6-1
6.0:
TROUBLESHOOTING
Should some operational or performance problems occur with the 2000 Series Combined Side Scan Sonar
and Sub-Bottom Profiling System, it may be possible to correct them using the troubleshooting guides in
the following pages. For the Topside Computer and the STARMUX III Digital Telemetry Link, tabular
troubleshooting guides are provided in
, respectively. These troubleshooting guides
identify some symptoms that could occur and presents one or more possible causes and the
recommended corrective action for each. Perform the corrective action for any given symptom in the
order of possible causes, which generally corresponds to the degree of troubleshooting difficulty, from
the simple to the more complex.
For the towfish, detailed information is provided in the
Before proceeding with any corrective action, verify that the 2000 Topside computer is plugged into an
appropriate AC or DC power source and that it is switched on.
NOTE:
Be sure to also verify that all the cables on the 2000 Topside
computer and the towfish are mated and are not loose or damaged. Most
causes of operational or performance problems are a result of poor
connections.
6.1
2000 Topside computer Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
The green SYSTEM POWER
indicator on the 2000 Topside
computer does not illuminate
when the processor is turned on.
The POWER switch is not turned
on.
Verify that the POWER switch
on the back panel is on.
No AC power.
Verify that the 2000 Topside
computer is connected to AC
power. Check the AC power
source.
The indicator is not operating.
Open the 2000 Topside
computer and check the
indicator and wiring.
Содержание 2000-CSS
Страница 26: ......
Страница 34: ......
Страница 59: ...Figure 4 5 STARMUX III Wiring Diagram...
Страница 64: ...Figure 4 7 Towfish Block Diagram...
Страница 66: ...Figure 4 8 Armored Cable PMI Grip Unterminated Topside...
Страница 67: ...Figure 4 9 Test Cable...
Страница 68: ......
Страница 100: ......