Installing and Removing the Shelves 

Installing the Shelves 

1.  Open the door completely. 
2.  Ensure that the plastic posts are installed on the left and right sides of the shelf track 

onto which you are attempting to install the shelf.  

3.  Lifting the rear of the shelf upwards above the shelf track, align the left and right sides 

of the shelf over the plastic posts mounted to the inner cabinet. 

4.  Gently set the shelf down on the shelf track.  

Removing the Shelves 

1.  Open the door completely. 
2.  Make sure the shelf is pushed back completely. 
3.  Lift either the left or right side of the shelf to create a 45° angle from its original 

position. Make sure not to lift either side of the shelf too hard as it may come in 
contact with the inner wall mount.   

4.  Pull the shelf outward until it is removed from the inner compartment. You may 

encounter some resistance from the shelf guard rail.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operation 

Installation Check List Before Operation 

1.  Have all packing materials and tape been removed from the interior and exterior of the 

medical refrigerator? 

2.  Have the installation instructions been followed, including connecting the machine to 

electricity? And has proper grounding been installed for the medical refrigerator? 

3.  Has the machine been leveled? 
4.  Is the medical refrigerator in a site where the ambient temperature is between 50° F 

and 95° F all year round? 

5.  Is there a clearance of at least 5

” at the rear, 3” at the top, and 3” at the sides for proper 

air circulation? 

 

 
Tip: To prevent damaging the door gasket, make sure to open the door fully before pulling the 
shelves out of their track. 

Содержание RP401MED

Страница 1: ...V1 1 04092020 Precision Cooled Refrigerator Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com RP401MED...

Страница 2: ...unit with a power plug missing the ground plug a damaged cord or a loose socket Be sure the beverage refrigerator is properly grounded Avoid installation in high humidity environments such as bathroom...

Страница 3: ...ces such as aerosol cans with flammable propellant in this appliance Do not place the unit near heat sources such as ovens grills or direct sunlight Only use in an upright position on a flat level sur...

Страница 4: ...CAL REFRIGERATOR 5 INSTALLING THE DOOR HANDLE 5 INSTALLING AND REMOVING THE SHELVES 6 Installing the Shelves 6 Removing the Shelves 6 OPERATION 6 INSTALLATION CHECK LIST BEFORE OPERATION 6 USING THE T...

Страница 5: ......

Страница 6: ...and efficiency Please save the original product packaging in case you need to safely transport your medical refrigerator For Your Records Please write down the model number and serial number below fo...

Страница 7: ...2 Parts Identification Front View Back View...

Страница 8: ...w the compressor s oils to settle Unpacking the Medical Refrigerator Free standing Installation A free standing installation will allow you to install the medical refrigerator in almost any place you...

Страница 9: ...n A standard electrical supply 115 V 60Hz properly grounded in accordance with the National Electrical Code and local codes and ordinances is required It is recommended that a separate circuit serving...

Страница 10: ...side 2 Adjust the height of the feet as follows Turn the leveling feet to the right to lower that side of the refrigerator Turn the leveling feet to the left to raise that side of the refrigerator Ins...

Страница 11: ...rd as it may come in contact with the inner wall mount 4 Pull the shelf outward until it is removed from the inner compartment You may encounter some resistance from the shelf guard rail Operation Ins...

Страница 12: ...ol panel to increase the temperature by 1 degree increments Press the C F button to switch the display between Fahrenheit and Celsius The Celsius or Fahrenheit light will be lit depending on which uni...

Страница 13: ...lay by 1 Press and hold the HI button to advance by 5 3 To set the LOW temperature alarm limit press the LO button to advance the display by 1 Press and hold the LO button to advance by 5 Thermostat A...

Страница 14: ...ing sound due to the refrigerant flowing in your medical refrigerator You may hear air being forced over the condenser by the condenser fan Door Ajar Alarm This refrigerator includes a door ajar alarm...

Страница 15: ...old mildew and unpleasant smells Cleaning and Maintenance Periodic cleaning and proper maintenance will ensure efficiency top performance and long life Exterior Cleaning The doors and cabinet may be c...

Страница 16: ...e Ensure that the refrigerator is plugged in and the power outlet has power The refrigerator is not plugged in Plug the unit in to a power outlet that has sufficient amperage A house fuse has blown or...

Страница 17: ...ds up you can try running the refrigerator on a warmer temperature setting minimizing the number of times you open the door or unplugging the unit to allow the frost to melt The ambient temperature is...

Страница 18: ...nge 32 F 50 F Dimensions Height x Width x Depth 33 3 8 x 19 7 16 x 23 7 16 Net Weight 73 lbs Depth indicated does not include the product s handle Depth with the handle is 25 3 16 Note Technical data...

Страница 19: ...bor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 12 month period Products that have been modified to perform outside of specificati...