INSTALLATION

INTRODUCTION ON INSTALLATION 

Remember that:

• 

the product must be installed by qualified staff 
who can issue a Declaration of Conformity

• 

all the local and national laws and the European 
Standards must be met for installation and use of 
the product.

• 

In the event of installation in apartment blocks, ask 
the administrator’s opinion beforehand.

We give some general instructions below, however 
these do not obviate the need to comply with local 
regulations and do not affect the installer’s liability for 
the installation.

CHIMNEY SYSTEM 

(Smoke channel, chimney flue and chimney 

stack)

This chapter is drafted according to the European 
Standards EN 13384, EN 1443, EN 1856, EN 1457. The 
installation technicians must take into consideration 
these and any other local standards. The manual 
should in no way be considered a replacement for the 
laws in force.

The product must be connected to a suitable smoke 
discharge that guarantees completely safe evacuation 
of the smoke produced by combustion.

Before positioning the product, you need to check the 
chimney flue is suitable.

SMOKE CHANNEL, CHIMNEY FLUE

The smoke channel (pipe that connects the smoke 
outlet of the fireplace with the chimney flue inlet) and the 
chimney flue must, along with other legal provisions:

• 

receive the discharge for a single product (multiple 
product discharges are not permitted together) 

• 

have a mainly vertical development 

• 

no section should have a reserve slope

• 

have an inner section preferably circular and 
however with a ratio between sides lower than 1.5

• 

complete the roof with the appropriate chimney 
stack: direct discharge is forbidden on walls or 
towards closed spaces, even if outdoors

• 

be created with materials with a fire reaction class 
A1 pursuant to UNI EN 13501 or similar national 
standard

• 

be appropriately certified, with an appropriate 
fireplace plate, if metal

• 

keep the initial section

The hot air can circulate naturally 
(natural convection) or with the aid of a 
ventilation system (AIR DIFFUSER KIT) 
to be purchased separately and applied 
BEFORE completing the installation 
process. 
Contact your retailer for any further 
information.

Checking the suitability of the installation 
premises

• 

The volume of the room must be over 40 m

3

• 

Installation is not permitted in bedrooms, 
bathrooms or premises with other products that 
take in air for combustion of the same premises 
or in premises with an explosive atmosphere. Any 
extractor fans, if working in the same environment 
or space in which the product is installed, can 
cause draft problems.

• 

In Italy, check compatibility pursuant to UNI 10683 
and UNI 7129 in the presence of gas products.

• 

The floor must be able to support the weight of the 
product and the accessories.

protection from heat and safe distances

All the surfaces of the building adjacent to the pro-
duct must be protected against heating.The insulation 
measurements to implement depend on the type of 
surface present.
The product must be installed in accordance with the 
following safety instructions:
- minimum distance of 20  cm from flammable materials 
along the sides and back. 
- no flammable materials may be kept within 80 cm 
from the front of the appliance. 

Electricity lines
There must be no electricity lines in the 
walls or ceiling of the fireplace installation 
area.

Содержание SCREEN EVO 100

Страница 1: ...SCREEN EVO 80 100 WOOD FIREPLACE UK Installation use and maintenance...

Страница 2: ...rd EN 13229 2001 A1 2003 A2 20 04 AC 2006 AC 2007 Wood Fireplace trademark EDILKAMIN called SCREEN EVO 80 100 Year of manufacture Ref Data nameplate Declaration of Performance SCREEN EVO 80 DoP n EK 1...

Страница 3: ...m www edilkamin com After unpacking the product check the condition and completeness of the contents In the event of error immediately contact the retailer where the purchase was made providing him wi...

Страница 4: ...int on the metal parts Edilkamin or the retai ler cannot be held liable cleaning the hot fireplace DO NOT EXTRACT HOT You risk compromising the extractor and possibly smoke in the environment cleaning...

Страница 5: ...13 O2 0 131 0 096 Temperature of fumes 287 198 C Minimum draught 5 12 5 12 Pa Fuel consumption 3 5 3 7 kg h Heatable volume 315 380 m3 Smoke outlet pipe diameter 200 200 mm Air intake pipe diameter 13...

Страница 6: ...NGLISH 75 93 2 17 50 53 93 18 28 17 9 26 19 5 53 10 8 5 50 6 5 75 DIMENSIONS SCREEN EVO 80 cm 13 cm air combustion warm air 14 cm without kit Air difffuser 10 cm with kit Air difffuser 20 cm smoke out...

Страница 7: ...MENSIONS SCREEN EVO 100 cm 75 17 5 2 113 521 18 110 113 15 15 23 28 15 12 19 5 10 53 8 5 50 6 50 75 53 13 cm air combustion warm air 14 cm without kit Air difffuser 10 cm with kit Air difffuser 20 cm...

Страница 8: ...intake or fumes outlet to handle the appliance it is easy to put them out of alignment in this way PREPARATION AND UNPACKING The materials composing the packaging are not toxic or harmful therefore n...

Страница 9: ...ting for the version without ventilation kit Lever for air limitation 1 regulates the combustion air flow Connector for combustion air intake pipe to be positioned behind or below 1 for connecting the...

Страница 10: ...ect execution may cause problems with the product INVERSION OF THE HEARTH DOOR SCREEN leaves the factory with the hearth door hinged on the left To invert the opening direction follow the procedure gi...

Страница 11: ...1 ENGLISH INSTALLATION A B A B A B C A D D1 B C A D1 3 Unscrew dowel C lower pin B and upper door stop D with its plug D1 4 Refit lower dowel C lower pin B and upper door stop D D1 on the opposite sid...

Страница 12: ...point 2 unscrew and remove the left profile E This will no longer be used as it will be replaced with the new one provided with the product with a slot for the latch 6 Unscrew and remove the profile...

Страница 13: ...the door opening latch G unscrewing the screw The transformation is shown in the diagram below from point 1 to point 3 Screw the latch onto the left side 8 Detach the pre cut upper profile H from the...

Страница 14: ...scription of the optional thermostatic valve installation procedure open the hearth door Fig 1 Remove it to make the job easier by sliding it off the pins fig 2 and details on door inversion instructi...

Страница 15: ...ensor cable position the assembled thermostatic valve in its compartment and route the sensor cable through the opening in the plate Fig 7 screw the sensor mounting plate F Fig 7 into the provided hol...

Страница 16: ...lug is accessible once the installation is complete if you intend to install the Air Diffuser ducting system Secure the bottom of the base to the fl oor with 8 mm steel anchor bolts to prevent it from...

Страница 17: ...n 1 5 complete the roof with the appropriate chimney stack direct discharge is forbidden on walls or towards closed spaces even if outdoors be created with materials with a fire reaction class A1 purs...

Страница 18: ...t least category T400 with an adequate resistance to soot fireIf pre existing it must be cleaned to avoid risk of fire THE CHIMNEY STACK must be wind proof have an internal section equivalent to that...

Страница 19: ...uced by the firebox is introduced into the rooms to be heated through the delivery vent connected to the opening on the casing cover through a 14 cm aluminium pipe The length of the ducting depends on...

Страница 20: ...kits are available to channel hot air Kit one bis solo locale caminetto Kit two bis Kit three bis Furtherdetailsareprovidedintheassemblyinstructions supplied with the kit itself Circulation with Kit A...

Страница 21: ...ith fireproof panels plasterboard or gypsum slabs during construction the hot air ducting kit must be mounted as described above The interior of the gather hood should be aerated by exploiting the flo...

Страница 22: ...is an optional accessory It fills in the gap remaining between the firebox s frame and the cladding itself If purchased it is sold in a single package containing surround bolts To install it proceed a...

Страница 23: ...combustion air supply to the chamber adjust the air regulator with the provided removable lever Position Description Effect 1 Ignition maximum power Primary air sent entirely to the hearth 2 Intermed...

Страница 24: ...settling noise which is not a reason for dispute Instructions for use FUEL The product was designed to burn wooden logs or sawdust briquettes Use dry wood logs max humidity 20 Use logs The use of dam...

Страница 25: ...anging or forcing it Glass since it is not flexible can break Removing ash Remove the ash with a scoop or ash cleaner Place the removed ash exclusively in non combustible containers bear in mind that...

Страница 26: ...tools and only touch metal containers with fireproof gloves in the event of a fire ask the authorities for help 5 In case of odours check if If first switch on in this case a paint smell is normal If...

Страница 27: ......

Страница 28: ...cod 941342 GB 03 17 C w w w e d i l k a m i n c o m 941342 GB...

Отзывы: