EdvoCycler™ Quick Guide

MAIN MENU ( Screen  A)

Move cursor UP and DOWN; select by pressing ENTER;  escape by pressing ESCAPE.

LOAD PROGRAM 
(Screen B)

Select one of 20 saved 
programs by using UP or 
DOWN and pressing ENTER.

Modify Saved Program

Select one of 20 saved 
programs by using UP or 
DOWN and pressing ENTER.

Create NEW Program

 

To modify the temperature, time, and number of cycles, scroll to value to be changed; 
press ENTER.  Using keys 0-9, punch in desired value.  NOTE:  You will need to keep 
same number of digits; so if 45 sec., you will need to enter 0045.
Can enter 001 - 999 for program numbers; 1 - 60 for # of cycles, 15 - 99 for tempera-
ture, and 0 - 1800 seconds for time. (Screen D)
Once finished, ESCAPE back to MAIN MENU.

TEMP HOLD PARAMS 
(Screen E)

Use to select whether or not 
you want the unit to keep the 
block at a constant tempera-
ture after an experiment is 
complete.  Press ENTER for 
YES or NO.

Select the hold temperature by pressing ENTER, then use the UP or DOWN keys to 
choose between 10 - 94,  Press ESCAPE when the desired temperature is selected.  
Scroll to RETURN and press ENTER to go back to MAIN MENU. 

NOTE:  The heated lid shuts off when the unit finishes a program and goes to hold.  
WARNING:  Running the unit for long periods of time at high or low temperatures will 
shorten the lifespan of the unit.

Change values by pressing ENTER and keying in numerical values.To modify the tempera-
ture, time and number of cycles, scroll to value to be changed; press ENTER.  Using keys 
0-9, punch in desired value.  NOTE:  need to keep same number of digits; so if 45 sec., 
enter 0045.  Once finished, ESCAPE back to MAIN MENU.

NOTE:  There are only 20 program slots; if you create a program in addition to 20, the 
last one will be deleted.

Delete Saved Program

 

Use DELETE SAVED PROGRAM to create a space for a new program when all program 
space is full.  Press ENTER to select one of 20 saved programs.  Press ENTER to choose 
and select YES or NO.
Once complete, you will automatically be placed back into the MAIN MENU.

PROGRAM SCREEN (Screen C)

Shows temperatures, times, and number of cycles; Press RUN to start.
Once running, press PAUSE to pause.  “P” will flash by the time.  
Press RUN again to continue.  
To abort the program while running, press ESCAPE.  Then choose YES or NO.  
Scroll UP or DOWN to choose.  NO will return to experiment.  YES will return to 
MAIN MENU.

IMPORTANT - Always check the PCR cycling parameter in the EDVOTEK manual that 
accompanies your experiment.  Compare the program to ensure that it matches the 
pre-programmed cycles.  If there has been a change, it will be necessary to modify the 
existing program to match the new parameters.

Содержание EdvoCycler

Страница 1: ...hase of the EdvoCycler Thermalcycler TABLE OF CONTENTS Introduction 2 Warnings 2 Operator Safety 2 Installation 2 After Use 2 User Maintenance 3 Guarantee 3 Contact Information 3 EdvoCycler Quick Guide 4 Getting Started 5 Load Saved Program 5 Modify Saved Program 6 Create New Program 6 Delete Saved Program 7 Temp Hold Params 7 Run Saved Program 8 Pause or Escape 8 ...

Страница 2: ... procedures If the equipment is used in a manner not specified by EDVOTEK the protection provided by the equip ment to the user may be impaired All EDVOTEK units have been designed to conform to interna tional safety requirements and are fitted with an over temperature cutout The cutout is preset to protect the unit If a safety problem should be encountered switch off at the mains socket and remov...

Страница 3: ... you may need to return the unit for repair The fuse is located in the back of the unit in the AC adapter Guarantee The unit is guaranteed against any defect in material or workmanship for two years Please fill out the warranty card as soon as possible to ensure proper warranty coverage The warranty period is from the date of purchase and within this period all defective parts will be replaced fre...

Страница 4: ...gram and goes to hold WARNING Running the unit for long periods of time at high or low temperatures will shorten the lifespan of the unit Change values by pressing ENTER and keying in numerical values To modify the tempera ture time and number of cycles scroll to value to be changed press ENTER Using keys 0 9 punch in desired value NOTE need to keep same number of digits so if 45 sec enter 0045 On...

Страница 5: ...DIFY SAVED PROGRAM CREATE NEW PROGRAM DELETE SAVED PROGRAM RUN PROGRAM LOAD SAVED PROGRAM Use this function if you are running an EDVOTEK kit The programs for most EDVOTEK PCR kits are pre loaded on the EdvoCycler and ready to run Simply follow ED VOTEK instructions for preparing DNA samples for PCR and place tubes in the EdvoCycler The block holds only 0 2 ml PCR tubes if PCR sample is prepared i...

Страница 6: ...nge and press enter When the item disappears enter the new parameter 4 Scroll to another setting you wish to modify After you are satisfied with the changes to the program press the escape button and the changes will be saved Time is entered as seconds i e 30 seconds is displayed as 0030 2 minutes is displayed as 0120 5 To run the modified program scroll to LOAD SAVED PROGRAM and follow the direct...

Страница 7: ... at the Cycles default Enter the number of cycles for the PCR cycling steps The number to the right is the total number of cycles and the number to the left will display as the current cycle in progress DELETE SAVED PROGRAM The EdvoCycler can hold 20 saved programs From time to time it may be necessary to delete old programs to make room for new programs Remember once a program is deleted it canno...

Страница 8: ...temporarily hold a cycle at a certain point USE EXTREME CAUTION WHEN OPENING THE LID AND REMOVING SAMPLES FROM THE BLOCK THE HEATED LID AND BLOCK WILL BE VERY HOT 2 When ready to return to the program replace samples to the block close the lid and push the RUN button 3 To stop the program while it is running press the escape button Press the up or down button to YES and press enter to abort the pr...

Отзывы: