Shutdown

While the boiler-stove is working pressing the 0/1 

key for 2 seconds begins the shutdown process and 

“STOPPING” is displayed (for 10 minutes). The turning 

off phase includes:

- The interruption of falling pellets

- The circulation of running water.

- Smoke extractor operating at maximum speed.

- Air ventilation

Never pull the plug during shutdown.

N.B. Please note that the circulator runs until the water 

temperature drops below 40° C.

Setting the clock

Press the MENU button for 2 seconds and use the 

+ and – keys to follow the instructions given on the 

display to access the ‘Clock’ menu. This allows you to 

set the time on the electronic control board. Then press 

MENU and the following data appears in sequence – 

this can be adjusted: day, month, year, hour, minutes, 

day of the week. When ‘Save?’ appears on the display, 

you can check that the settings have been entered 

correctly before confirming. Press MENU to save the 

information (‘Save OK’ then appears on the display).

Programmer to ignite and shutdown the 

thermal stove at various times during the 

week.

Press the MENU button on the remote control or 

the synoptic panel for 2 seconds to access the time 

setting function and press the + key to access the 

weekly timer function ‘Program ON/OFF’ will appear 

on the display. The timer allows you to set a number of 

ignitions and shutdowns per day (up to a maximum of 

three), for each day of the week. As you confirm via the 

MENU button, one of the following options will appear:

- No Prog. (no program is set)

- Program/daily (a single program is set for every day)

- Program/weekly (a program is set for each day of the 

week)

Move from one to the other using the + and – keys.

Use the MENU button to confirm the ‘Daily 

program’option and access the selection of the 

number of programs (ignition/shutdown) to be set per 

day. Use the ‘Program/daily’ option to set the identical 

program/s for every day of the week.

The following will be displayed if the + key is pressed:

- No Prog.

- Prog. No. 1 (one ignition and one shutdown per day), 

Prog. No. 2 (same as before), Prog. No. 3 (same as 

before)

Use the button to show them in reverse order. If the 1st 

program is selected, the ignition time is shown.

The display shows: 1 Ignition Hour 10.30; use the +/– 

keys to change the hour and press MENU to confirm.

The display shows: 1 Ignition Minutes 10.30; use the 

+/– keys to change the minutes and press MENU to 

confirm.

In the same way, adjust the shutdown times.

The program is confirmed by pressing the MENU 

button when “Saved” appears on the display. 

When confirming ‘Program/week’, you will need to 

choose the day to which the program is to apply:

1 Mon; 2 Tues; 3 Wed; 4 Thurs; 5 Fri; 6 Sat; 7 Sun

Once you have chosen the day by scrolling through 

them with the + and – keys, confirm by pressing MENU 

and proceed with the settings of the programs in the 

same way as for the ‘Program/daily’, selecting whether 

or not to enable a program for each day of the week 

and choosing the number and times of interventions. 

Should you make a mistake whilst setting the programs 

you can exit without saving by pressing the 0/1 key and 

‘Saved’ will appear on the display. Should the hopper 

run out of pellets, the boiler-stove will block and ‘Stop/

Flame’ will appear. 

Pellet reserve warning

The boiler-stove is equipped with an electronic pellet 

detection system.

The pellet detection system is integrated into the 

electronic control board, allowing the stove to monitor 

how many kilos of pellets are left.

This verification is implemented at any point whilst the 

stove is in operation mode.

For correct system operation, it is important that the 

following procedure is adhered with during the first 

ignition (that must be implemented by the DEALER). 

Before starting to use the pellet detection system, you 

must load and consume a full sack of pellets.

This allows for a brief running-in of the loading system.

Subsequently load 15 kg of pellets.

Then press the ‘reserve’ button once, thereby storing 

the data into the memory that 15 kg have been loaded.

From now on the display will show the remaining 

pellets as they decrease in kg (15…14...13). Each time 

pellets are reloaded you must

enter the quantity. E.g. when loading 15 kg, simply 

press the ‘pellet load’ button to enter this into the 

memory.

