48
RS-485 connection is very long (longer than 200M), it’s not
recommended to use high speed connection (greater than
2400bps).
-
Data Bits: Select data bits of RS-485 connection.
-
Parity: Select parity bit: odd, even, or space.
-
Stop Bit: Select stop bit: 1 or 2.
-
Home/Up/Down/Left/Right: Input the command string
used to move pan-tilt camera cradle to home or
up/down/left/right position. You can click ‘Test’ button to
send command string for testing.
-
Command 1 ~ 5: You can define extra pan-tilt camera
cradle control strings here by giving it a name (Command
Name) and command string (Hexadecimal Message). You
can also click ‘Test’ button to send command string for
testing.
When you finish with above settings, click ‘Apply’ button to save changes.