Electrical Safety 

  Do not exceed the power outlet ratings.  

  It is recommended that the unit be connected to its own circuit.  

  A standard electrical supply (120V, 60Hz), that is properly grounded in accordance with the National 

Electrical Code and all state and local codes and ordinances is required.   

  Do not use outlets that can be turned off by a switch or pull chain. 

  Always turn the unit off and unplug it from the outlet when cleaning. 

  Unplug the unit if it is not going to be used for an extended period of time.  

  Do not operate the unit with a power plug missing the ground plug, a damaged cord, or a loose socket. 

  Be sure the appliance is properly grounded. 

  Do not bypass, cut, or remove the grounding plug.  

  If the power cord is damaged, it must be replaced by the manufacturer or a qualified technician.  

  Do not use extension cords or power strips with this unit. You may need to contact an electrician if it is 

necessary to use a longer cord or if you do not have a properly grounded outlet. Do not modify the 
power cord’s length or share the outlet with other appliances.  

 

Do not start or stop the unit by switching the electrical circuit’s power on and off. 

  Immediately unplug the unit if it makes strange sounds, emits an odor or smoke and contact customer 

service. 

  Do not remove any part of the casing unless instructed by an authorized technician. 

  Before the appliance is removed from service or discarded, remove the door and cut off the power 

cord.

 

 

Содержание TWR187ESS

Страница 1: ...EdgeStar 8606 Wall St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Document Type Service Manual Version V1 0 02052018...

Страница 2: ...ended for use by certified technicians The manufacturer or seller is not responsible for the interpretation or misuse of the information provided nor does it assume any liability in connection with it...

Страница 3: ...appliance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...antly in a moist place This moisture will drain into the condensate tray at the back of the unit and may require emptying if excessive moisture is collected in a short period of time Finding a good sp...

Страница 6: ...ductor materials The complete system includes a semi conductor module P N shape semi conductors clamped with two ceramic chips an internal and external heat exchanger To obtain higher energy efficienc...

Страница 7: ...Exploded View Diagram...

Страница 8: ...Parts List...

Страница 9: ...Circuit Board Diagram...

Страница 10: ...0W Rated Current 1 0A Net Weight 35 3 lbs Model TWR247ESS Voltage Frequency 115V 60Hz Power 100W Rated Current 1 4A Net Weight 39 lbs Note Specifications are subject to change Check the rating label o...

Страница 11: ...Power Supply Board 1 Power Cord 2 Thermoelectric Module 3 Heating Fan 4 Cooling Fan 5 Temperature Controller 6 Temperature Sensor...

Страница 12: ...er disconnect the wire connectors on the Power Supply Board and replace with new board 2 Reconnect the connectors on the Power Supply Board 3 Reconnect the connectors on the Power Junction Board 4 Rec...

Страница 13: ...m the rear of the door 3 Remove the screws 2 from the temperature controller box then disassemble the door frame 4 Pull out the temperature controller disconnect the wire connector and replace with ne...

Страница 14: ...Thermoelectric Module and Heat Fan Replacing Thermoelectric Module and Heat Fan 1 Disconnect the wire connector from Thermoelectric Module to the PCB 2 Removing the screws 2 on the module...

Страница 15: ...4 Remove the screws 4 from the two sides of heat sink 5 Replace the heat fan 6 Reattach the screws 4 7 Put bracket into the proper position and reattach the screws 2 on the module 8 Reconnect the wir...

Страница 16: ...oling fan cover 2 Removing the screws 4 on the cooling fan cover 3 Disconnect the wire connector after opening the cooling fan cover 4 Remove the screws 4 from the cooling fan 5 Replace the old coolin...

Страница 17: ...7 Fix the sensor into the proper position 6 Reattach the caps 4 and screws 4...

Страница 18: ...bassembly 1 Remove the screws to remove the heat fan subassembly 2 Remove two 2 screws 3 Disassemble heat sink 4 Remove old node and apply thermal grease evenly on new node 5 Replace the thermoelectri...

Страница 19: ...Error Codes Model No Error Code Meaning of Error code Lo L Er E TWR187ESS TWR247ESS Lo Er The temperature sensor has open circuit The temperature sensor has short circuit...

Страница 20: ...Diagnostics Wine cooler does not cool or will not run NO YES NO YES NO YES NO...