For other quantities, or in the event of an error, you can 

specify the quantity using the pellet reserve menu as 

follows:

Press the MENU button for 2 seconds to view the 

SETTINGS.

Press + or – consecutively to view T. Max exit.

Confirm by pressing MENU and the remaining quantity 

of pellets will be dis that being loaded (default 

is 15 and can be changed using the +/- keys).

Press the + button to increase the kg value to be 

entered, press the -button to reduce the value, 

repeatedly press the -button to get 00kg load (R on 

the display), which allows deletion of the residual load.

Should the hopper run out of pellets, the boiler-stove 

will block and ‘Stop/Flame’ will appear.

Variation feeding pellets (ONLY AFTER 

SUGGESTED BY DEALER)

Press and hold the “M” key on the remote control for 

two seconds. Scroll through the display instructions 

using the “+” and “–” keys, to the description “ADJ-

PELLET”. By confirming this function using the menu 

key you can adjust the supply of pellets,

by reducing the set value, you decrease the supply of 

pellets, increasing the set value increases the supply 

of pellets. This function can be useful in the event that 

one changes the type of pellets used, no longer using 

those for which the boiler-stove was calibrated, thus 

necessitating an adjustment of the load setting.

Содержание CHERIE UP H

Страница 1: ...CHERIE UP H EN Installation use and maintenance page 2 PELLET BOILER STOVE...

Страница 2: ...er the company hereby declares that the CHERIE UP wood pellet stove satisfies the requirements of the following European directives 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatib...

Страница 3: ...to follow the instructions in it could cause serious damage to the product and put the safety of those using it at risk OPERATING SEQUENCE follow the instructions for the operations described Product...

Страница 4: ...ay become soiled the flue may catch fire and environmental damage may ensue cleaning the combustion chamber when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT IS HOT You could damage the...

Страница 5: ...5 ENGLISH USER INSTALLER DIMENSIONS DIMENSIONS cm 57 62 115 40 30 11 8 10 6 5 10 16 22 5 valvola sicurezza return 3 4 8 cm smoke outlet 4 cm combustion air delivery 3 4 loading unloading...

Страница 6: ...ng 250 237 230 265 kg TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the requirements of this sheet and the installation instructions for the product Nominal power Reduced power Fum...

Страница 7: ...ic top CHERIE UP GLASS One package containing the stove structure the box with the glass side panels the box with the bottom front panel brackets and small parts the box with the cast iron top CHERIE...

Страница 8: ...te boxes the box with the steel side panels the box with the bottom front panel brackets and small parts the box with the cast iron top 2 1 1 2 5 box with the steel side panels box with the cast iron...

Страница 9: ...d washers for front panel Bottom front panel 4 1 Cast iron top 5 1 1 Remove the pellet tank cover Loosen the wing screws underneath and remove the pellet tank cover by pulling it towards the front Thi...

Страница 10: ...m together 1 shaped polystyrene piece NOTE The curving of the side panels may not perfectly coincide with the curving of the brackets Therefore use your hands to make the panel fit to the bracket befo...

Страница 11: ...eath only on one side NOTE For a better understanding of the position the image below shows the components in a vertical position but we nevertheless recommend that you work in a horizontal position o...

Страница 12: ...the brackets Therefore use your hands to make the panel fit to the bracket before tightening the screws V Do not use any tools so as to avoid the risk of scratching the side panel Once the position o...

Страница 13: ...curing the metal supports STEEL CLADDING screws for fitting the metal supports 3 Fitting of the bottom front panel Open the combustion chamber door using the removable handle Hook the bottom front pan...

Страница 14: ...14 ENGLISH 4 Fitting the top Place the top by slotting it onto the two pins Put the pellet tank cover back on by tightening the wing screws removed at point 1 STEEL CLADDING INSTALLER...

Страница 15: ...x with the bottom front panel brackets and small parts box with the ceramic top 2 1 5 box with the ceramic side panels box with the ceramic top box with the bottom front panel brackets and small parts...

Страница 16: ...side panels at the top and bottom for small bracket h Rubber item screw M6 e 4 For top panel Screw M4x20 f 2 On side panels Cage Nut M4 g 2 On side panels Small adjustment bracket h 2 On side panels...

Страница 17: ...front This will subsequently enable you to position the top and screw on the side panels 2 Assembling and fitting the side panels onto the structure On each of the sides undo the metal support screws...

Страница 18: ...n the shaped polystyrene piece and proceed as follows 2 1 Bring the ceramic side panels together 1 shaped polystyrene piece Position the two adjustment brackets on the ceramic piece and apply the scre...

Страница 19: ...correct position is the point where the bracket profile meets with the metal support Tighten the screws that fix the brackets to the metal profile metal support Position the small bracket with the cag...

Страница 20: ...he side panels Respect the distances between the metal support and the ceramic piece as in the drawing 60 and 70 mm The 70 mm measurement can also be taken from the template position CERAMIC CLADDING...

Страница 21: ...the metal supports POSSIBLE ADJUSTMENTS The brackets allow internal external adjustment The slots allow forward backward adjustment in the top part The small brackets allow forward backward adjustment...

Страница 22: ...en them with the screws fasten it with the M6 Allen screw Open the combustion chamber door using the removable handle Hook the bottom front panel 4 hooks two per side and fasten it with the M6 Allen s...

Страница 23: ...he holes in the structure They are used for any necessary adjustment operations Place the top by slotting it onto the two pins Put the pellet tank cover back on by tightening the wing screws removed a...

Страница 24: ...ox with the glass side panels box with the glass bottom front panel brackets and small parts 2 4 box with the cast iron top 2 4 Description Reference in Figures Quantity Glass side panel 1 2 Brackets...

Страница 25: ...ently enable you to position the top and screw on the side panels Make sure that you disconnect the display cable so as not to break it wing screws GLASS CLADDING 2 Assembling and fitting the side pan...

Страница 26: ...ews for fixing the support onto the bracket metal support silicone washer bracket 3 screws for fixing the support onto the bracket wing screws and washer Position three rubber grommets per side onto t...

Страница 27: ...ble handle Hook the bottom front panel 4 hooks two per side and fasten it with the M6 Allen screw Screw the filler profile onto the structure using the two 4 2x9 5 screws Then hook the assembled side...

Страница 28: ...28 ENGLISH INSTALLER GLASS CLADDING 4 Fitting the top Place the top by slotting it onto the two pins Put the pellet tank cover back on by tightening the wing screws removed at point 1...

Страница 29: ...anel 2 n 1 Cast iron top 3 n 1 As indicated in the Packaging section the stone cladding parts are contained in three separate boxes the box with the side panels the box with the bottom front panel the...

Страница 30: ...y cable so as not to break it wing screws 2 Assembling and fitting the side panels onto the structure On each of the sides undo the metal support screws unhook the metal support and remove it It s not...

Страница 31: ...door using the removable handle Hook the bottom front panel 4 hooks two per side and fasten it with the M6 Allen screw fasten it with the M6 Allen screw 4 Fitting the top Place the top by slotting it...

Страница 32: ...om or area as the product may affect its draw In Italy check the compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas fired products INSTALLATION Protection from heat and safety cle...

Страница 33: ...des of less than 1 5 terminate at roof level with a proper chimney pot the flue may not discharge directly on the wall or into an enclosed space even if the space in question is open to the sky be mad...

Страница 34: ...n general we suggest two ways to ensure a proper flow of combustion air Indirect air intake Install an air outlet at floor level with an effective sur face area net of the screen or other protections...

Страница 35: ...n 10 can compromise the operation of the stove The electrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an im...

Страница 36: ...m with an open expansion tank The presence of an accumulator tank is recommended but not mandatory Its advantage is that it releases the boiler stove from sudden requests from the system and can be in...

Страница 37: ...ressure reducer MI Delivery System P Pump circulator RA Radiators RI Return System S Drain SB Water heater ST Temperature Probe TC Boiler stove V Ball valve VA Automatic air vent valve VEC Closed expa...

Страница 38: ...38 ENGLISH led PUMP PUMP SPECIFICATIONS...

Страница 39: ...ed I II III Recommended for systems with fixed system resistance requiring a constant volume flow The pump reduces the delivery head to half in the case of decreasing volume flow in the pipe network E...

Страница 40: ...cel press and hold the operating button for 3 seconds SETTING THE CONTROL MODE Select control mode The LED selection of control modes and corresponding pump curves takes place in clockwise succession...

Страница 41: ...iable differential pressure p v III 4 Variable differential pressure p v II 5 Variable differential pressure p v I 6 Constant differential pressure p c III 7 Constant differential pressure p c II 8 Co...

Страница 42: ...ton for 8 seconds until the LEDs for the selected setting briefly flash then release LEDs flash constantly at 1 second intervals The key lock is activated pump settings can no longer be changed The ke...

Страница 43: ...rate pressure and ambient conditions Dry run Air in the pump Overload Sluggish motor pump is operated outside of its specifications e g high module temperature The speed is lower than during normal op...

Страница 44: ...ss on the cover which has a click opening use the glove if the stove is hot When the stove is hot DO NOT REST the bag of pellets on the upper grille Use the provided gloves when loading the stove whil...

Страница 45: ...informs the memory of the electronic board that has been inserted into the 15Kg tank a constant pressure of 5 deletes Kg residues or those previously entered ventilation button sets the operation of...

Страница 46: ...omatically shortened if the control board detects that certain tests have been carried out positively The flame appears after about 5 minutes Manual ignition in case of start up failure At a temperatu...

Страница 47: ...Sun Once you have chosen the day by scrolling through them with the and keys confirm by pressing MENU and proceed with the settings of the programs in the same way as for the Program daily selecting w...

Страница 48: ...he remote control you can set the display to the desired environmental temperature At environmental temperatures below the set temperature the stove modulates power normally to reach the set output Wi...

Страница 49: ...ultaneously for a few seconds to block unblock the keypad Indicates that ignition shutdown is being via the EASY TIMER program Indicates the room temperature detected by the remote control it indicate...

Страница 50: ...irm the setting by pressing the A button for a few seconds the icon will go off and the remaining time will appear on the synoptic panel after which the Easy timer setting will intervene e Repeat poin...

Страница 51: ...is invited to perform careful maintenance described above and explained by the DEALER during commissioning to the extent of his abilities To eliminate the message from the display press the ventilatio...

Страница 52: ...door P The grate consists of two parts A1 and A2 It is snapped into position in its housing 2 Empty the ash tray B and the grate into a non flammable container the ashes may still contain embers and...

Страница 53: ...original spare parts may damage the appliance and relieves Edilkamin of all liability for damage resulting there from Do not make unauthorised modifications DISPOSAL At the end of its service life dis...

Страница 54: ...ION BloccoAFNo Start displays when ignition times out unsuccessfully There are two possibilities NO flame Check that the grate is seated properly and is clean Check that there are pellets in the tank...

Страница 55: ...e technician MESSAGES WHICH DO NOT SHUT THE STOVE DOWN BUT ARE SIMPLY WARNINGS MESSAGE PROBLEM SOLUTION Check Battery The stove does not shut down but the term remains on the display The back up batte...

Страница 56: ...the safety thermostat has intervened A If the temperature is too high it switches OFF the product by cutting off the power supply to the gear motor If the thermostat is activated it must be reset pre...

Страница 57: ......

Страница 58: ......

Страница 59: ......

Страница 60: ...cod 941386 GB 10 18 H 941386 GB w w w e d i l k a m i n c o m...

Отзывы: