2 / 4
P/N 3102000-
EN • REV 002 • ISS 16MAR18
2.
Position the appropriate gasket over the backplate, ensuring that
the wire slot and other holes line up properly.
Remove the protective backing from the gasket surface and
carefully apply the gasket to the WG4, with the adhesive side
towards the appliance.
Press the gasket firmly against the back surface of the appliance
so that the gasket seats properly.
3. Place the opt
ional trim skirt over the electrical box, if desired. See
Figure 2
, items 4, 5, and 6. Also see “Specifications
” on page 3 for
a list of compatible boxes
.
4.
Feed the field wiring through the wire slots on the gasket and the
backplate. See
Figure 2, item 3 and Figure 3, item 1.
5.
Align the appliance and trim skirt (if applicable), and then secure
the backplate to the electrical box with the supplied screws.
Check the assembly to ensure that it is securely mounted.
6
.
Set the candela output.
The default candela setting is
D. To select a different candela
output, align the S2 indicator to the desired candela output. See
Figure 3
, item 6. For candela output ratings, see Table
8,
Table
9
,
and
Table
10.
7.
Set the strobe pattern.
The default strobe pattern setting is continuous. To use the
temporal strobe (private mode, which is not ULC listed), cut jumper
JP4
. See
Figure 3, item 4.
8.
Set the horn volume.
The default horn volume setting is high. To set the horn to low
volume, cut jumper JP3. See
Figure 3, item 2.
9
.
Set the horn pattern.
The default horn pattern is temporal. To use a continuous horn
pattern, cut jumper JP1. See
Figure 3, item 5.
10. Connect the signal circuit field wiring to the appropriate terminals,
noting that both the horn and the strobe are powered from the
same NAC.
You must observe polarity for the unit to function properly. See
11.
Remove the strobe protective cover shown in
Figure 3, item 3.
Note:
Do not
touch the glass of the strobe tube underneath, as this
may shorten the life of the glass tube.
12.
Position the cover over the backplate
, and then secure it with the
six cover screws.
13. Test the unit for proper operation.
Figure 1: Horn-strobe mounting positions
Figure 2: Exploded view of the assembly
(1)
Cover screws (6X)
(2)
Front cover
(3)
Backplate
(4)
Optional trim skirt
(5)
WG4 gasket
(6)
Electrical box
Figure 3: Jumper, switch, and protective cap locations
(1)
Wire slot
(2)
JP3 horn volume jumper
(3)
Protective cap
(4)
JP4 strobe pattern jumper
(5)
JP1 horn pattern jumper.
(6)
S2 candela
-setting switch