6-8
2000-CSS COMBINED SONAR
0017423_REV_C
The SockBlast application is used to test network throughput between the towfish and the topside
computer. This application is normally kept in C:\EdgeTech\Utilities folder on the topside unit, and
D:\EdgeTech\Utilities folder on the towfish.
Figure 6-1: SockBlast Window
Two copies must be run one on each computer. One serves as the client (topside) and the other as the
server (towfish). Since the client connects to the server, the Create Client (topside) address must be the
TCP/IP address of the server (towfish) machine, which is 192.9.0.99. The towfish Create Server address
should be 0.0.0.0.
After pressing the Create buttons to start the server and clients on their respective machines, the two
applications hook up, then the Client count on the towfish should increment from 0 to 1 and the Server
count on the topside should increment to 1 as well. This indicates that there is one connection between
the two applications
Check the Server Send Data box on the towfish. A performance in MB/second will be displayed. This
should be more than 0.35Mbyte/s.
6.3.7
Towfish
First verify that the command and data links between the towfish and topside are working per above.
NOTE:
It is recommended that all attempts be made to see if a problem
is external to the towfish before opening it.
WARNING!
High voltage (400 VDC) is always present in the electronics
assembly when powered.
Содержание 2000-CSS
Страница 26: ......
Страница 34: ......
Страница 59: ...Figure 4 5 STARMUX III Wiring Diagram...
Страница 64: ...Figure 4 7 Towfish Block Diagram...
Страница 66: ...Figure 4 8 Armored Cable PMI Grip Unterminated Topside...
Страница 67: ...Figure 4 9 Test Cable...
Страница 68: ......
Страница 100: ......