EdilKamin PELLKAMIN 8 EVO Скачать руководство пользователя страница 59

59

ENGLISH

USER/INSTALLER

IN THE EVENT OF PROBLEMS

MESSAGE

PROBLEM

SOLUTION

A01

displays when the combustion 
air intake is below the set level

•  Check that the combustion chamber door is closed
•  Check the regular maintenance of the product
•  Check that smoke discharge and combustion air 

ducts are clean.

A02

displays when the logic board 
is not detecting the right fumes 
fan speed

•  Contact the technician 

A03 

displays when the 
thermocouple detects a fume 
temperature lower than the set 
value and interprets this as the 
absence of flame

•  Check that there are pellets in the tank
•  Contact the technician

A04

displays when ignition times 
out unsuccessfully

There are two possibilities:
NO flame:
• Check that the burning pot is seated properly and clean
• Check that there are pellets in the tank and burning pot
• Try switching it on with a solid ecological igniter (contact 
the technician beforehand and follow the instructions of 
the igniter supplier very carefully).
The operation must be regarded purely as a trial under the 
technician’s guidance.

A05

Shutdown due to air flow rate 
sensor breakage

•  Contact the technician

A06

displays when the logic board 
determines that the fumes 
thermocouple is broken or 
disconnected  

•  Contact the technician

A07

Shut-down due to exceeding 
maximum fumes temperature.

•  Check the type of pellet (contact the technician if in 

doubt)

•  contact the technician

A08

Switching OFF due to excessive 
overheating of the product

• see 

A07

A09

Shutdown due to gearmotor fail-
ure.

•  Contact the technician

A10

Switching OFF due to circuit 
board overheating.

•  Contact the technician

A11

Switching OFF due to the inter-
vention of the safety pressure 
switch.

•  Ensure the product and flue are clean 
•  Contact the technician

Содержание PELLKAMIN 8 EVO

Страница 1: ...EN Installation use and maintenance page 2 PELLKAMIN 8 EVO WOOD PELLET INSERT...

Страница 2: ...SERIAL NUMBER Nameplate reference Performance declaration PELLKAMIN 8 EVO DoP EK n 201 Ref data tag plate Nameplate reference And also declares that the PELLKAMIN 8 EVO wood pellet insert satisfies th...

Страница 3: ...ion and for anything not specifically indicated in the manual observe local regulations The diagrams provided in this manual are for illustration purposes only they do not always strictly refer to you...

Страница 4: ...The product may be soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT Risk of damage to the cl...

Страница 5: ...5 ENGLISH DIMENSIONS USER INSTALLER PELLKAMIN 8 EVO cm The frame is optional 76Lx52h 49 Smoke outlet 8 cm 73 3 49 6 4 2 49 Combustion 4 cm 49 73 5 9 Combustion 4 cm 8 28...

Страница 6: ...6 ENGLISH DIMENSIONS OPTIONAL USER INSTALLER PELLKAMIN 8 EVO cm Hatch loading Tray loading 75 7 60 49 57 5 55 52 75 7 49 49 7 Optional RACK mm 1 0 5 2 5 5 63 4139 387 92 140 355 1 5 0 45 min 55 max 74...

Страница 7: ...lation Class A G A TECHNICAL DATA FOR SIZING THE FLUE which must in any case satisfy the requirements in this sheet and the installation instructions for the product Nominal power Reduced power Fumes...

Страница 8: ...4 2 1 CC 2 5 yes F 2 7 0 up to 2022 F 2 7 0 from 2022 NO NO with distance control option yes F 3 1 0 up to 2022 F 3 1 0 from 2022 Contact details Name and address of the manufacturer www edilkamin co...

Страница 9: ...ulatory fashion Always move the stove vertically with suitable equipment and in compliance with safety regulations Do not turn the package over and handle all parts requiring installation with care In...

Страница 10: ...INGS NOT ALWAYS REFERRING TO THE SPECIFIC MODEL TO REMOVE THE STOVE FROM THE PALLET TO REMOVE THE STOVE FROM THE PALLET Remove the screws Remove the screws DO NOT REMOVE THE PRODUCT FROM THE PALLET BE...

Страница 11: ...anomalies The packaging comprises a single item containing the following INSTALLER INDICATIVE DRAWINGS NOT ALWAYS REFERRING TO THE SPECIFIC MODEL A B NOTE The frame rack Hatch loading kit with chute a...

Страница 12: ...3 The floor must be able to bear the weight of the product and its accessories Level the appliance The appliance may not be installed in a bedroom bathroom or in the same room as other equipment which...

Страница 13: ...5 terminate at roof level with a proper chimney pot the flue may not discharge directly from the wall or into an enclosed space even if the space in question is open to the sky be made of material rat...

Страница 14: ...imney pot receiving the fumes from the solid fuel appliance or that from the higher storey must be at least 50 cm higher than the other it must extend beyond the back flow zone in Italy refer to UNI 1...

Страница 15: ...lectrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The power line must be of ad...

Страница 16: ...countersunk screws the screw head must not protrude more than 2 mm from the base plate The customer can make other holes being careful not to do so in line with the guides Z Fig 4 Fit the flue not sup...

Страница 17: ...17 ENGLISH INSTALLATION INSTALLER BE CAREFUL REMOVE THE PART AS SHOWED BELOW WITHOUT OPTION Tray loading HATCH LOADING...

Страница 18: ...e insert is positioned These grilles prevent the accumulation of heat inside which is then used to help heat the room of installation INDICATIVE DRAWINGS NOT ALWAYS REFERRING TO THE SPECIFIC MODEL Int...

Страница 19: ...one another but spaced at least 1 cm apart to enable air another but spaced at least 1 cm apart to enable air to flow and prevent heat build up to flow and prevent heat build up The gather hood The g...

Страница 20: ...local regulations envisaging for example products with the following envisaging for example products with the following characteristics characteristics diameter 6 mm diameter 6 mm length 3 4 cm length...

Страница 21: ...it will go F G USER INSTRUCTIONS Each time the insert is removed a security system cuts off the power supply Should the insert be removed involuntarily during ignition operation or while switching off...

Страница 22: ...ng the power EASY TIMER manual automatic is used to pro gramme the switch ing off on after a set number of hours maximum 12 hours OPTIONAL CONNECTIONS The technician can supply on request external the...

Страница 23: ...igures user of the product operations not protected by password installer operations with dedicated password because any errors can jeopardise the product s operations and SECURITY Edilkamin technical...

Страница 24: ...t switch on operation the language is not set the adjacent language selection screen will ap pear Choose the language with the buttons and confirm with OK REMOTE CONTROL POWER SAVING After 20 of non u...

Страница 25: ...mbol Appears after a certain number of hours of operation The relative function is active EasyTimer Crono EasyTimer and Crono cannot be activated simultaneously C F Indicates the unit of measurement o...

Страница 26: ...e the product s air power depends on the room temperature or is set by the user Setting Indicates that the remote control is in the setting mode The settable value will appear in the bottom bar Digits...

Страница 27: ...button on the remote control or due to an external contact timer telephone dialler From the OFF page press the ON OFF button for 3 seconds to access the ON page ON STATUS The product is active and ca...

Страница 28: ...ff Simply wait without taking any action During the switch off the display will show the word OFF If time scheduling is active the status bar will alternately show 3 seconds the status and the program...

Страница 29: ...ing the and buttons For example press any button and the display will activate then press the button For example press any button and the display will activate then press the button flame symbol The s...

Страница 30: ...ducted fans 2 and 3 FAN ADJUSTMENT The setting can be made with the stove turned OFF or ON If the backlight is switched off it can be activated by pressing any button Pressing the or button will make...

Страница 31: ...our intervals By activating the Easy Timer function with the product off the user sets the switch on time Pressing the OK button or after 5 without pressing any button the countdown will start with 5...

Страница 32: ...wise it works with the power Pressing the button allows for switching from Temperature Timer to Power Timer and vice versa Pressing the button activates or deactivates the timer pre programmed from th...

Страница 33: ...items appear in the following order 01 STAND BY 02 PELLET LOAD 03 CHRONO PROG TIMER 04 T1 T2 05 DATE HOUR TIME 06 C F 07 LANGUAGE 08 DISPLAY 09 INFO 10 SOFTWARE 11 DATA 12 ALARMS 13 AUGER MOT ON OFF...

Страница 34: ...ature set point is reached To access the function from the main menu as indicated in the Menu section above press the MENU button The menu items can be scrolled with the and buttons and the item can b...

Страница 35: ...es the function and the display will propose to choose how many minutes must pass before the devices switches off in stand by mode es 5 minutes The and buttons can be used to modify the time and the b...

Страница 36: ...ctivated ON if active PELLET LOAD Allows you to load pellets after the screw feeder has emptied Useful for the technician during the initial start up Available only in the OFF status Any attempt to ac...

Страница 37: ...ONS USER To access the function from the main menu as indicated in the Menu section above press the MENU button The menu items can be scrolled with the and buttons and the item can be entered with the...

Страница 38: ...that day and confirm with the button The cursor rectangular and 2 pixels wide positions itself on 00 00 The time at the top RH shows the start of the time slot The word SET appears with the pre set le...

Страница 39: ...els OFF P1 and P5 After reaching 23 30 you must go backwards If you shift by pressing and holding the and buttons for more than 2 you copy the previous level onto the next level with a 1 2 h frequency...

Страница 40: ...Only if stand by is on the product switch on at the reached temperature Pressing the button briefly allows you to exit the programming but the programme will not activate To activate it you must brief...

Страница 41: ...line T1 is the lowest temperature T2 the highest Use the and buttons to move to set point T2 setting Modify the values with the and buttons and confirm with the button Pressing the button automaticall...

Страница 42: ...hen flash If the product is connected to the cloud the date and time can be set from the Web and in the menu after accessing the function a message like Date Time from Web will appear If the product i...

Страница 43: ...value on the second line You can switch from C to F using the and buttons and then confirm with the button and exit Pressing the OK button automatically takes you back to the first level USER INSTRUCT...

Страница 44: ...ss the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the following button After en...

Страница 45: ...n The technician understands the diagnostic meaning of the messages and values and may ask you to read them to him her if you experience problems Exit with the following button To access the function...

Страница 46: ...th the following button USER INSTRUCTIONS To access the function from the main menu as indicated in the Menu paragraph above press the MENU button The menu items can be scrolled with the and buttons a...

Страница 47: ...ons The alarms are arranged from the most recent to the oldest SCREW FEEDER ON OFF FOR THE TECHNICIAN ONLY ON INDICATION OF THE AFTER SALES DEPARTMENT PELLET LEVEL SENSOR FOR THE TECHNICIAN ENABLING E...

Страница 48: ...en modify the correction value with the and buttons Use the button to exit and return to the Technical Menu You must enter with the installer password 1111 and access the installer parameters settings...

Страница 49: ...n scroll the Technical Menu items with the and buttons until you reach PELLET TYPE You can enter the Pellet Type setting with the following button and modify the value with the and buttons Use the but...

Страница 50: ...EP MAX ON CHIMNEY SWEEP FUNCTION ONLY WITH THE PRODUCT ON It can be used to conduct the requested checks agreed upon with the technician Scroll between the Nominal Max or Minimum Min function using th...

Страница 51: ...uttons and modify the value with the and buttons If you entered the Technical Menu with the installer password only the installer parameters will appear otherwise all the other parameters will be show...

Страница 52: ...mmand to the product the remote control or smartphone will once again resume control of the product The display will ONLY appear if the product is controlled via the SAVE PANEL FUNCTIONS To switch on...

Страница 53: ...53 ENGLISH Below please find a description of when the LEDS will light up USER INSTRUCTIONS SAVE PANEL USER 3 4 2 1 3 4 2 1 3 4 2 1...

Страница 54: ...falls 4 3 Scrape the burning pot with the scraper and clean out any obstructed holes 4 If necessary clean the glass when cold using a dedicated product e g Glasskamin which your dealer should have USE...

Страница 55: ...ith brush Vacuum the hose located near the electrical resistan ce 5 Remove the ceiling 6 and tip the residue into the ash drawer N B reposition the ceiling with the arrow pointing outwards Clean the c...

Страница 56: ...icial dealers and service can be found on www EDILKAMIN COM Using non original spare parts may damage the appliance and relieves Edilkamin of all liability for damage resulting therefrom DISPOSAL At t...

Страница 57: ...during the various operating stages This implies normal expansion movements This implies normal expansion movements These expansions may cause slight settling noises These expansions may cause slight...

Страница 58: ...cleaned regularly as explained above ignition may involve a slight detonation If white smoke forms in the combustion chamber for a long time disconnect the mains supply and wait 30 minutes before ope...

Страница 59: ...ere are pellets in the tank and burning pot Try switching it on with a solid ecological igniter contact the technician beforehand and follow the instructions of the igniter supplier very carefully The...

Страница 60: ...TION A12 Room temperature probe failure The product is operating in manual mode Contact the technician A14 Ducting room temperature probe if present fault The product is operating in manual mode Conta...

Страница 61: ...operation The product is working but it must be serviced by an authorised Edilkamin technician LACK OF COMMUNICATION In case of a prolonged lack of communication between the stove and the remote cont...

Страница 62: ...l sensor is installed and has been activated When the level sensor intervenes the circuit board emits a single beep in any switch on or work status and the moving reserve symbol will appear on the dis...

Страница 63: ...be restarted After reloading the pellets the stove must be restarted manually If the pellets are reloaded and there is an ignition request coming from the timer the stove will restart If the sensor i...

Страница 64: ...cod 942237 GB 10 21 A w w w e d i l k a m i n c o m 942237 GB...