EdilKamin WINDO2 75 Скачать руководство пользователя страница 2

2

ENGLISH

The undersigned EDILKAMIN S.p.a. with head of

fi

 ce 

headquarters at Via Vincenzo Monti 47 - 20123 Milan - 
Italy - VAT IT00192220192

Declares under its own responsability as follows:
The below listed wood burning products comply 
with EU Regulation 305/2011 and the harmonized 
European Standard EN 13229:2001+A1:2003+A2:20
04+AC:2006+AC:2007

Wood Fireplace trademark EDILKAMIN, 
called WINDO2 75 

Year of manufacture:    Ref. Data nameplate                     
Declaration of Performance 
Windo2 75 - DoP n. EK 143 

The liability of Edilkamin is limited to the product sup-
ply only.

Introduction    

3

Introduction    

3

Safety information    

4

Safety information    

4

Technical data   

Technical data   

Dimensions       

Dimensions       

Preparation and packaging  

7

Preparation and packaging  

7

Installation 

9

Installation 9

Instructions for use 

15

Instructions for use 

15

Maintenance 

18

Maintenance 18

In the event of problems 

19

In the event of problems 

19

TABLE OF CONTENTS

Содержание WINDO2 75

Страница 1: ...WINDO2 75 WOOD FIREPLACE UK Installation use and maintenance ...

Страница 2: ...ademark EDILKAMIN called WINDO2 75 Year of manufacture Ref Data nameplate Declaration of Performance Windo2 75 DoP n EK 143 The liability of Edilkamin is limited to the product sup ply only Introduction 3 Introduction 3 Safety information 4 Safety information 4 Technical data 5 Technical data 5 Dimensions 6 Dimensions 6 Preparation and packaging 7 Preparation and packaging 7 Installation 9 Install...

Страница 3: ...om www edilkamin com After unpacking the product check the condition and completeness of the contents In the event of error immediately contact the retailer where the purchase was made providing him with a copy of the warranty booklet and the sales receipt The appliance must be installed and operated in compliance with local and national law and European regulations For the installation and for an...

Страница 4: ...C OR ANYTHING OTHER THAN DRY WOOD IN THE FIREPLACE You risk dirtying the product fires in the chimney flue and causing damage to the environment use of fuel different from the recommended fuel DO NOT OVERLOAD THE FIREPLACE There is a risk of deformation with risks for people in the event of attempted fixing up and irreversible changes to the colour of the paint on the metal parts Edilkamin or the ...

Страница 5: ...raught 5 12 Pa Fuel consumption 3 2 kg h Heatable volume 315 m3 Smoke outlet pipe diameter 200 mm Air intake pipe diameter 140 mm Weight including packaging 336 kg TECHNICAL DATA FOR THE DIMENSIONING OF THE FLUE WINDO2 75 Nominal power Temperature of fumes on exit from the discharge pipe 299 C Minimum draught 5 Pa Fume flow capacity 13 2 g s GENERAL INFORMATION Edilkamin proposes the following 2 m...

Страница 6: ...ns cm 75 x 44 5 h feet max cm 10 WINDO2 75 dimensions cm Ø 14 cm air combustion Ø 14 cm intake warm air Ø 14 cm intake warm air warm air Ø 14 cm without kit Air difffuser Ø 10 cm with kit Air difffuser Ø 20 cm smoke outlet 63 32 5 37 24 5 36 55 63 94 41 30 14 22 150 56 5 53 39 1 5 ...

Страница 7: ...ey can be adjusted to maximum 10 cm PREPARATION AND UNPACKING The materials composing the packaging are not toxic The materials composing the packaging are not toxic or harmful therefore no particular disposal processes or harmful therefore no particular disposal processes are required are required Storage disposal and any recycling is the responsi Storage disposal and any recycling is the respons...

Страница 8: ...oor Description Number in the figure below Quantity Use Fireplace 1 1 Anti corrosion discs 2 2 dispose of with domestic waste Protective glove 3 1 for hinged type opening of the hearth door R2 unions 4 2 for ducting in the version without ventilation kit Upper Deflector made of refractory material 5 1 to be installed in the product Counterweights 6 4 Counterweights plates for making the door self ...

Страница 9: ...OF THE PLATES ON THE DOOR FRAME P INSTALLATION without plates standard with plates added during the installation phase NOT self closing self closing Assembly of internal refractories Assembly of internal refractories The fireplace is delivered without the internal The fireplace is delivered without the internal refractories installed to prevent breakages refractories installed to prevent breakages...

Страница 10: ...itted together have a mainly vertical development no section should have a reserve slope have an inner section preferably circular and however with a ratio between sides lower than 1 5 complete the roof with the appropriate chimney stack direct discharge is forbidden on walls or towards closed spaces even if outdoors be created with materials with a fire reaction class A1 pursuant to UNI EN 13501 ...

Страница 11: ...amber for unburned fuel and any condensate be at least category T400 with an adequate resistance to soot fireIf pre existing it must be cleaned to avoid risk of fire THE CHIMNEY STACK THE CHIMNEY STACK must be wind proof have an internal section equivalent to that of the chimney flue and passage section outlet equal to at least double the inner passage of the chimney flue for paired chimney flues ...

Страница 12: ...ient air to pass through membranes to enable the ambient air to pass through them them The ambient air heats up and rises by convection The ambient air heats up and rises by convection along the air gap behind the hearth and emerges hot along the air gap behind the hearth and emerges hot from the vents from the vents 2 2 positioned on the casing s cover positioned on the casing s cover The length ...

Страница 13: ...l insulated case they must be well insulated The channels must have a maximum length of 4 5 m The channels must have a maximum length of 4 5 m each each The said length must be decreased by 1 2 m for The said length must be decreased by 1 2 m for every curve and for every nozzle consequent to the consequent load loss The following kits are available to channel hot air Kit one bis solo locale camin...

Страница 14: ...prevent heat build up The gather hood can be made with fireproof panels plasterboard can be made with fireproof panels plasterboard or gypsum slabs during construction the hot air or gypsum slabs during construction the hot air ducting kit must be mounted as described above ducting kit must be mounted as described above The interior of the gather hood should be aerated The interior of the gather h...

Страница 15: ...ds the left Grip the handle Grip the handle N N and slide the door upwards or and slide the door upwards or downwards downwards Use the protective glove provided if the product is hot Use the protective glove provided if the product is hot If the lever is not properly If the lever is not properly positioned entirely to the right positioned entirely to the right the door will not open in the the do...

Страница 16: ... air entering the combustion chamber 1 2 3 4 Position Description Effect 1 Ignition maximum power Primary air sent entirely to the hearth Primary air sent entirely to the hearth 2 Intermediate position for normal combustion 3 Intermediate position for normal combustion 4 Ember maintenance Post combustion air only All passages for the primary combustion air are Post combustion air only All passages...

Страница 17: ...y flue If the draft is weak initially light a starter fire using If the draft is weak initially light a starter fire using small sized lighting material small sized lighting material Once the correct draft is restored you can add the fuel Once the correct draft is restored you can add the fuel As with all the products the wood product heats and As with all the products the wood product heats and c...

Страница 18: ...lace the removed ash exclusively in non combustible containers bear in mind that the residual embers may containers bear in mind that the residual embers may still re ignite 24 hours after the last combustion still re ignite 24 hours after the last combustion Ceramic glass installed on the products can resist heat up to approx 750 C and is tested and controlled before and after assembly to check f...

Страница 19: ...al containers with fireproof gloves in the event of a fire ask the authorities for help 5 In case of odours check if If first switch on in this case a paint smell is normal If the product is dirty or dusty If you cannot solve the problem contact the retailer or in countries where present the authorised Technical Support Centre The guarantee is only valid if the product defect is proven DISPOSAL At...

Страница 20: ...cod 941283 GB 03 17 F w w w e d i l k a m i n c o m 941283 GB ...

Отзывы: