© Edwards Limited 2014. All rights reserved.
Page 31
Edwards and the Edwards logo are trademarks of Edwards Limited.
Service, spares and accessories
A366-04-880 Issue A
7.4.6
Outlet mist-filter (clean applications)
The outlet mist-filter (see
, item 3) collects the oil contained in the oil-mist forming part of the discharge
gases. You can monitor the level of oil trapped in the filter, through a sight-glass. This mist-filter must only be used
for clean applications. You can return the trapped oil to your pump using the oil return kit. The mist-filter is supplied
with two ISO40 ‘C’ clamps, ISO40 elbow, two 40 mm co-seals, bolts, washers, mounting bracket and studs.
7.4.7
External oil filter
, item 2) is a free-standing filter. You can choose between two types of oil-filter.
The ‘A’ series uses an activated earth cartridge which provides chemical cleaning of the oil by removing acidic and
other aggressive contaminants. The ‘M’ series uses a pleated paper cartridge which does not provide chemical
filtering but removes abrasive particles down to 0.5 microns. You must check that the external oil filter you choose
is suitable for your application.
7.4.8
Solenoid-operated gas-ballast control valve
The solenoid-operated gas-ballast control valve (see
, item 5) gives you automatic or remote control of gas-
ballast. You can connect the valve to shut off gas-ballast when the pump is switched off and so prevent air from
returning to the system.
7.4.9
Thermostatic control valve
The thermostatic control valve (see
, item 6) promotes rapid pump warm-up and ensures optimum running
temperature by controlling cooling-water flow rate. This reduces water usage and running costs and significantly
improves vapour pumping performance.
Product
Item Number
MF300 Mist Filter
A462-04-000
Clean Application Oil Return Kit
A500-05-000
Product
Item Number
EOF300A External Oil Filter
A500-03-000
Activated Earth Element for EOF300A
A223-04-033
EOF300M External Oil Filter
A500-23-000
Mechanical Filter-element for EOF300M
A223-04-042
EOF300A and M Connection Kit
A364-01-020
Product
Item Number
EBV300D Solenoid-Operated Gas-Ballast
A500-17-930
Control Valve for E2M175 and E2M275
Product
Item Number
TCV300 Thermostatic Control Valve
A500-01-000