19
Auto Range Digital Multimeter - USB Interface
DIODE TEST
• Test condition: Forward DC current approximately 1mA. Reversed DC voltage
approximately 1.5V.
• Overload Protection: 250V dc or 250V ac rms
CONTINUITY CHECK
• Description: Continuity beeper
≤
50
Ω.
• Overload Protection: 250V DC or 250V AC rms
TEMPERATURE
• Note: The specifications of temperature don't include thermocouple errors.
• Overload Protection: 250V DC or 250V DC rms.
CAPACITANCE
• Overload Protection: 250V DC or 250V DC rms.
RANGE
RESOLUTION
ACCURACY
-55°C to 0°C
0.1°C
± (5.0% of rdg + 4°C)
1°C to 400°C
0.1°C
± (2.0% of rdg + 3°C)
401°C to 1000°C
1.0°C
± 2.0% of rdg
RANGE
RESOLUTION
ACCURACY
60nF
10pF
± (3.0% of rdg + 20 digits)
600nF 100pF
6
µ
F
1nF
± (3.0% of rdg + 10 digits)
60
µ
F
10nF
300
µ
F
100nF
±(5.0% of rdg + 10 digits)
RANGE
RESOLUTION
ACCURACY
1V
0.001V
1.0% uncertainty
RANGE
RESOLUTION
TEST CONDITION
600
Ω
0.1
Ω
Open circuit voltage: approx. 0.5V
5163440K_Instructions.qxd 18/09/2009 10:32 Page 19