INSTRUCCIONES IMPORTANTES DE SEGURIDAD

INSTRUÇÕES IMPORTANTES DE SEGURANÇA / IMPORTANT SAFETY INSTRUCTIONS

-7-

- 2 - 

Warning   

  To avoid possible electric shock or personal 

injury, and to avoid possible damage to the Meter or 

to the equipment under test, adhere to the following 

rules:

 

¾

 

Before using the Meter inspect the case.    Do 

not use the Meter if it is damaged or the case 

(or part of the case) is removed.    Look for 

cracks or missing plastic.    Pay attention to 

the insulation around the connectors.

 

¾

 

Inspect the test leads for damaged insulation 

or exposed metal.    Check the test leads for 

continuity.

 

¾

 

Do not apply more than the rated voltage, as 

marked on the Meter, between the terminals or 

between any terminal and grounding.

 

¾

 

The rotary switch should be placed in the right 

position and no any changeover of range shall 

be made during measurement is conducted to 

prevent damage of the Meter.

 

¾

 

When the Meter working at an effective voltage 

over 60V in DC or 30V rms in AC, special care 

should be taken for there is danger of electric 

shock.

 

¾

 

Use the proper terminals, function, and range 

for your measurements.

 

¾

 

Do not use or store the Meter in an 

environment of high temperature, humidity, 

explosive, inflammable and strong magnetic 

field.    The performance of the

 

Meter may 

deteriorate after dampened.

 

¾

 

When using the test leads, keep your fingers 

behind the finger guards.

 

¾

 

Disconnect circuit power and discharge all 

- 3 - 

high-voltage capacitors before testing 

resistance, continuity, diodes.

 

¾

 

Replace the battery as soon as the battery 

indicator 

 

appears.    With a low battery, 

the Meter might produce false readings that 

can lead to electric shock and personal injury.

 

¾

 

Remove the connection between the testing 

leads and the circuit being tested, and turn the 

Meter power off before opening the Meter 

case.

 

¾

 

When servicing the Meter, use only the same 

model number or identical electrical 

specifications replacement parts.

 

¾

 

The internal circuit of the Meter shall not be 

altered at will to avoid damage of the Meter 

and any accident.

 

¾

 

Soft cloth and mild detergent should be used 

to clean the surface of the

 

Meter when 

servicing. No abrasive and solvent should be 

used to prevent the surface of the Meter from 

corrosion, damage and accident.

 

¾

 

The Meter is suitable for indoor use.

 

¾

 

Turn the Meter power off when it is not in use 

and take out the battery when not using for a 

long time. Constantly check the battery as it 

may leak when it has been using for some time, 

replace the battery as soon as leaking appears. 

A leaking battery will damage the Meter.

 

 

- 4 - 

ķ

 

ĸ

 

Ĺ

 

Ŀ

 

ĺ

 

Ļ

 

Ľ

 

ľ

 

ļ

 

- 5 - 

ķ

 Transformer Jaws 

Pick up the AC Current flowing through the conductor 

ĸ

 Trigger 

Press the level to open the transformer jaws when the 

finger press on the level is released the jaws will close 

again. 

Ĺ

 Data Hold Switch 

A push switch (pushes on, push off, do not pull to select 

function). All function and ranges with this feature. 

ĺ

 Rotary Switch 

A rotary switch is used to select measurement Function 

and Range switch. 

Ļ

 Display 

3 ½ digits (1999 counts), decimal point, minus polarity, 

Over range and “

” indic

ators. 

ļ

 EXT Input Connect 

Used for accept insulation tester unit EXT banana plugs, 

when measurement insulation resistance. 

Ľ

 COM Input Connect 

Low input for all voltage, resistance, and continuity 

measurement will accept banana plugs. When 

measurement insulation resistance, used for accept 

insulation tester unit COM banana plugs. 

ľ

 

9Ÿ,QSXW&RQQHFW

 

High input for all voltage, resistance, and continuity 

measurement will accept banana plugs. When 

measurement insulation resistance, used for accept 

insulation 

WHVWHUXQLW9ŸEDQDQDSOXJV

 

Ŀ

 Drop-Proof Wrist Strap 

Prevents the instrument from slipping off the hand while 

in use. 

- 6 - 

General Specifications 

Max display: LCD 3 ½ digits, 1999 counts, 0.

5” high

 

Polarity: Automatic, indicated minus, assumed plus. 

