IntRoDUctIon on InstALLAtIon
Remember that:
•
the stove must be installed by qualified staff who
can issue a Declaration of Conformity
•
all the local and national laws and the European
Standards must be met for installation and use of
the product.
•
In the event of installation in apartment blocks, ask
the administrator’s opinion beforehand.
The general instructions are provided below, taking
the Italian standard UNI 10683 as an example and
guideline.
Checking the suitability of the installation
premises
•
The volume of the room must be over 15 m
3
•
Installation is not permitted in bedrooms,
bathrooms or premises with other products that
take in air for combustion of the same premises
or in premises with an explosive atmosphere. Any
extractor fans, if working in the same environment
or space in which the product is installed, can
cause draft problems.
•
In Italy, check compatibility pursuant to UNI 10683
and UNI 7129 in the presence of gas products.
•
The floor must be able to support the weight of the
stove and the accessories.
Protection from heat and safe distances
All the surfaces of the building adjacent to the stove
must be protected against heating.The insulation
measurements to implement depend on the type of
surface present.
Distance from flammable materials must be:
- 25 cm from the sides ;
- 20 cm from the back
In the event of installation on a floor with inflammable
material and/or combustible material or with insufficient
capacity, you are advised to position the stove on a
steel or glass plate to distribute the load.Ask the retailer
about the optionals.
InstALLAtIon
cHIMneY sYsteM
(Smoke channel, chimney flue and chimney
stack)
This chapter is drafted according to the European
Standards EN 13384, EN 1443, EN 1856, EN 1457. The
installation technicians must take into consideration
these and any other local standards. The manual
should in no way be considered a replacement for the
laws in force.
The stove must be connected to a suitable smoke
discharge that guarantees completely safe evacuation
of the smoke produced by combustion.
Before positioning the stove, you need to check the
chimney flue is suitable.
sMoKe cHAnneL, cHIMneY FLUe
The smoke channel (pipe that connects the smoke
outlet of the fireplace with the chimney flue inlet) and the
chimney flue must, along with other legal provisions:
•
receive the discharge for a single product (multiple
product discharges are not permitted together)
•
have a mainly vertical development
•
no section should have a reserve slope
•
have an inner section preferably circular and
however with a ratio between sides lower than 1.5
•
complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
•
be created with materials with a fire reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
•
be appropriately certified, with an appropriate
fireplace plate, if metal
•
keep the initial section or change it only immediately
above the stove output and not along the chimney
stack