8.2 TIMING FUNCTIONS
Conflict
(no fault) ..................................... less than 200 milliseconds
(fault) ...................................... greater than 500 milliseconds
(typical) ...................................................... 350 milliseconds
VDC Failed
(no fault) ..................................... less than 200 milliseconds
(fault) ...................................... greater than 500 milliseconds
(typical) ...................................................... 400 milliseconds
Watchdog 1.0 second
(no fault) ..................................... less than 900 milliseconds
(fault) .................................... greater than 1100 milliseconds
(typical) ..................................................... 1000 milliseconds
Watchdog 1.5 second
(no fault) .................................... less than 1400 milliseconds
(fault) .................................... greater than 1600 milliseconds
(typical) ..................................................... 1500 milliseconds
Red Fail
(no fault) ..................................... less than 700 milliseconds
(fault) .................................... greater than 1000 milliseconds
(typical) ....................................................... 850 milliseconds
Red Fail (2010)
(no fault) .................................... less than 1200 milliseconds
(fault) .................................... greater than 1500 milliseconds
(typical) ..................................................... 1350 milliseconds
Dual Indication
(no fault) ..................................... less than 200 milliseconds
(fault) ...................................... greater than 500 milliseconds
(typical) ...................................................... 400 milliseconds
Dual Indication Long
(no fault) ..................................... less than 700 milliseconds
(fault) .................................... greater than 1000 milliseconds
(typical) ...................................................... 850 milliseconds
Clearance
(no fault) ........................................ greater than 2.8 seconds
(fault) .................................................. less than 2.6 seconds
AC Line 2010 Brown-out
(drop-out) ............................................ 450 _
+50 milliseconds
(restore) ............................................... 450 _
+50 milliseconds
Minimum flash after restore ...................................................................... 6.0 +
_0.5 seconds
Maximum flash after restore .................................................................... 10.0 +
_0.5 seconds
Watchdog (2010)
(disable) ...............................................400 _
+50 milliseconds
(enable) ................................................400 _
+50 milliseconds
Watchdog (210E)
(disable) ................................................ 80 _
+17 milliseconds
(enable) ................................................. 80 _
+17 milliseconds
FYA Flash Rate
no fault .................................................. less than 1400 msec
fault .................................................. greater than 1600 msec
8.3 MECHANICAL
Height ................................................................................................................. 9.3 inches
Width ................................................................................................................. 1.38 inches
Depth .............................................................................................................. 10.17 inches
8.4 ENVIRONMENTAL
Storage Temperature Range .......................................................................... -55 to +90
o
C
Operating Temperature Range ....................................................................... -37 to +74
o
C
Humidity Range ....................................................................................... 0 to 95% Relative