The ventilation is adjusted in sequence for the various fans (if present). If the product is not ducted, only one fan will be
present (F1).
The fan speed can be increased or decreased in the following sequence:
AUTO – 1 – 2 – 3 – 4 – 5 for the front fan (1)
OFF – AUTO – 1 – 2 – 3 – 4 – 5 for the ducted fans (2 and 3)
- FAN ADJUSTMENT
The setting can be made with the stove turned OFF or ON.
If the backlight is switched off, it can be activated by pressing any button.
Pressing the
or
button will make SET flash and, instead of the room set-point, the number of the fan being
modified will appear (F1). Simultaneously, the fan speed can be increased or decreased in the following sequence:
AUTO -1 -2 - 3 - 4 - 5 for the front fan (1)
OFF - AUTO - 1 - 2 - 3 - 4 - 5 for the ducted fans (2 and 3)
with this
button
with this
button