4
INSTALLATION
For new installation see page 13
For existing installations no pulley calculations are required
Important notice: The installation must be carried out by qualified personnel, voltages can reach
300VDC. Installation must be of professional quality.
The controller is isolated from the battery he have an isolator inside,follow the connection diagram.
1-
Fix the main casing to a solid surface.
2-
Before drilling holes in main casing, unscrew the four corner bottom plate screws so to
protect the controller unit.
3-
Make wires pass through the bottom of the casing in a way to prevent water break
through.
4-
Refer to the Installation Diagram (P7) and hook-up exactly as illustrated. Re-verify hook-
up.
5-
Do not close the generator`s connection box for there is a possibility that F1 and F2 or F1
and F4 need to be reversed. If you have to respect color wire.
6-
Turn the ignition key to power up the controller without activating the generator. Note:
the controller must stay activated during the start up procedure to insure a good start
up; that is why it is connected to ignition.
7-
The controller can display the actual isolation of electromagnetic system .
This message is for information unly push right arrow. Now you can select the next
Isolation value with up and down arrow. If the isolation go under the selected value
An alarm appear unly for inform you the evolution of system isolation . The system still
working.
8-
It is now time to program the system according to your system requirements; the default
settings are for an electromagnet of 230VDC. Refer to page 9.
9-
Start the engine!
10-
Adjust throttle to a maximum to maintain a good hydraulic pressure.
11-
Activate the command button or the upper arrow to engage magnetism.
12-
Observe the activity on the display, volts, amps, modulation field volts.
13-
This step should be made with a cold magnet to have a best amp in autoajustement .
Push on command switch or on up arrow to load and still the control switch on and wait
NEW SET UP message appears and release switch .
The controller will automatically adjust the magnetisation in respect to the volt parameter
He can change many parameter identified by (*).
The same parameter can be change manually after.
To improve efficiency fill out the Value Notification Table at the end of the manual (p20) and
call a technician (many parameters are to be taken into consideration).
For more information you may call us at 1-866-535-6686