Measure method: double integral A/D switch 

implement   

Sampling speed: 2 times per second 

Over-

load indication: “1” is displayed 

 

Operating Environment: 0

ć

~40

ć

, at <80%RH   

Storage Environment: -10

ć

~50

ć

, at <85%RH 

Power: 9V NEDA 1604 or 6F22 

Low battery indication: “

 

Static electricity: about 4mA 

Product Size: 230×68×37mm   

Product net weight: 240g (including battery) 

 

Technical Specifications 

Accuracies are guaranteed for 1 year, 23

ć

±5

ć

, less 

than 80%RH 

 

DC VOLTAGE 

RANGE RESOLUTION

ACCURACY

1000V

1V

±(1.0% of rdg + 5D)

 

OVERLOAD PROTECTION: 1000V DC or 750V rms 

for all ranges. 

 

AUDIBLE CONTINUITY 

RANGE

DESCRIPTION

Built-in buzzer sounds if resistance is

OHVVWKHQ“ȍ

 

OVERLOAD PROTECTION: 15 second maximum 

250V rms. 

OPERATOR’S

 

INSTRUCTION 

MANUAL

 

DIGITAL CLAMP METER

 

READ AND UNDERSTAND THIS MANUAL 

BEFORE USING THE INSTRUMENT.

 

WARNING 

- 7 - 

 

AC VOLTAGE 

RANGE RESOLUTION

ACCURACY

750V

1V

±(1.2% of rdg +5D)

 

RESPONSE: Average responding, calibrated in rms 

of a sine wave. 

FREQUENCY RANGE: 45Hz ~ 450Hz   

OVERLOAD PROTECTION: 1000V DC or 750V rms 

for all ranges. 

 

AC Current (Average sensing, calibrated to rms 

of sine wave) 

Ragnge Resolution

Accuracy (50Hz ~ 60Hz)

200A

100mA

±(2.5% + 13)

±(2.5% + 8)

for 800A and below

the reading is only for reference

for more than 800A

1000A

1A

 

Overload Protection: 1200A within 60 seconds. 

Jaw Opening: 2.09

” (5

3mm) 

 

Insulation Test (With option 500V insulation 

tester unit) 

Ragnge

Resolution

Accuracy

±(2% + 2)

±(4% + 2)

IRU0ȍDQGEHORZ

±(5% + 2)

for others

 

- 8 - 

 

RESISTANCE 

RANGE RESOLUTION

ACCURACY

ȍ

ȍ

±(1.0% of rdg +10D)

ȍ

±(1.0% of rdg +4D)

 

MAXIMUM OPEN CIRCUIT VOLTAGE: 3V. 

OVERLOAD PROTECTION: 15 seconds maximum 

250Vrms. 

 

OPERATING INSTRUCTIONS 

AC CURRENT MEASURE 

1. 

Make sure that “Data Hold” Switch

 is no pressed. 

2.  Set Range Switch to the ACA 1000A range. If the 

display indicates one or more leading zeros. Shift 

to the 200A range to improve the resolution of the 

measurement. 

3.  Press the trigger to open the transformer jaws 

and clamp one conductor only it is impossible to 

make measurements when two or three 

conductors are clamped at the same time. 

4.  Display reading is flow the conductor AC current. 

 

INSULATION RESISTANCE TESTER 

1.  Set Range Switch to the insulation tester 

0ŸUDQJH7KLVFRQGLWLRQWKHGLVSO

ay value 

is unstable that is normal. 

2. 

7KH LQVXODWLRQ WHVWHU XQLW 9Ÿ

-COM-EXT three 

banana plugs insert to clamp meter 

-COM-EXT three input connector. 

3.  Set the insulation tester unit range switch to the 

0ŸSRVLWLRQ

 

4.  Use the insulation tester unit of the test leads 

- 9 - 

connect its L-E input connect to being tested 

installation’s (test installation’s must be power off)

 

5.  Set the insulation tester power switch to the ON 

position. 

6.  Depress the PUSH 500V push-push switch, the 

500V on red LED lamp will light. Clamp meter 

display reading is the insulation resistance value 

LI WKH UHDGLQJ LV EHORZ 0Ÿ FKDQJH FODPS

PHWHU DQG LQVXODWLRQ WHVWHU XQLW WR 0Ÿ UDQJH

can be increase the accuracy. 

7.  If the insulation tester unit is not use the power 

switch must shift to power OFF position, and the 

test leads must leave the E-L input connect, that 

can be increase battery life and prevent electrical 

shock hazard. 

 

DC & AC VOLTAGE MEASUREMENT 

1. 

