EdgeStar TWR187ESS Скачать руководство пользователя страница 4

General Safety 

  Always unplug an appliance from the power supply before attempting any service. Disconnect the 

power cord by grasping the plug, not the cord. 

  Do not allow children or pets to play on or in the appliance.  

  This machine is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the machine by a person responsible for their safety. 

  Do not install or store this appliance where it will be exposed to the weather. 

  Disconnect from the power socket before cleaning or maintenance.  

  If the plug (power cord) is damaged, it must be replaced by the manufacturer or an authorized service 

representative. 

  This machine shall be repaired only by an authorized service representative. Only genuine 

replacement parts should be used. 

  If connected to a circuit protected by fuses, use time-delay fuses with this appliance. 

  Do not lean items against the glass door. 

  Please do not close the door with excessive force. If it is found difficult to close the door, please check 

for obstruction. 

  When you plan to dispose of this unit in the future, please comply with the local waste disposal 

regulations. Remove the door so that children and pets will not be trapped in the unit. 

 

 

Содержание TWR187ESS

Страница 1: ...EdgeStar 8606 Wall St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Document Type Service Manual Version V1 0 02052018...

Страница 2: ...ended for use by certified technicians The manufacturer or seller is not responsible for the interpretation or misuse of the information provided nor does it assume any liability in connection with it...

Страница 3: ...appliance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...antly in a moist place This moisture will drain into the condensate tray at the back of the unit and may require emptying if excessive moisture is collected in a short period of time Finding a good sp...

Страница 6: ...ductor materials The complete system includes a semi conductor module P N shape semi conductors clamped with two ceramic chips an internal and external heat exchanger To obtain higher energy efficienc...

Страница 7: ...Exploded View Diagram...

Страница 8: ...Parts List...

Страница 9: ...Circuit Board Diagram...

Страница 10: ...0W Rated Current 1 0A Net Weight 35 3 lbs Model TWR247ESS Voltage Frequency 115V 60Hz Power 100W Rated Current 1 4A Net Weight 39 lbs Note Specifications are subject to change Check the rating label o...

Страница 11: ...Power Supply Board 1 Power Cord 2 Thermoelectric Module 3 Heating Fan 4 Cooling Fan 5 Temperature Controller 6 Temperature Sensor...

Страница 12: ...er disconnect the wire connectors on the Power Supply Board and replace with new board 2 Reconnect the connectors on the Power Supply Board 3 Reconnect the connectors on the Power Junction Board 4 Rec...

Страница 13: ...m the rear of the door 3 Remove the screws 2 from the temperature controller box then disassemble the door frame 4 Pull out the temperature controller disconnect the wire connector and replace with ne...

Страница 14: ...Thermoelectric Module and Heat Fan Replacing Thermoelectric Module and Heat Fan 1 Disconnect the wire connector from Thermoelectric Module to the PCB 2 Removing the screws 2 on the module...

Страница 15: ...4 Remove the screws 4 from the two sides of heat sink 5 Replace the heat fan 6 Reattach the screws 4 7 Put bracket into the proper position and reattach the screws 2 on the module 8 Reconnect the wir...

Страница 16: ...oling fan cover 2 Removing the screws 4 on the cooling fan cover 3 Disconnect the wire connector after opening the cooling fan cover 4 Remove the screws 4 from the cooling fan 5 Replace the old coolin...

Страница 17: ...7 Fix the sensor into the proper position 6 Reattach the caps 4 and screws 4...

Страница 18: ...bassembly 1 Remove the screws to remove the heat fan subassembly 2 Remove two 2 screws 3 Disassemble heat sink 4 Remove old node and apply thermal grease evenly on new node 5 Replace the thermoelectri...

Страница 19: ...Error Codes Model No Error Code Meaning of Error code Lo L Er E TWR187ESS TWR247ESS Lo Er The temperature sensor has open circuit The temperature sensor has short circuit...

Страница 20: ...Diagnostics Wine cooler does not cool or will not run NO YES NO YES NO YES NO...