EdilKamin MYA ECO Скачать руководство пользователя страница 21

- 21 

-

ENGLISH

CHECK LIST

To be integrated with a complete reading of the technical specifications

Positioning and installing

• 

First ignition performed by authorised CAT who released the guarantee certificate

•  

Room ventilation

•  

Only the stove outlet passes through the smoke channel/chimney flue

•  

The smoke channel has: a maximum of 3 curves, 

 

 

                         a maximum 2 horizontal metres 

• Chimney pot that is high enough to avoid downdraft areas

• The discharge pipes are made of a suitable material (stainless steel is recommended)

• When using any flammable materials (e.g. wood), all precautions have been taken to prevent a fire hazard

Use

• Good quality, dry pellets are used

• The chimney pot and ash compartment are clean and well positioned

• The door is closed properly

• The combustion chamber is inserted properly into the relevant compartment

REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION

Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.

OPTIONAL

TELEPHONE COMBINER FOR REMOTE IGNITION

The stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the stove via the 

optional cable.

KIT FOR A SMOKE OUTLET CONNECTION ON TOP

PIPE COVER KIT FOR A SMOKE OUTLET CONNECTION ON TOP

CLEANING ACCESSORIES

Ash vacuum cleaner 

without motor 

(code 275400)

User for cleaning 

the hearth

GlassKamin

(code 155240)

Used for cleaning the 

ceramic glass

INFORMATION FOR USERS

In accordance with Art. 13 of the Legislative Decree No. 151, dated 25 July 2005, “Implementation of Directives: 2002/95/EC, 

2002/96/EC and 2003/108/EC, pertaining to the reduction of hazardous substances used in electrical and electronic equipment, 

as well as disposal of waste”. The crossed-out wheeled bin symbol shown on the equipment or on the packaging indicates that 

the product must be disposed of separately at the end of its useful life. Therefore, at the end of the equipment’s useful life, the 

user must hand in the equipment to suitable collection facilities for electrical and electronic waste, or return it to the retailer 

when a new, equivalent appliance is purchased in a ratio of one to one.

Содержание MYA ECO

Страница 1: ...1 MYA ECO UK Installation use and maintenance...

Страница 2: ...ng from the use of this product the proof of purchase tag necessary for identifying the insert is located on the top of the package in the warranty booklet found inside the firebox on the ID plate aff...

Страница 3: ...t do not touch without wearing the thermal glove Do not place anything which is not heat resistant near the stove NEVER use liquid fuel to ignite the stove or rekindle the embers Do not obstruct the v...

Страница 4: ...ustione 58 96 56 58 56 5 5 12 18 5 29 8 cm uscita fumi 4 cm aria combustione 10 Combustion air 40 mm FRONT BACK SIDE SYSTEM Smoke outlet 80 mm THE STOVE COMES IN FOUR STYLES Sides in white glass top i...

Страница 5: ...re level in the combustion chamber and smoke temperature The detection of and subsequent optimisation of these two parameters is continuous in order to correct operation anomalies in real time The LEO...

Страница 6: ...ve on and off and controls its operation based on defined parameters VACUUM GAUGE positioned on the smoke extractor which detects the vacuum value compared to the installation environment in the combu...

Страница 7: ...l must be protected with an anti insect netting that does not reduce the 12 cm through passage INSTALLATION MOKE OUTLET The stove must have its own smoke outlet the smoke can not be discharged into a...

Страница 8: ...profiles on the back G fig 6 Take the glass sides off H fig 7 and remove the protection Remove the rubber pads fixed under the fixing brackets up per and lower for the glass sides I fig 8 Remove ever...

Страница 9: ...des Remove the supported glass top A fig 1 Open the door and remove the galvanised panel B fig 2 Slacken the wing nuts at the lower and upper ends on the inside of the left side C D fig 3 4 Close the...

Страница 10: ...fig 9 and fix it using the clamp slackened previously Remove the cast iron cap N fig 10 resting on the top and fit the flue pipe outlet P fig 10 from the side of the stove Position the two plating clo...

Страница 11: ...lows Fit the pipe cover fixing bracket A fig 1 using the screws 4 2x6 5 supplied to the two plating closers A1 fig 1 at the holes formed Put a short pipe cover element on from the front B fig 2 and a...

Страница 12: ...2 ATTENTION use the glove supplied when filling the stove whilst it is run ning and therefore is hot fig 1 fig 2 press If pellets with different characteristics are used the stoves must be recalibrat...

Страница 13: ...rol on stand by to remote control on to increase decrease the various regulations A to select Automatic function M to select Manual function and access the control and programming menus The display al...

Страница 14: ...nual operation With the stove working press the key M on the remote control once The display will show the word POWER P specifying the power at which the insert is working Press the keys or to increas...

Страница 15: ...a programme for each day of the week and if so choosing number of interventions and at what times Should you make an error during programming you can leave the programme without saving As you press a...

Страница 16: ...screen appears then use the key to take the figure to the value equal to the Kg of pellets loaded 15 kg in the above example 4 press the M key to confirm 5 press the key to exit After having completed...

Страница 17: ...the inside of the fire box fire grate and space around the fire box into which the ash falls Remove the fire box 1 fig A and remove any encrustation using the brush provided clearing any clogging in t...

Страница 18: ...check loosening of the feed screw gear motor assembly Replace the door seal Functionality test load the feed screw ignite let it run for 10 minutes and shutdown If the stove is used very often it is...

Страница 19: ...ensor detects a fault Problem Shutdown for smoke extraction speed fault detection Actions Check smoke extractor function devolution sensor connection and board DEALER Check smoke channel for dirt Veri...

Страница 20: ...possible to launch an automatic search for a product manually simply carry out the following operations after having already put the batteries into the radio control Go close to the product s antenna...

Страница 21: ...OPTIONAL TELEPHONE COMBINER FOR REMOTE IGNITION The stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the stove via the optional cable KIT...

Страница 22: ......

Страница 23: ......

Страница 24: ...24 w w w e d i l k a m i n c o m cod 941252 GB 07 16 C...