Digital Thermometer and Vane Anemometer

Func. key - Back light control

1. Press and hold the FUNC. key for 1 sec. The back light will be turned on.

2. Press and hold the FUNC. key once again for a 1 sec. The back light will be

turned off. 

NOTE: If the back light is not closed within 60 seconds, it will turn ‘off’ automatically. 

4.5. Auto power off setting 

When the meter is powered on, it is under auto power off mode. This means the

meter will power itself ‘off‘ after 20 minutes if no keys are operation.

To override the auto power off mode follow the following instruction:

1. Press and hold the ON/OFF key until the LCD display ‘AP ON’. 

2. Press the UNIT key to select ‘AP ON’ or ‘AP OFF’.

3. Then press the FUNC. key to confirm the setting. 

AP ON  = Auto power off activated.

AP OFF  = Auto power off deactivated.

4. To revert back to the default setting switch the meter off and on again.

5. Maintenance

5.1. CLEANING INSTRUCTIONS

The meter may be wiped down with a wet sponge or cloth using a mild water

based detergent or anti-bacterial soap and rinsed under a gentle stream of cold

water.

NOTE: This unit is not designed for complete submersion or washing in water.

5.2. BATTERY REPLACEMENT

Use the following procedure:

When the battery voltage drops below the required operation range the 

symbol will appear on the LCD display and the batteries need to be replaced. 

1.  On the back of the meter, slide the battery cover in the direction of the 

arrowhead to open the battery cover.

2.  Replace the batteries with 3 new 1.5V batteries (AAA).

3.  Replace the battery cover.

6. PACK CONTENTS

• Digital multimeter

• Wrist strap

• Instruction manual

• DC1.5V x3 AAA batteries (installed)

• Carry Case

EDI-312-4020K_Instructions_Layout  30/04/2015  15:06  Page 7

Содержание TVA150

Страница 1: ...e C and F Range 0 4 20m s 80 4000fpm 10 50 C 14 122 F Resolution 0 1m s 1fpm 0 1 C 0 1 F Functions include Data hold LCD display with optional back light and Auto power off Complete with meter head co...

Страница 2: ...2 Content 1 GENERAL INSTRUCTIONS 3 2 TECHNICAL SPECIFICATIONS 4 3 DESCRIPTION 4 4 OPERATION INSTRUCTIONS 6 5 MAINTENANCE 7 6 PACK CONTENT 7 EDI 312 4020K_Instructions_Layout 30 04 2015 15 06 Page 2...

Страница 3: ...rvice from this meter please read this manual carefully 1 2 During use If the OL symbol appears on the LCD it means the reading is outside the measuring range Please keep to the permitted measuring ra...

Страница 4: ...f Approx 20 minutes Operating environment 10 50 C 14 122 F 0 80 RH relative humidity Storage environment 20 60 C 4 140 F 0 80 RH relative humidity Dimension 30 H x 60 W x 157 L mm Weight 140g Accessor...

Страница 5: ...last switched on or last reset Indicates the minimum values since the instrument was last switched on or last reset Measure values Air flow Temperature Unit of air flow Temperature Unit Indicates the...

Страница 6: ...ture required for testing 1 When the meter is switched on press the UNIT key to change through the 6 different airflow settings available for measuring 2 Settings are as follows m s meters per second...

Страница 7: ...AP OFF Auto power off deactivated 4 To revert back to the default setting switch the meter off and on again 5 Maintenance 5 1 CLEANING INSTRUCTIONS The meter may be wiped down with a wet sponge or cl...

Страница 8: ...or EU and EEA countries only In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE and its implementation in accordance with national law electrical goods th...

Отзывы: