EdilKamin 809530 Скачать руководство пользователя страница 3

3

ENGLISH

Dear Sir/Madam
Congratulations on choosing our product. Before you 
use it, please read this manual carefully, to get the best 
from your new appliance in total safety.

This manual is an integral part of the product. Please 
keep it for the entire life of the product. 
If you lose it, you can request a copy or download it 
from www.edilkamin.com

After unpacking the product, check the condition and 
completeness of the contents. 
In the event of error, immediately contact the retailer 
where the purchase was made, providing him with a 
copy of the warranty booklet and the sales receipt.

The appliance must be installed and operated in 
compliance with local and national law and European 
regulations. For the installation, and for anything not 
specifically indicated in the manual, observe local 
regulations. 

The diagrams in this manual are illustrative; they do 
not always refer specifically to your product and are 
not binding in any way.

The product is uniquely identified by a number, the 
“counterfoil”, which is indicated on the warranty 
certificate inside the product.

Please keep:
•  the warranty certificate accompanying the product
•  the purchase receipt given to you by the retailer
•  the declaration of conformity given to you by the 

installer. 

The warranty conditions are given in the warranty 
certificate accompanying the product.

We recommend that the appliance be started up for 
the first time (commissioned) by a qualified Edilkamin 
technician. 

In Italy, commissioning by an authorised technician 
is required by UNI 10683, and is recommended in all 
countries to ensure best results from the product.

This consists in:
•  checking the installation documents (declaration of 

conformity) and the quality of the installation itself;

•  calibrating the product to suit its actual application
• explanation to the end user and issue of 

complementary documentation (commissioning 
certificate)

Having the appliance commissioned properly ensures 
that it will operate to best effect and in complete safety.
Proper commissioning is required for activation of the 
Edilkamin warranty. The warranty is only valid in the 
country of sale of the product.
If the appliance is not commissioned by an authorised 
technician, Edilkamin will not provide warranty service. 
See the warranty booklet for details. The above terms 
do not affect the reseller’s legal responsibility for the 
legal warranty.

The warranty covers only demonstrable manufacturing 
defects and not, for instance, problems resulting from 
improper installation or calibration.

MEANING OF SYMBOLS

In some parts of the manual the following symbols 
are used:

INFORMATION:

 

failure to comply with these 
requirements will compromise 
product use.

PLEASE NOTE:

 

carefully read and understand the 
message in question, since failure 
to follow the instructions in it could 
cause serious damage to the 
product and put  the safety of those 
using it at risk. 

OPERATING SEQUENCE:

 

follow the instructions for the 
operations described

Содержание 809530

Страница 1: ...PELLKAMIN2 12 PELLET FIREPLACE UK Installation use and maintenance 809530 809550 809580 809560...

Страница 2: ...version Fitting the components according to the version Pellet loading trapdoor 17 Pellet loading trapdoor 17 Ducted ventilation 18 Ducted ventilation 18 Frontal ventilation kit 21 Frontal ventilation...

Страница 3: ...ted up for the first time commissioned by a qualified Edilkamin technician In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure bes...

Страница 4: ...THAN WOOD PELLETS IN THE HEARTH The product may be soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT...

Страница 5: ...3 2 5 60 5 2 5 5 PELLKAMIN2 12 with frontal ventilation and a pellet loading drawer 8 cm smoke outlet 79 93 87 5 12 93 60 5 2 5 60 5 2 5 5 PELLKAMIN2 12 with ducted ventilation and a pellet loading dr...

Страница 6: ...E hole for the vents Split Bent Origami Sharp F hole for ventilation air recovery a 10x10 cm hole in the side of the cladding 18 5 19 4 4 18 5 20 70 150 87 5 88 A F C C MEASUREMENTS cm OF HOLES ON PLA...

Страница 7: ...ng cod 809530 218 kg cod 809560 271 kg cod 809550 249 kg cod 809580 273 kg kg Energy efficiency classes 2015 1186 Regulation A TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the req...

Страница 8: ...in a regulatory fashion CONTENTS OF PACKAGE The packaging varies according to the Pellkamin version The packages are described in the Packaging section The air outlet vents are not included in the ver...

Страница 9: ...facilitate handling the PELLKAMIN2 12 is fitted with handles B Do not use the air intake or fumes outlet to handle the appliance This may lead to slight misalignments TO UNPACK THE PRODUCT undo screws...

Страница 10: ...rround Pellkamin is available in four versions 1 with ducted ventilation and a pellet loading trapdoor see the fitting sections on Ducted Ventilation and Load ing Trapdoor 2 with frontal ventilation a...

Страница 11: ...ontal ventilation kit Version 3 with frontal ventilation and pellet loading drawer One package 1 with the Pellkamin frame the two compensation vents the inlet surround One package 2 with the drawer an...

Страница 12: ...Ducting for ventilation air Ducting for ventilation air always channel the ventilation warm air the 6 cm diam eter pipe to the outside INSTALLATION IN AN EXISTING FIREBOX INSTALLATION IN AN EXISTING...

Страница 13: ...ng wind its safety equipment may switch the fireplace off Contact the authorised Edilkamin Technical Assistance Centre INSTALLATION FLUE SYSTEM FLUE SYSTEM Fumes duct flue and chimney pot Fumes duct f...

Страница 14: ...tions THE FLUE THE FLUE Further to the general prescriptions for the fumes duct and flue the flue must serve solely to exhaust fumes must be correctly sized to satisfy the requirements of fumes exhaus...

Страница 15: ...tion TERMINAL BOARDS The right side of the appliance seen from the front has a bracket with two terminal boards the upper terminal board low voltage has a pre wired cable for the reset button while th...

Страница 16: ...ay that the plug is accessible once the installation is complete Secure the bottom of the base to the floor with 8 mm steel anchor bolts to prevent it from tipping over Position the top of the base 2...

Страница 17: ...the plasterboard Secure the loading inlet A Screw A with B Open the loading inlet to reach the screws Insulate the loading tube and make sure that it does not touch the fumes duct The loading tube mu...

Страница 18: ...luminium pipe extendible to 1 5 m for connection from the fire box to the fan kit 5 n 2 6 cm aluminium pipe extendible to 3 m for connection from the fan kit to the vent the flanges are incorporated i...

Страница 19: ...a Please see the picture of an exemple with pellet loa ding hatch ding hatch E E and vent Label and vent Label F F The instructions for installing the vents are included with the vents themselves NOTE...

Страница 20: ...door 2 remove the screws 3 remove the cover panel 4 rotate the fan taking care with the cables to be extracted 5 reinsert the fan 6 repeat the operations to reattach the door and ro tate the box Posi...

Страница 21: ...ically connect the fan to the circuit board as shown on the high voltage terminal board to the side poles electrically connect the fan to the circuit board as shown on the high voltage terminal board...

Страница 22: ...22 ENGLISH FRONTAL VENTILATION KIT 2 2 4 3 repeat on the other side 4 screws VERSION WITH FRONTAL VENTILATION AND TRAPDOOR LOADING 2...

Страница 23: ...pe of installation also ducting or not during the first ignition The ventilation will not function properly if the technician does not adjust the parameters The ventilation will not function properly...

Страница 24: ...screw the ceramic front panel to the frame with its support 3 There are 5 screws in all two on each side and one in the centre one in the centre 3 3 replace the metal cover with the drawer Kit 2 and...

Страница 25: ...LOADING DRAWER 2 3 Figure 12 Drawer fitted Connecting the pipes for ducting hot air Connecting the pipes for ducting hot air 2 3 repeat on the other side 4 screws VERSION WITH DUCTED VENTILATION AND D...

Страница 26: ...the high voltage terminal board to the side poles electrically connect the fan to the circuit board as shown on the high voltage terminal board to the side poles 7 8 9 Line Earth Neutral respectively...

Страница 27: ...t operation it is essential that the technician adjusts the parameters according to To ensure correct operation it is essential that the technician adjusts the parameters according to the type of inst...

Страница 28: ...e ventilation kit an additional opening of at least 10x10 cm in size is available in one side of the cover for ventilation air recovery any wooden beams are insulated and not resting against the metal...

Страница 29: ...the surround on to its supports secure it with the four grub screws included for the side versions fasten it to the bracket with a nut D For versions 2 with frontal ventilation and pellet loading tra...

Страница 30: ...onmental compatibility DO NOT burn plastic painted wood coal bark or other such materials in the stove Do not use the product as an incinerator Caution Using fuels other than those specified can damag...

Страница 31: ...s ON Flame ignites and grows stable This is the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable du...

Страница 32: ...the type of batteries and the intensity of use Edilkamin and the reseller will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top l...

Страница 33: ...lay shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames 5 the fan level represented by the fillin...

Страница 34: ...3 and displayed as positions 2 and 3 see below The two fans can be adjusted separately First adjust fan 2 and then fan 3 as described below Ventilation setting Press OK once The fan setting displays...

Страница 35: ...temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use...

Страница 36: ...ress the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined...

Страница 37: ...buttons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button...

Страница 38: ...ckly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose be...

Страница 39: ...n during commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu...

Страница 40: ...Confirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll u...

Страница 41: ...N B Any unauthorised modification is forbidden Use spare parts recommended by the manufacturer The use of counterfeit parts results in the guarantee becoming null and void MAINTENANCE Never vacuum ho...

Страница 42: ...tray 3 and grate into a non flammable container the ashes may still contain embers and or hot parts Vacuum out the interior of the hearth the bed and the compartment around the grate into which the as...

Страница 43: ...nd inspect the system there is an increased risk of the chimney pot catching fire SUMMER SHUTDOWN During the period of disuse keep the fireplaces doors hatches and lids closed We recommend emptying ou...

Страница 44: ...sufficient quantity of combustion air Check that the firebox door is closed Check that the grate and fume discharge are clean Check that the external air inlet is free i e the grilles are not obstruct...

Страница 45: ...cian MESSAGE PROBLEM SOLUTION H07 Shutdown due to exceeding maximum fumes temperature Check the type of pellet contact the technician if in doubt Contact the technician H08 Shutdown due to overheating...