drain valve (7).
2. Ensure that all isolation-valves (if fitted) in the process outlet pipeline are open.
3. Ensure that the flow regulating valve (12) is closed.
4. On ATEX Category 1 and 2 pumps configured for external seals flush supplies only: open the seals flush supply
valve (2).
5. Start the pump.
6. Open any isolation-valves (if fitted) in the process inlet pipelines.
WARNING
Obey the safety instructions and precautions listed below. If you do not, there may be a risk of
injury or death to people, or damage to the pump.
WARNING
Do not operate the pump without sealing liquid in the pump. If you do, there may be a risk of
explosion.
WARNING
Do not start the pump full of water as this could damage the pump.