The Edu-Logger relative humidity sensor can be used 
for any science experiment which requires an accurate 
relative  humidity  reading  such  as  in  the  fields  of 
Biology,  Physiology,  Exercise  Science,  Chemistry, 
Environmental  Science,  Earth  Science,  Weather 
Science, Botany, Entomology, etc.  
 
The  sensor  comes  pre-calibrated  so  you  can  start 
experimentation right out of the box using this guide.  
 
Hundreds  of  possible  experiments  that  can  be 
performed  with the  900-207 sensors are: perspiration, 
photosynthesis  rates,  insect  behavior,  water  vapor 
emitting chemical reactions, ecological studies, animal 
behavior and weather patterns. 
 
Relative  humidity  is  a  measurement  which  examines 
the  ratio  of  water  vapor  present  in  the  air  compared 
with the maximum amount of water vapor that the air 
can hold for a specific temperature. 

 

Data  is  presented  as  a  percentage  which  is  the 
ratio  of  the  amount  of  water  vapor  in  the  air 
versus  the  maximum  amount  that  could  be 
allowed at a given temperature.  

 

 

Содержание 900-207

Страница 1: ...Edu Logger Relative Humidity Logger Sensor Guide 900 207...

Страница 2: ...he box using this guide Hundreds of possible experiments that can be performed with the 900 207 sensors are perspiration photosynthesis rates insect behavior water vapor emitting chemical reactions ec...

Страница 3: ...dulab com as well as a full software user guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu Logger software 2 Conne...

Страница 4: ...riment 12 To end data collection early click Stop experiment Tablet smart phone device Materials needed 900 207 Relative Humidity Sensor 900 268 WiFi Module 900 215 Battery Module Your relative humidi...

Страница 5: ...p to one minute 7 Take your tablet or smart phone go to the WiFi settings and select the Edu Logger network which matches the 900 268 Module ID found on the back of the 900 268 device Edu LoggerXXXX f...

Страница 6: ...y to the computer using the 900 268 To engage operation in this fashion press 3 times on the panel key Repeating this operation will return the unit to WiFi mode Operation with Edu Logger viewer Mater...

Страница 7: ...tton on the relative humidity sensor a red light will turn on for the duration of the experiment 3 To change the experiment settings first connect to your chosen device PC Mac tablet smart device and...

Страница 8: ...evice 2 Connect the relative humidity sensor to a 900 213 module they directly plug together Please note no calibration is required for this sensor 3 Open the Edu Logger software 4 Click the Tools ico...

Страница 9: ...H ADC resolution 16 bit digital Accuracy 5 RH Resolution 0 1 Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in...

Страница 10: ...body This technology allows the sensor to collect and then store the digital data in the correct scientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in s...

Страница 11: ...out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship The warranty is for a period of 3 years from the date of purchase and does not cover damag...

Страница 12: ...12 Thank you for using Edu Logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013...