EdilKamin 809530 Скачать руководство пользователя страница 30

30

ENGLISH

FIRST IGNITION (COMMISSIONING) PHASES

•  Make sure you have read and understood this 

manual

•  Remove all flammable materials from the appliance 

(manuals, labels, etc.). In particular remove any 
labels from the glass. 

INSTALLATION

On first ignition, there may be a slight smell 
of paint, which will disappear in a short 
time.

FUEL 

Use  UNI  EN  ISO  17225-2  category  A1  wood  pellets 

Use UNI EN ISO 17225-2 category A1 wood pellets 
or  similar  regulatory  products  with  the  following 

or similar regulatory products with the following 
characteristics.

characteristics.
diameter 6 mm

diameter 6 mm
length 3-4 cm

length 3-4 cm
humidity <10 %

humidity <10 %

For reasons of safety and environmental compatibility, 
DO NOT burn plastic, painted wood, coal, bark or 
other such materials in the stove. 
Do not use the product as an incinerator.

Caution
Using fuels other than those specified can 
damage the appliance

OPENING THE DOOR WITH THE LEVER

To open the door (for regular cleaning and first time) 

To open the door (for regular cleaning and first time) 
use the appropriate lever (removable handle)

use the appropriate lever (removable handle)
See figure 15.

See figure 15.

LOADING THE PELLETS INTO THE PELLET 
TANK

Depending on the version, you can load the pellets:

Depending on the version, you can load the pellets:
• 

•  via the trapdoor

via the trapdoor

• 

•  via the front drawer

via the front drawer

Load the pellets by removing the frontal drawer. 
Use the glove when the appliance is hot. The pellets 
can be loaded even when the fire is burning.

protective lever 

protective lever 

Содержание 809530

Страница 1: ...PELLKAMIN2 12 PELLET FIREPLACE UK Installation use and maintenance 809530 809550 809580 809560...

Страница 2: ...version Fitting the components according to the version Pellet loading trapdoor 17 Pellet loading trapdoor 17 Ducted ventilation 18 Ducted ventilation 18 Frontal ventilation kit 21 Frontal ventilation...

Страница 3: ...ted up for the first time commissioned by a qualified Edilkamin technician In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure bes...

Страница 4: ...THAN WOOD PELLETS IN THE HEARTH The product may be soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT...

Страница 5: ...3 2 5 60 5 2 5 5 PELLKAMIN2 12 with frontal ventilation and a pellet loading drawer 8 cm smoke outlet 79 93 87 5 12 93 60 5 2 5 60 5 2 5 5 PELLKAMIN2 12 with ducted ventilation and a pellet loading dr...

Страница 6: ...E hole for the vents Split Bent Origami Sharp F hole for ventilation air recovery a 10x10 cm hole in the side of the cladding 18 5 19 4 4 18 5 20 70 150 87 5 88 A F C C MEASUREMENTS cm OF HOLES ON PLA...

Страница 7: ...ng cod 809530 218 kg cod 809560 271 kg cod 809550 249 kg cod 809580 273 kg kg Energy efficiency classes 2015 1186 Regulation A TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the req...

Страница 8: ...in a regulatory fashion CONTENTS OF PACKAGE The packaging varies according to the Pellkamin version The packages are described in the Packaging section The air outlet vents are not included in the ver...

Страница 9: ...facilitate handling the PELLKAMIN2 12 is fitted with handles B Do not use the air intake or fumes outlet to handle the appliance This may lead to slight misalignments TO UNPACK THE PRODUCT undo screws...

Страница 10: ...rround Pellkamin is available in four versions 1 with ducted ventilation and a pellet loading trapdoor see the fitting sections on Ducted Ventilation and Load ing Trapdoor 2 with frontal ventilation a...

Страница 11: ...ontal ventilation kit Version 3 with frontal ventilation and pellet loading drawer One package 1 with the Pellkamin frame the two compensation vents the inlet surround One package 2 with the drawer an...

Страница 12: ...Ducting for ventilation air Ducting for ventilation air always channel the ventilation warm air the 6 cm diam eter pipe to the outside INSTALLATION IN AN EXISTING FIREBOX INSTALLATION IN AN EXISTING...

Страница 13: ...ng wind its safety equipment may switch the fireplace off Contact the authorised Edilkamin Technical Assistance Centre INSTALLATION FLUE SYSTEM FLUE SYSTEM Fumes duct flue and chimney pot Fumes duct f...

Страница 14: ...tions THE FLUE THE FLUE Further to the general prescriptions for the fumes duct and flue the flue must serve solely to exhaust fumes must be correctly sized to satisfy the requirements of fumes exhaus...

Страница 15: ...tion TERMINAL BOARDS The right side of the appliance seen from the front has a bracket with two terminal boards the upper terminal board low voltage has a pre wired cable for the reset button while th...

Страница 16: ...ay that the plug is accessible once the installation is complete Secure the bottom of the base to the floor with 8 mm steel anchor bolts to prevent it from tipping over Position the top of the base 2...

Страница 17: ...the plasterboard Secure the loading inlet A Screw A with B Open the loading inlet to reach the screws Insulate the loading tube and make sure that it does not touch the fumes duct The loading tube mu...

Страница 18: ...luminium pipe extendible to 1 5 m for connection from the fire box to the fan kit 5 n 2 6 cm aluminium pipe extendible to 3 m for connection from the fan kit to the vent the flanges are incorporated i...

Страница 19: ...a Please see the picture of an exemple with pellet loa ding hatch ding hatch E E and vent Label and vent Label F F The instructions for installing the vents are included with the vents themselves NOTE...

Страница 20: ...door 2 remove the screws 3 remove the cover panel 4 rotate the fan taking care with the cables to be extracted 5 reinsert the fan 6 repeat the operations to reattach the door and ro tate the box Posi...

Страница 21: ...ically connect the fan to the circuit board as shown on the high voltage terminal board to the side poles electrically connect the fan to the circuit board as shown on the high voltage terminal board...

Страница 22: ...22 ENGLISH FRONTAL VENTILATION KIT 2 2 4 3 repeat on the other side 4 screws VERSION WITH FRONTAL VENTILATION AND TRAPDOOR LOADING 2...

Страница 23: ...pe of installation also ducting or not during the first ignition The ventilation will not function properly if the technician does not adjust the parameters The ventilation will not function properly...

Страница 24: ...screw the ceramic front panel to the frame with its support 3 There are 5 screws in all two on each side and one in the centre one in the centre 3 3 replace the metal cover with the drawer Kit 2 and...

Страница 25: ...LOADING DRAWER 2 3 Figure 12 Drawer fitted Connecting the pipes for ducting hot air Connecting the pipes for ducting hot air 2 3 repeat on the other side 4 screws VERSION WITH DUCTED VENTILATION AND D...

Страница 26: ...the high voltage terminal board to the side poles electrically connect the fan to the circuit board as shown on the high voltage terminal board to the side poles 7 8 9 Line Earth Neutral respectively...

Страница 27: ...t operation it is essential that the technician adjusts the parameters according to To ensure correct operation it is essential that the technician adjusts the parameters according to the type of inst...

Страница 28: ...e ventilation kit an additional opening of at least 10x10 cm in size is available in one side of the cover for ventilation air recovery any wooden beams are insulated and not resting against the metal...

Страница 29: ...the surround on to its supports secure it with the four grub screws included for the side versions fasten it to the bracket with a nut D For versions 2 with frontal ventilation and pellet loading tra...

Страница 30: ...onmental compatibility DO NOT burn plastic painted wood coal bark or other such materials in the stove Do not use the product as an incinerator Caution Using fuels other than those specified can damag...

Страница 31: ...s ON Flame ignites and grows stable This is the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable du...

Страница 32: ...the type of batteries and the intensity of use Edilkamin and the reseller will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top l...

Страница 33: ...lay shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames 5 the fan level represented by the fillin...

Страница 34: ...3 and displayed as positions 2 and 3 see below The two fans can be adjusted separately First adjust fan 2 and then fan 3 as described below Ventilation setting Press OK once The fan setting displays...

Страница 35: ...temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use...

Страница 36: ...ress the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined...

Страница 37: ...buttons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button...

Страница 38: ...ckly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose be...

Страница 39: ...n during commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu...

Страница 40: ...Confirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll u...

Страница 41: ...N B Any unauthorised modification is forbidden Use spare parts recommended by the manufacturer The use of counterfeit parts results in the guarantee becoming null and void MAINTENANCE Never vacuum ho...

Страница 42: ...tray 3 and grate into a non flammable container the ashes may still contain embers and or hot parts Vacuum out the interior of the hearth the bed and the compartment around the grate into which the as...

Страница 43: ...nd inspect the system there is an increased risk of the chimney pot catching fire SUMMER SHUTDOWN During the period of disuse keep the fireplaces doors hatches and lids closed We recommend emptying ou...

Страница 44: ...sufficient quantity of combustion air Check that the firebox door is closed Check that the grate and fume discharge are clean Check that the external air inlet is free i e the grilles are not obstruct...

Страница 45: ...cian MESSAGE PROBLEM SOLUTION H07 Shutdown due to exceeding maximum fumes temperature Check the type of pellet contact the technician if in doubt Contact the technician H08 Shutdown due to overheating...

Страница 46: ......

Страница 47: ......

Страница 48: ...cod 942077 GB 04 19 A 942077 GB w w w e d i l k a m i n c o m...

Отзывы: