CMP375 Series

CMP375 Series – Rev. 1.1, Issue 11/07                                                                                                                               Page 3 of 12

User's Manual   

 

SAFETY INFORMATION

Dear Customer, for your safety...

Read carefully the instructions in this manual.

WARNING - High DC voltages can be dangerous and lethal. 
Failure   to   install   or   operate   in   accordance   with   these 
instructions may result in damage to the charger or injury to 
the operator.

WARNING   -   The   charger   cannot   operate   without   a   safety 
ground  connection.  The  use   of  a   Ground   Fault   Interruption 
circuit is recommended.

WARNING - Do not attempt to open the charger. There is risk 
of electric shock even if the charger is unplugged. No user 
serviceable components inside.

Keep the charger from heating sources.

The   operating   charger   has   hot   surfaces.   Touching   the   hot 
charger can lead to injuries and burnings.

If safe operation cannot be longer ensured, STOP and secure 
it against operation.

If the charger failure or malfunction may cause personal injury 
or   material   damage,   use   additional   safety   and   operational 
measures. Such as limit switches, guards, etc.

Make  sure  that   the  battery  pack  and  the  mains power  line 
characteristics   are   in   the   correct   range   with   respect   to   the 
charger's technical data.

Charger should not be installed in a location which restricts 
airflow to the unit.

Failure to install and use the charger in accordance with this 
manual and data may impair the protection provided by the 
charger and void the manufacturer's warranty.

Have the charger installed and made operational by a skilled 
professional.

Never disconnect the battery plug out of unit without breaking 
the battery pack connection beforehand.

Remove the mains plug from the mains outlet before breaking 
the battery pack circuit.

Always   disconnect   mains   power   line   after   charging   and 
generally when the unit is not in use.

                  

EDN GROUP S.r.l.

  Via Mazzini, 10/12 – 20032 – CORMANO (MI) ITALY –  TEL. +39 02 66305120  FAX +39 02 61540938

CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL

e-mail:  

[email protected]

            web.site: 

www.edngroup.com

Содержание CMP375 Series

Страница 1: ...zini 10 12 20032 CORMANO MI ITALY TEL 39 02 66305120 FAX 39 02 61540938 CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL e mail sales edngroup com web site www edngroup com CM...

Страница 2: ...Data 7 Standard Applied 7 Mechanical Data 7 CONNECTORS SPECIFICATION 8 CONTROL PINS SPECIFICATION 9 GROUND KL31 9 CAN BUS 9 ENABLE 9 ALARM 9 LINE PRESENT 9 CHARGER CONNECTED D02 9 IGNITION RUN KL31 1...

Страница 3: ...y cause personal injury or material damage use additional safety and operational measures Such as limit switches guards etc Make sure that the battery pack and the mains power line characteristics are...

Страница 4: ...ssure for maximum personal protection and they are in compliance with the applicable Standards Moreover enable a simple connection with the charging infrastructure BMS VMU Power Station An high protec...

Страница 5: ...rger automatically turn on and off when SAE J1772 signal is present and valid A charger SLEEP mode Imax 15 mA drawn from KL30 is activated when the Proximity signal is lost for more that 1 minute The...

Страница 6: ...are not present CONNECTED CHARGING the charger provides HV DC output power FAN OUTPUT V03 The charger has an electrically floating output 24V 1A V03 used to supply the FAN assembly The FAN assembly is...

Страница 7: ...rotection over voltage etc Mains presence Relay contacts potential free Outputs Data Reduced Power Full Power Units V01 Output Voltage max 300 750 Vdc V01 Voltage Accuracy 1 V01 Output Current max 4 5...

Страница 8: ...w 24V 1A C IGNITION RUN KL15 8 16 volts D CHARGER CONNECTED Open Drain active low 24V 1A E DO2 Programmable Open Drain active low 24V 1A F FAN V03 24V 1A G FAN V03 24V 1A H BMS WAKE UP V02 12V 0 1A J...

Страница 9: ...nal puts the charger in Connected Charging state DC output On ALARM LINE PRESENT CHARGER CONNECTED D02 Four Open Drain Outputs connect to GROUND Imax 1 amp Alarm indicates when a charger s fault is de...

Страница 10: ...permits CAN communication when AC power is not present SAE J1772 fully compliance CONTROL PILOT SAE J1772 Control Pilot compliant signal PROXIMITY DETECTION SAE J1772 Proximity Detection compliant si...

Страница 11: ...of 12 User s Manual EDN GROUP S r l Via Mazzini 10 12 20032 CORMANO MI ITALY TEL 39 02 66305120 FAX 39 02 61540938 CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL e mail sale...

Страница 12: ...hat lethal voltages exist around this unit EDN GROUP cannot accept any liability concerning this danger EDN GROUP furthermore do not accept any liability for consequential damages which arose from the...

Отзывы: