FUNCTIONAL DESCRIPTION

OVERVIEW

CMP375 Series  is a very versatile, safe and high-tech charger for On-
Board electric vehicle (EV, PHEV) applications.

The   characteristics   of   a   CMP375   enable   the   safe   and   powerful 
charging of Lithium battery pack.

The   unit   contains   an   electrically   isolated   high   frequency   AC/DC 
converter with active Power Factor Correction circuitry that efficiently 
transforms   the   mains   AC   line   into   a   fully   controlled   DC   power   for 
charging the battery pack.

The   control   signals,   isolated   from   battery   pack   (SELV),   assure   for 
maximum   personal   protection   and   they  are   in   compliance   with   the 
applicable Standards.
Moreover, enable a simple connection with the charging infrastructure 
(BMS, VMU, Power Station).

An high protection degree (IP55 for the fan and IP67 for the cabinet) 
combined with a rugged design gives an exceptional usability in every 
situation and automotive environment.

An easy CAN setup permits connecting the units in parallel to realize 
stackable and redundant solution (up to 4 unit).

CMP375 series meets the safety and EMC requirements established 
by the CE mark and ECE regulation.

                  

EDN GROUP S.r.l.

  Via Mazzini, 10/12 – 20032 – CORMANO (MI) ITALY –  TEL. +39 02 66305120  FAX +39 02 61540938

CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL

e-mail:  

[email protected]

            web.site: 

www.edngroup.com

Содержание CMP375 Series

Страница 1: ...zini 10 12 20032 CORMANO MI ITALY TEL 39 02 66305120 FAX 39 02 61540938 CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL e mail sales edngroup com web site www edngroup com CM...

Страница 2: ...Data 7 Standard Applied 7 Mechanical Data 7 CONNECTORS SPECIFICATION 8 CONTROL PINS SPECIFICATION 9 GROUND KL31 9 CAN BUS 9 ENABLE 9 ALARM 9 LINE PRESENT 9 CHARGER CONNECTED D02 9 IGNITION RUN KL31 1...

Страница 3: ...y cause personal injury or material damage use additional safety and operational measures Such as limit switches guards etc Make sure that the battery pack and the mains power line characteristics are...

Страница 4: ...ssure for maximum personal protection and they are in compliance with the applicable Standards Moreover enable a simple connection with the charging infrastructure BMS VMU Power Station An high protec...

Страница 5: ...rger automatically turn on and off when SAE J1772 signal is present and valid A charger SLEEP mode Imax 15 mA drawn from KL30 is activated when the Proximity signal is lost for more that 1 minute The...

Страница 6: ...are not present CONNECTED CHARGING the charger provides HV DC output power FAN OUTPUT V03 The charger has an electrically floating output 24V 1A V03 used to supply the FAN assembly The FAN assembly is...

Страница 7: ...rotection over voltage etc Mains presence Relay contacts potential free Outputs Data Reduced Power Full Power Units V01 Output Voltage max 300 750 Vdc V01 Voltage Accuracy 1 V01 Output Current max 4 5...

Страница 8: ...w 24V 1A C IGNITION RUN KL15 8 16 volts D CHARGER CONNECTED Open Drain active low 24V 1A E DO2 Programmable Open Drain active low 24V 1A F FAN V03 24V 1A G FAN V03 24V 1A H BMS WAKE UP V02 12V 0 1A J...

Страница 9: ...nal puts the charger in Connected Charging state DC output On ALARM LINE PRESENT CHARGER CONNECTED D02 Four Open Drain Outputs connect to GROUND Imax 1 amp Alarm indicates when a charger s fault is de...

Страница 10: ...permits CAN communication when AC power is not present SAE J1772 fully compliance CONTROL PILOT SAE J1772 Control Pilot compliant signal PROXIMITY DETECTION SAE J1772 Proximity Detection compliant si...

Страница 11: ...of 12 User s Manual EDN GROUP S r l Via Mazzini 10 12 20032 CORMANO MI ITALY TEL 39 02 66305120 FAX 39 02 61540938 CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL e mail sale...

Страница 12: ...hat lethal voltages exist around this unit EDN GROUP cannot accept any liability concerning this danger EDN GROUP furthermore do not accept any liability for consequential damages which arose from the...

Отзывы: