Quick start procedure: 

 

PC or Mac Computer 

 

Materials needed: 

 

900-260 Anemometer Sensor 

 

900-213 USB Module 

 

A USB to mini USB cable (which comes with the 
900-213) 

 
Your  anemometer  sensor  needs  to  be  connected  to  a 
900-213 module.  The 900-213 module then connects 
to  a  computer  via  a  USB  to  mini-USB  cable.    Please 
note  that  you  cannot  plug  the  anemometer  sensor 
directly into the computer. 
 
Resident  PC  software  and  browser  based  application 
can be downloaded for free at 

WWW.EDULAB.COM

 

as well as a full software user guide.

  

Note:

  Make  sure  not  to  download  and  install  both 

types of software they will conflict on the computer. 

 

Procedure: 

 
1.

 

Install the Edu-Logger software 

2.

 

Connect the 900-213 module to the PC or Mac 

3.

 

Connect  the  anemometer  sensor  to  the  900-213 
module (they directly plug together).  Please note 
there is no calibration required for this sensor. 

4.

 

Open the Edu-Logger software. 

5.

 

Once  a  anemometer  sensor  logo  appears  on  the 
left  side  of  the  screen  the  probe  has  been 
automatically  identified  and  you  can  begin 
experimentation. 

6.

 

If  the  anemometer  sensor  is  not  automatically 
identified then click the “Search for sensors” icon 
to find the sensor. 

7.

 

Select the  “On-line experiment” button; this  will 
open a graph below. 

Содержание 900-260

Страница 1: ...Edu Logger Anemometer Logger Sensor Guide 900 260 ...

Страница 2: ...e sensor comes pre calibrated so you can start experimentation right out of the box using this guide Hundreds of possible experimental subjects that can be done with the 900 260 sensors are weather studies photosynthesis rates animal behavior insect flight and many more The anemometer sensor uses the following units of measure Kilometers per hour km hr An SI measurement of velocity Miles per hour ...

Страница 3: ...er guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu Logger software 2 Connect the 900 213 module to the PC or Mac 3 Connect the anemometer sensor to the 900 213 module they directly plug together Please note there is no calibration required for this sensor 4 Open the Edu Logger software 5 Once a anemometer sensor...

Страница 4: ...rials needed 900 260 Anemometer Sensor 900 268 WiFi module 900 215 Battery Your anemometer sensor needs to be connected to a 900 268 module The 900 268 module will create a closed Edu Logger WiFi network which will stream the Edu Logger data to a device of your choosing Once your device is wirelessly connected to the Edu Logger network you can run experiments and collect data through a browser of ...

Страница 5: ... Module ID found on the back of the 900 268 device Edu LoggerXXXX for example 8 Give your device about 20 seconds to connect to the 900 268 9 Once the device is connected go to your browser and type the website wifi201 com into the URL bar then wait for 30 60 seconds 10 You will see a Control mode icon in the browser click on this icon 11 The browser will then load a new screen and begin to auto d...

Страница 6: ...ll return the unit to WiFi mode Operation with Edu Logger viewer Materials needed 900 260 Anemometer Sensor 900 272 Viewing Module 900 215 Battery Procedure 1 Connect the anemometer sensor to the left side of the viewer 2 Connect the 900 215 module to the right side of the viewer 3 The 900 272 will auto detect the sensor and you will see it appear on the left side of the screen 4 Once the sensor a...

Страница 7: ...ings first connect to your chosen device PC Mac tablet smart device and select the Module setup button For more information on how to change the experiment settings view quick start procedure section for your chosen device in this document 4 After the experiment has concluded when the Start Stop button is pressed again or the data collection period ends connect the sensor to your chosen device ful...

Страница 8: ...ey directly plug together Please note there is no calibration required for this sensor 3 Open the Edu Logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the menu 6 If prompted to clear the graph click either the Off line experiment or On line experiment whichever you are using 7 Click Clear experiment results 8 Resume from step 4 ...

Страница 9: ...ation modes 0 to 75 mph 0 to 120 km hr ADC resolution 15 bit Resolution 0 01 mph 0 01 km hr Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Durable anemometer probe attached by a strong rubber coated wire Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated sensing eq...

Страница 10: ...r example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software Inside of the anemometer sensor a magnet is situated within a metal coil The magnet is connected directly to the wind speed detector which causes the magnet to spin with the same velocity as the wind propelling it The shaft is installed in a bearing and has a magnet ...

Страница 11: ...the anemometer sensor Store in a box at room temperature out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the product caused by improper use abuse or incorrect storage Sensors with a shelf life such as ion selective proves have a warranty of 1 year Sh...

Страница 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10202013 ...

Отзывы: