7)    Signalling: 

smoke °C/high.

       Problem:  

turns off due to exceeding maximum smoke temperature.

       Actions: 

• Check the pellet type

 

• Check for anomalies with the smoke extraction motor

 

• Check to see if there are any obstructions in the smoke channel

 

• Check correct installation

 

• Gear motor faulty (CAT)

 

       

8)   Signalling:  

Check button 

(signals an anomaly on the emergency button) 

      Actions: 

• check maintenance status of the button and its board connection cable (DEALER).

9)  Signalling: 

“Battery check”

       Problem: 

The insert does not stop but the error appears on the display.

       Actions: 

• The buffer battery of the control board needs changing (DEALER). 

 

Remember that this component is subject to regular wear and so it is not covered by the guarantee.

10)

 

Signalling: 

ALARM - HIGH CURRENT:

 Activated when anomalous, excessive current absorption is detected on the 

gear motor..

       Actions:

  

Check functioning (CAT): gear motor - Electrical connections and electronic board.

11)

 

Signalling: 

ALARM - LOW CURRENT:

 Activated when anomalous, insufficient current absorption is detected on the 

gear motor.

       Actions:

  

Check functioning (CAT): gear motor - pressure switch - tank thermostat - electrical connections and electro

-

nic board

12) Problem:  

Remote control not working

       Actions: 

• Move closer to the stove 

 

• check the battery and if necessary, replace it.

 

• Synchronisation with automatic search on activation: when you put the batteries into the radio control a 

radio channel search phase will start up automatically, and it will subsequently connect to the product de

-

tected. So that this occurs correctly, make sure to switch the product on before inserting the batteries in the 

radio control, and stay in the vicinity of the antenna in order to achieve radio coverage with certainty. 

 

• Synchronisation with automatic search and manual activation - it is possible to launch an automatic search 

for a product manually, simply carry out the following operations after having  already put the batteries into 

the radio control: 

 

- Go close to the product’s antenna and make sure it is connected to the electricity supply. 

 

- With the display switched off (standby) hold the 0/I key down for 10”.

 

- After 10” a “NETWORK SEARCH” message appears on the display, then release the o/I key, as this means 

that the automatic search has been activated.

 

- Automatic tuning of the radio channel will occur within a few seconds. 

13)  Problem:  

During ignition, the differential switch trips (DEALER):

       Actions:  

• Check the condition of the ignition coil, the electrical system, and the electrical components.

14) Problem: 

Outgoing air not hot:

       Actions:  

• Check that the fan is working.

NOTA 1

All signals/warnings remain shown until you intervene on the remote control, by pressing the button 

.

Do not use the insert before having eliminated the problem.
NOTA 2

Once 1000 kg of pellets have been consumed or some other value set by the CAT during the first ignition, the display 

flashes a message that reads “maintenance”.

The stove works, but you must call the Dealer out to perform extraordinary maintenance.
NOTA 3   

If due to the quality of pellets or particularly critical installation, the stove becomes clogged earlier, the message

“CALL SERVICE” will appear. Proceed as per “Mainten.” instructions.

N.B.:

The combustion chambers and smoke ducts connected to the solid fuel appliances must be cleaned once a year (check

if your country has specific legislation covering this).

Failure to regularly check and clean increases the likelihood of a fire in the chimney pot.

IMPORTANT!!!

In the case of a fire in the stove, in the flue or in the chimney, proceed as follows:

- Disconnect the power supply

- Use a carbon dioxide (CO

2

) extinguisher 

- Call the fire brigade

DO NOT ATTEMPT TO PUT THE FIRE OUT WITH WATER!

After the event, have the appliance checked by an authorised Service Centre and have an authorised technician check the flue.

Содержание MYA ECO

Страница 1: ...1 MYA ECO UK Installation use and maintenance...

Страница 2: ...ng from the use of this product the proof of purchase tag necessary for identifying the insert is located on the top of the package in the warranty booklet found inside the firebox on the ID plate aff...

Страница 3: ...t do not touch without wearing the thermal glove Do not place anything which is not heat resistant near the stove NEVER use liquid fuel to ignite the stove or rekindle the embers Do not obstruct the v...

Страница 4: ...ustione 58 96 56 58 56 5 5 12 18 5 29 8 cm uscita fumi 4 cm aria combustione 10 Combustion air 40 mm FRONT BACK SIDE SYSTEM Smoke outlet 80 mm THE STOVE COMES IN FOUR STYLES Sides in white glass top i...

Страница 5: ...re level in the combustion chamber and smoke temperature The detection of and subsequent optimisation of these two parameters is continuous in order to correct operation anomalies in real time The LEO...

Страница 6: ...ve on and off and controls its operation based on defined parameters VACUUM GAUGE positioned on the smoke extractor which detects the vacuum value compared to the installation environment in the combu...

Страница 7: ...l must be protected with an anti insect netting that does not reduce the 12 cm through passage INSTALLATION MOKE OUTLET The stove must have its own smoke outlet the smoke can not be discharged into a...

Страница 8: ...profiles on the back G fig 6 Take the glass sides off H fig 7 and remove the protection Remove the rubber pads fixed under the fixing brackets up per and lower for the glass sides I fig 8 Remove ever...

Страница 9: ...des Remove the supported glass top A fig 1 Open the door and remove the galvanised panel B fig 2 Slacken the wing nuts at the lower and upper ends on the inside of the left side C D fig 3 4 Close the...

Страница 10: ...fig 9 and fix it using the clamp slackened previously Remove the cast iron cap N fig 10 resting on the top and fit the flue pipe outlet P fig 10 from the side of the stove Position the two plating clo...

Страница 11: ...lows Fit the pipe cover fixing bracket A fig 1 using the screws 4 2x6 5 supplied to the two plating closers A1 fig 1 at the holes formed Put a short pipe cover element on from the front B fig 2 and a...

Страница 12: ...2 ATTENTION use the glove supplied when filling the stove whilst it is run ning and therefore is hot fig 1 fig 2 press If pellets with different characteristics are used the stoves must be recalibrat...

Страница 13: ...rol on stand by to remote control on to increase decrease the various regulations A to select Automatic function M to select Manual function and access the control and programming menus The display al...

Страница 14: ...nual operation With the stove working press the key M on the remote control once The display will show the word POWER P specifying the power at which the insert is working Press the keys or to increas...

Страница 15: ...a programme for each day of the week and if so choosing number of interventions and at what times Should you make an error during programming you can leave the programme without saving As you press a...

Страница 16: ...screen appears then use the key to take the figure to the value equal to the Kg of pellets loaded 15 kg in the above example 4 press the M key to confirm 5 press the key to exit After having completed...

Страница 17: ...the inside of the fire box fire grate and space around the fire box into which the ash falls Remove the fire box 1 fig A and remove any encrustation using the brush provided clearing any clogging in t...

Страница 18: ...check loosening of the feed screw gear motor assembly Replace the door seal Functionality test load the feed screw ignite let it run for 10 minutes and shutdown If the stove is used very often it is...

Страница 19: ...ensor detects a fault Problem Shutdown for smoke extraction speed fault detection Actions Check smoke extractor function devolution sensor connection and board DEALER Check smoke channel for dirt Veri...

Страница 20: ...possible to launch an automatic search for a product manually simply carry out the following operations after having already put the batteries into the radio control Go close to the product s antenna...

Страница 21: ...OPTIONAL TELEPHONE COMBINER FOR REMOTE IGNITION The stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the stove via the optional cable KIT...

Страница 22: ......

Страница 23: ......

Страница 24: ...24 w w w e d i l k a m i n c o m cod 941252 GB 07 16 C...

Отзывы: