background image

11 

 

Change in time between two gates:

 

 
Change in time between two photo gates requires two 
Edu-logger photo gate sensors and an object or timing 
card with a known width. 
 
1.

 

Click the “Experiment Setup” button in the Edu-
logger  software  and  select  “Change  in  time 
between two gates”. 

2.

 

The  graphic  demonstrates  the  basic  idea  of  what 
your experimental setup should look like. 

3.

 

Measure  and  input  the  width  of  your  object  (in 
millimeters) into the text field labeled “X[mm]”. 

4.

 

Assign  each  of  your  photo  gate  sensors  to  both 
the “Sensor A” and “Sensor B” position. 

5.

 

Click  “Save”  and  then  you  are  ready  to  begin 
data collection. 

 

Velocities with timing card:

 

 
Velocities  with  timing  card  experiment  requires  one 
Edu-logger photo  gate sensor and an object or timing 
card  (a  multi  'flag'  is  recommended).  A  known  width 
is  not  required  for  the  time  measurements,  it  is 
however required for velocity calculations.   
 
1.

 

Click the “Experiment Setup” button in the Edu-
logger  software  and  select  “Velocities  with 
timing card”. 

2.

 

The  graphic  demonstrates  the  basic  idea  of  what 
your experimental setup should look like. 

3.

 

Choose  the  expected  experiment.  A  longer 
duration  will  include  less  samples.  Click  “Save” 
and  then  you  are  ready  to  begin  data  collection 
(scroll the menu down to see the save button). 

4.

 

You  will  get  the  time  difference  in  which  every 
black  flag  went  through  the  photo  gate. 
Velocities  can  be  calculated  by  dividing  the  flag 
width by the time difference.  

Содержание 900-209

Страница 1: ...Edu logger Photo Gate Logger Sensor Guide 900 209 Edu logger photo gate logger sensor 900 209...

Страница 2: ...servation of energy force momentum and many more The photo gate sensor uses an infrared beam which detects if an object is passing through it Therefore the sensor actively reads out as open or blocked...

Страница 3: ...oto gate sensor cannot work at off line mode because the computer is mandatory for its operation options The off line option is eliminated when the software finds that the photo gate sensor is connect...

Страница 4: ...r guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu logger software 2 Connect the 900 213 module to the PC or Mac 3...

Страница 5: ...9 Click on the experiment set up button to change the experiment settings if need be experiment duration for example 10 The photo gate sensor will give a live reading in the box to the left of the scr...

Страница 6: ...ed 2 Connect a 900 215 module to the right side of the 900 268 module 3 Although not required we recommend plugging the 900 215 to an outlet using a USB to mini USB charger such as a typical cell phon...

Страница 7: ...detect the sensor s select Search for sensors 13 Once the sensor is found you will see an icon on the left side of the screen for the photo gate sensor The icon will display real time data 14 Click on...

Страница 8: ...t Setup button after your photo gate sensor has been detected Timing cards Making timing cards is a unique option to further customize any experiment with the Edu logger photo gate sensor To make timi...

Страница 9: ...two gates The velocity with two gates option is ideal for experiments which examine collisions between two objects of known width and mass 1 Click the Experiment Setup button in the Edu logger softwar...

Страница 10: ...d then you are ready to begin data collection Acceleration with two gates Acceleration with two photo gates requires two Edu logger photo gate sensors and an object or timing card with a known width 1...

Страница 11: ...ities with timing card Velocities with timing card experiment requires one Edu logger photo gate sensor and an object or timing card a multi flag is recommended A known width is not required for the t...

Страница 12: ...ey directly plug together Please note there is no calibration required for this sensor 3 Open the Edu logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the enu 6...

Страница 13: ...00 s Resolution 100 s Max sample rate S sec 10 000 Sensor features Fully digital data Rugged plastic ergonomic case Internally housed infrared transmitter and detector Photo gate handle with three thr...

Страница 14: ...ital data in the correct scientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The Edu...

Страница 15: ...of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the p...

Страница 16: ...16 Thank you for using Edu logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013...

Отзывы: