55
IT
ALIANO
If problems occur, the product shuts itself off automatically.
The display will show the reason (see below).
TROUBLESHOOTING
MESSAGE
PROBLEM
SOLUTION
A01 burning pot
dirty
displays when the combustion
air intake is below the set level
• Check that the combustion chamber door is closed
• Check the regular maintenance of the stove
• Check that smoke discharge and combustion air
ducts are clean.
A02
displays when the logic board
is not detecting the right smoke
fan speed
• Contact the technician
A03
displays when the thermocouple
detects a smoke temperature
lower than the set value and
interprets this as the absence of
flame
• Check that there are pellets in the tank
• Check that the water temperature has not increased
due to the closure of a valve (call a technician)
• Contact the technician
A04
displays when ignition times out
unsuccessfully
There are two possibilities:
NO flame:
• Check that the burning pot is seated properly and clean
• Check that there are pellets in the tank and burning pot
• Try switching it on with a solid ecological igniter (contact
the technician beforehand and follow the instructions of
the igniter supplier very carefully).
The operation must be regarded purely as a trial under the
technician’s guidance
A05
Shutdown due to air flow rate
sensor breakage
• Contact the technician
A06
displays when the logic board
determines that the smoke
temperature probe is broken or
disconnected
• Contact the technician
M
®Ä
T
«
14.9
°
C
15:36
off
A01
BURNING POT DIRTY