&RQQHFWUHGWHVWOHDGWR³9ȍ´MDFN%ODFNOHDGWR

³&20´MDFN

 

2.  Set RANGE switch to desired VOLTAGE position, 

if the voltage to be measured is not known 

beforehand, set switch to the highest range and 

reduce it until satisfactory reading is obtained. 

3.  Connect test leads to device or circuit being 

measured. 

4.  Turn on power of the device or circuit being 

measured voltage value will appear on Digital 

Display along with the voltage polarity. 

 

RESISTANCE MEASUREMENT 

1. 

5HGOHDGWR³9ȍ´%ODFNOHDGWR³&20´

 

- 10 - 

2.  RANGE switch to desired 

ȍ

 position. 

3.  If the resistance being measured is connec- ted to 

a circuit, turn off power and discharge all 

capacitors before measurement. 

4.  Connect test leads to circuit being measured. 

5.  Read resistance value on Digital Display. 

 

AUDIBLE CONTINUITY TEST 

1. 

Red lead to “V

ȍ

”, Black lead to “COM”.

 

2. 

RANGE switch to “ ” position.

 

3.  Connect test leads to two points of circuit to be 

tested. If the resistance is lower then 30

ȍ

±

ȍ

the buzzer will sound. 

 

BATTERY REPLACEMENT 

If “

” appears in display, it indicates that the 

battery should be replaced. 

 

ACCESSORIES 

¾

 

Operator’s instruction manual

 

¾

 

Set of test leads 

¾

 

Gift box 

¾

 

9-volt battery, NEDA 1604 6F22 type. 

PN: 31.11.2644 

ऩϾ⠜䴶

᥋Շ䨿(9[PPऩϾ⠜䴶

઀ষ

3.6 RESISTÊNCIA

 
3.6 CONDIÇÕES AMBIENTAIS
Temperatura normal de funcionamento: 18 ° C a 28 ° C (64 ° F a 82 ° F).
Condições de temperatura. 0 ° C a 50 ° C (32 ° F a 122 ° F)
Temperatura de armazenamento: -20 ° C a 60 ° C (-30 ° F a 140 ° F)
Humidade relativa: 80% max.

3.7 CARACTERÍSTICAS:
Método de medição: a integração inclinação dupla.
Velocidade da leitura: 3 leituras / segundo. Polaridade: automático com indicador negativo. Indicação de sobrecarga: 
apagando todos os dígitos, exceto para o ponto decimal e sinal.
Requisitos de alimentação: bateria de 9 V (6F22) indicador de bateria: no ecrã aparece um sinal quando a bateria só 
tem 20% de sua carga.
Display: LCD, 3 1/2 dígitos (leia max.1999). Retenção de Dados: (ESPERA DE DADOS) Aplica-se a todas as funções e 
características.
Dimensões: 123 x 7 x 9,4 cm (L x W x H) aprox. Peso: 310gr aproximadamente. (Incluindo a bateria).

3.9. ACESSÓRIOS

Manual do usuário pontas de prova bateria de 9 V (6F22) (únicamente de prova).

4. PARTES Y OPERACION 

4.1 MEDIÇÕES DE CORRENTE AC 

1. Verifique se o botão de bloqueio de dados "Data Hold" não está ativado.
2. Rode o selector em 200 A ou 1000 A Se não souber o valor sugerimos coloca-lo no maior valor.
3. Pressione o gatilho para abrir a pinça e ponha um único condutor na pinça. É impossível fazer medições quando 
dois ou três condutores são fixados ao mesmo tempo.
4. Verifique a leitura no ecrã.

- 2 - 

Warning   

  To avoid possible electric shock or personal 

injury, and to avoid possible damage to the Meter or 

to the equipment under test, adhere to the following 

rules:

 

¾

 

Before using the Meter inspect the case.    Do 

not use the Meter if it is damaged or the case 

(or part of the case) is removed.    Look for 

cracks or missing plastic.    Pay attention to 

the insulation around the connectors.

 

¾

 

Inspect the test leads for damaged insulation 

or exposed metal.    Check the test leads for 

continuity.

 

¾

 

Do not apply more than the rated voltage, as 

marked on the Meter, between the terminals or 

between any terminal and grounding.

 

¾

 

The rotary switch should be placed in the right 

position and no any changeover of range shall 

be made during measurement is conducted to 

prevent damage of the Meter.

 

¾

 

When the Meter working at an effective voltage 

over 60V in DC or 30V rms in AC, special care 

should be taken for there is danger of electric 

shock.

 

¾

 

Use the proper terminals, function, and range 

for your measurements.

 

¾

 

Do not use or store the Meter in an 

environment of high temperature, humidity, 

explosive, inflammable and strong magnetic 

field.    The performance of the

 

Meter may 

deteriorate after dampened.

 

¾

 

When using the test leads, keep your fingers 

behind the finger guards.

 

¾

 

Disconnect circuit power and discharge all 

- 3 - 

high-voltage capacitors before testing 

resistance, continuity, diodes.

 

¾

 

Replace the battery as soon as the battery 

indicator 

 

appears.    With a low battery, 

the Meter might produce false readings that 

can lead to electric shock and personal injury.

 

¾

 

Remove the connection between the testing 

leads and the circuit being tested, and turn the 

Meter power off before opening the Meter 

case.

 

¾

 

When servicing the Meter, use only the same 

model number or identical electrical 

specifications replacement parts.

 

¾

 

The internal circuit of the Meter shall not be 

altered at will to avoid damage of the Meter 

and any accident.

 

¾

 

Soft cloth and mild detergent should be used 

to clean the surface of the

 

Meter when 

servicing. No abrasive and solvent should be 

used to prevent the surface of the Meter from 

corrosion, damage and accident.

 

¾

 

The Meter is suitable for indoor use.

 

¾

 

Turn the Meter power off when it is not in use 

and take out the battery when not using for a 

long time. Constantly check the battery as it 

may leak when it has been using for some time, 

replace the battery as soon as leaking appears. 

A leaking battery will damage the Meter.

 

 

- 4 - 

ķ

 

ĸ

 

Ĺ

 

Ŀ

 

ĺ

 

Ļ

 

Ľ

 

ľ

 

ļ

 

- 5 - 

ķ

 Transformer Jaws 

Pick up the AC Current flowing through the conductor 

ĸ

 Trigger 

Press the level to open the transformer jaws when the 

finger press on the level is released the jaws will close 

again. 

Ĺ

 Data Hold Switch 

A push switch (pushes on, push off, do not pull to select 

function). All function and ranges with this feature. 

ĺ

 Rotary Switch 

A rotary switch is used to select measurement Function 

and Range switch. 

Ļ

 Display 

3 ½ digits (1999 counts), decimal point, minus polarity, 

Over range and “

” indic

ators. 

ļ

 EXT Input Connect 

Used for accept insulation tester unit EXT banana plugs, 

when measurement insulation resistance. 

Ľ

 COM Input Connect 

Low input for all voltage, resistance, and continuity 

measurement will accept banana plugs. When 

measurement insulation resistance, used for accept 

insulation tester unit COM banana plugs. 

ľ

 

9Ÿ,QSXW&RQQHFW

 

High input for all voltage, resistance, and continuity 

measurement will accept banana plugs. When 

measurement insulation resistance, used for accept 

insulation 

WHVWHUXQLW9ŸEDQDQDSOXJV

 

Ŀ

 Drop-Proof Wrist Strap 

Prevents the instrument from slipping off the hand while 

in use. 

- 6 - 

General Specifications 

Max display: LCD 3 ½ digits, 1999 counts, 0.

5” high

 

Polarity: Automatic, indicated minus, assumed plus. 

Measure method: double integral A/D switch 

implement   

Sampling speed: 2 times per second 

Over-

load indication: “1” is displayed 

 

Operating Environment: 0

ć

~40

ć

, at <80%RH   

Storage Environment: -10

ć

~50

ć

, at <85%RH 

Power: 9V NEDA 1604 or 6F22 

Low battery indication: “

 

Static electricity: about 4mA 

Product Size: 230×68×37mm   

Product net weight: 240g (including battery) 

 

Technical Specifications 

Accuracies are guaranteed for 1 year, 23

ć

±5

ć

, less 

than 80%RH 

 

DC VOLTAGE 

RANGE RESOLUTION

ACCURACY

1000V

1V

±(1.0% of rdg + 5D)  

OVERLOAD PROTECTION: 1000V DC or 750V rms 

for all ranges. 

 

AUDIBLE CONTINUITY 

RANGE

DESCRIPTION

Built-in buzzer sounds if resistance is

OHVVWKHQ“ȍ

 

OVERLOAD PROTECTION: 15 second maximum 

250V rms. 

OPERATOR’S

 

INSTRUCTION 

MANUAL

 

DIGITAL CLAMP METER

 

READ AND UNDERSTAND THIS MANUAL 

BEFORE USING THE INSTRUMENT.

 

WARNING 

- 7 - 

 

AC VOLTAGE 

RANGE RESOLUTION

ACCURACY

750V

1V

±(1.2% of rdg +5D)  

RESPONSE: Average responding, calibrated in rms 

of a sine wave. 

FREQUENCY RANGE: 45Hz ~ 450Hz   

OVERLOAD PROTECTION: 1000V DC or 750V rms 

for all ranges. 

 

AC Current (Average sensing, calibrated to rms 

of sine wave) 

Ragnge Resolution

Accuracy (50Hz ~ 60Hz)

200A

100mA

±(2.5% + 13)

±(2.5% + 8)

for 800A and below

the reading is only for reference

for more than 800A

1000A

1A

 

Overload Protection: 1200A within 60 seconds. 

Jaw Opening: 2.09

” (5

3mm) 

 

Insulation Test (With option 500V insulation 

tester unit) 

Ragnge

Resolution

Accuracy

±(2% + 2)

±(4% + 2)

IRU0ȍDQGEHORZ

±(5% + 2)

for others

 

- 8 - 

 

RESISTANCE 

RANGE RESOLUTION

ACCURACY

ȍ

ȍ

±(1.0% of rdg +10D)

ȍ

±(1.0% of rdg +4D)

 

MAXIMUM OPEN CIRCUIT VOLTAGE: 3V. 

OVERLOAD PROTECTION: 15 seconds maximum 

250Vrms. 

 

OPERATING INSTRUCTIONS 

AC CURRENT MEASURE 

1. 

Make sure that “Data Hold” Switch

 is no pressed. 

2.  Set Range Switch to the ACA 1000A range. If the 

display indicates one or more leading zeros. Shift 

to the 200A range to improve the resolution of the 

measurement. 

3.  Press the trigger to open the transformer jaws 

and clamp one conductor only it is impossible to 

make measurements when two or three 

conductors are clamped at the same time. 

4.  Display reading is flow the conductor AC current. 

 

INSULATION RESISTANCE TESTER 

1.  Set Range Switch to the insulation tester 

0ŸUDQJH7KLVFRQGLWLRQWKHGLVSO

ay value 

is unstable that is normal. 

2. 

7KH LQVXODWLRQ WHVWHU XQLW 9Ÿ

-COM-EXT three 

banana plugs insert to clamp meter 

-COM-EXT three input connector. 

3.  Set the insulation tester unit range switch to the 

0ŸSRVLWLRQ

 

4.  Use the insulation tester unit of the test leads 

- 9 - 

connect its L-E input connect to being tested 

installation’s (test installation’s must be power off)

 

5.  Set the insulation tester power switch to the ON 

position. 

6.  Depress the PUSH 500V push-push switch, the 

500V on red LED lamp will light. Clamp meter 

display reading is the insulation resistance value 

LI WKH UHDGLQJ LV EHORZ 0Ÿ FKDQJH FODPS

PHWHU DQG LQVXODWLRQ WHVWHU XQLW WR 0Ÿ UDQJH

can be increase the accuracy. 

7.  If the insulation tester unit is not use the power 

switch must shift to power OFF position, and the 

test leads must leave the E-L input connect, that 

can be increase battery life and prevent electrical 

shock hazard. 

 

DC & AC VOLTAGE MEASUREMENT 

1. 

&RQQHFWUHGWHVWOHDGWR³9ȍ´MDFN%ODFNOHDGWR

³&20´MDFN

 

2.  Set RANGE switch to desired VOLTAGE position, 

if the voltage to be measured is not known 

beforehand, set switch to the highest range and 

reduce it until satisfactory reading is obtained. 

3.  Connect test leads to device or circuit being 

measured. 

4.  Turn on power of the device or circuit being 

measured voltage value will appear on Digital 

Display along with the voltage polarity. 

 

RESISTANCE MEASUREMENT 

1. 

5HGOHDGWR³9ȍ´%ODFNOHDGWR³&20´

 

- 10 - 

2.  RANGE switch to desired 

ȍ

 position. 

3.  If the resistance being measured is connec- ted to 

a circuit, turn off power and discharge all 

capacitors before measurement. 

4.  Connect test leads to circuit being measured. 

5.  Read resistance value on Digital Display. 

 

AUDIBLE CONTINUITY TEST 

1. 

Red lead to “V

ȍ

”, Black lead to “COM”.

 

2. 

RANGE switch to “ ” position.

 

3.  Connect test leads to two points of circuit to be 

tested. If the resistance is lower then 30

ȍ

±

ȍ

the buzzer will sound. 

 

BATTERY REPLACEMENT 

If “

” appears in display, it indicates that the 

battery should be replaced. 

 

ACCESSORIES 

¾

 

Operator’s instruction manual

 

¾

 

Set of test leads 

¾

 

Gift box 

¾

 

9-volt battery, NEDA 1604 6F22 type. 

PN: 31.11.2644 

ऩϾ⠜䴶

᥋Շ䨿(9[PPऩϾ⠜䴶

઀ষ

1. Abraçadeira de plástico do transformador: Selecione a classe de corrente 
alternada que circula através do condutor, não sabendo é recomendado usar 
a escala mais alta.
2. Pinça: Pressione a alavanca para abrir a pinça. Quando a alavanca é 
liberada, a pinça fecha-se novamente.
3. Conservação de dados (Data Hold): Pressionando o botão pode bloquear 
a medição. Se o botão for liberado o multímetro continuará mostrando 
variações nas leituras. Este método pode ser aplicado em todas as funções 
ou medições.
4. Selector: Rodando o selector determina-se a função e a escala deseja 
medir.
5. Visor (Display/Ecrã): Display de 3 1/2 dígitos (1999), capaz de exibir 
automaticamente o ponto decimal, a polaridade negativa, sobrecarga e 
indicadores de "BAT LOW".
6. Isolamento Conector de entrada: Conector tipo banana para obter a 
medição da resistência.
7. COM conector de entrada: Conector tipo BANANA usado para medir 
tensão, resistência e provas de continuidade através da inserção da ponta de 
prova preto (negativo).
8. V / 

Ω

: Conector tipo BANANA usado para medir tensão, resistência e 

provas de continuidade através da inserção da ponta de prova vermelho 
(positivo).

Содержание 03209

Страница 1: ...orrecta instalaci n de sus art culos IMPORTADO POR www edmgrupo com ELEKTRO 3 S COOP C L F 43389675 Pol Ind Alba C de Barenys n 21 43480 Vila Seca Tarragona Spain www elektro3 com EUROPEA DE MATERIALE...

Страница 2: ...o y su cable fuera del alcance de los ni os menores de 8 a os Aseg rese de que los ni os no juegan con el aparato 3 No sumerja el cable ni el aparato en agua ni en ning n otro l quido 4 No deje nunca...

Страница 3: ...IMPORTANT SAFETY INSTRUCTIONS 3 2 Warning To avoid possible electric shock or personal injury and to avoid possible damage to the Meter or to the equipment under test adhere to the following rules Bef...

Страница 4: ...banana plugs When measurement insulation resistance used for accept insulation WHVWHU XQLW 9 EDQDQD SOXJV Drop Proof Wrist Strap Prevents the instrument from slipping off the hand while in use General...

Страница 5: ...verem sob a supervis o de um adulto Mantenha o aparelho e o cabo fora do alcance das crian as menores de 8 anos 3 N o submerja o cabo o aparelho em gua nem em qualquer outro l quido 4 Nunca deixe a ap...

Страница 6: ...the Meter or to the equipment under test adhere to the following rules Before using the Meter inspect the case Do not use the Meter if it is damaged or the case or part of the case is removed Look fo...

Страница 7: ...asurement will accept banana plugs When measurement insulation resistance used for accept insulation tester unit COM banana plugs 9 QSXW RQQHFW High input for all voltage resistance and continuity mea...

Страница 8: ...not be f the Meter ould be used when nt should be e Meter from use is not in use ot using for a battery as it for some time aking appears e Meter Transformer Jaws Pick up the AC Current flowing throu...

Страница 9: ...pect the test leads for damaged insulation or exposed metal Check the test leads for continuity Do not apply more than the rated voltage as marked on the Meter between the terminals or between any ter...

Страница 10: ...Range switch Display 3 digits 1999 counts decimal point minus polarity Over range and indicators EXT Input Connect Used for accept insulation tester unit EXT banana plugs when measurement insulation r...

Страница 11: ...ct red test lead to V jack Black lead to COM jack 2 Set RANGE switch to desired VOLTAGE position if the voltage to be measured is not known beforehand set switch to the highest range and reduce it unt...

Страница 12: ...dquiriu o produto GARANTIA O per odo de garantia de 24 meses a contar da data de compra e cobre todos os defeitos de fabrico no que se refere ao material e qualidade Esta garantia aplica se apenas se...

Отзывы: