47
ENGLISH
USER
INSTRUCTIONS FOR USE
Shutdown
While the boiler-stove is working pressing the 0/1
key for 2 seconds begins the shutdown process and
“STOPPING” is displayed (for 10 minutes). The turning
off phase includes:
- The interruption of falling pellets
- The circulation of running water.
- Smoke extractor operating at maximum speed.
- Air ventilation
Never pull the plug during shutdown.
N.B. Please note that the circulator runs until the water
temperature drops below 40° C.
Setting the clock
Press the MENU button for 2 seconds and use the
+ and – keys to follow the instructions given on the
display to access the ‘Clock’ menu. This allows you to
set the time on the electronic control board. Then press
MENU and the following data appears in sequence –
this can be adjusted: day, month, year, hour, minutes,
day of the week. When ‘Save?’ appears on the display,
you can check that the settings have been entered
correctly before confirming. Press MENU to save the
information (‘Save OK’ then appears on the display).
Programmer to ignite and shutdown the
thermal stove at various times during the
week.
Press the MENU button on the remote control or
the synoptic panel for 2 seconds to access the time
setting function and press the + key to access the
weekly timer function ‘Program ON/OFF’ will appear
on the display. The timer allows you to set a number of
ignitions and shutdowns per day (up to a maximum of
three), for each day of the week. As you confirm via the
MENU button, one of the following options will appear:
- No Prog. (no program is set)
- Program/daily (a single program is set for every day)
- Program/weekly (a program is set for each day of the
week)
Move from one to the other using the + and – keys.
Use the MENU button to confirm the ‘Daily
program’option and access the selection of the
number of programs (ignition/shutdown) to be set per
day. Use the ‘Program/daily’ option to set the identical
program/s for every day of the week.
The following will be displayed if the + key is pressed:
- No Prog.
- Prog. No. 1 (one ignition and one shutdown per day),
Prog. No. 2 (same as before), Prog. No. 3 (same as
before)
Use the button to show them in reverse order. If the 1st
program is selected, the ignition time is shown.
The display shows: 1 Ignition Hour 10.30; use the +/–
keys to change the hour and press MENU to confirm.
The display shows: 1 Ignition Minutes 10.30; use the
+/– keys to change the minutes and press MENU to
confirm.
In the same way, adjust the shutdown times.
The program is confirmed by pressing the MENU
button when “Saved” appears on the display.
When confirming ‘Program/week’, you will need to
choose the day to which the program is to apply:
1 Mon; 2 Tues; 3 Wed; 4 Thurs; 5 Fri; 6 Sat; 7 Sun
Once you have chosen the day by scrolling through
them with the + and – keys, confirm by pressing MENU
and proceed with the settings of the programs in the
same way as for the ‘Program/daily’, selecting whether
or not to enable a program for each day of the week
and choosing the number and times of interventions.
Should you make a mistake whilst setting the programs
you can exit without saving by pressing the 0/1 key and
‘Saved’ will appear on the display. Should the hopper
run out of pellets, the boiler-stove will block and ‘Stop/
Flame’ will appear.
Pellet reserve warning
The boiler-stove is equipped with an electronic pellet
detection system.
The pellet detection system is integrated into the
electronic control board, allowing the stove to monitor
how many kilos of pellets are left.
This verification is implemented at any point whilst the
stove is in operation mode.
For correct system operation, it is important that the
following procedure is adhered with during the first
ignition (that must be implemented by the DEALER).
Before starting to use the pellet detection system, you
must load and consume a full sack of pellets.
This allows for a brief running-in of the loading system.
Subsequently load 15 kg of pellets.
Then press the ‘reserve’ button once, thereby storing
the data into the memory that 15 kg have been loaded.
From now on the display will show the remaining
pellets as they decrease in kg (15…14...13). Each time
pellets are reloaded you must
enter the quantity. E.g. when loading 15 kg, simply
press the ‘pellet load’ button to enter this into the
memory.
For other quantities, or in the event of an error, you can
specify the quantity using the pellet reserve menu as
follows:
Press the MENU button for 2 seconds to view the
SETTINGS.
Press + or – consecutively to view T. Max exit.
Confirm by pressing MENU and the remaining quantity
of pellets will be dis that being loaded (default
is 15 and can be changed using the +/- keys).
Press the + button to increase the kg value to be
entered, press the -button to reduce the value,
repeatedly press the -button to get 00kg load (R on
the display), which allows deletion of the residual load.
Should the hopper run out of pellets, the boiler-stove
will block and ‘Stop/Flame’ will appear.
Variation feeding pellets (ONLY AFTER
SUGGESTED BY DEALER)
Press and hold the “M” key on the remote control for
two seconds. Scroll through the display instructions
using the “+” and “–” keys, to the description “ADJ-
PELLET”. By confirming this function using the menu
key you can adjust the supply of pellets,
by reducing the set value, you decrease the supply of
pellets, increasing the set value increases the supply
of pellets. This function can be useful in the event that
one changes the type of pellets used, no longer using
those for which the boiler-stove was calibrated, thus
necessitating an adjustment of the load setting.