11
Error
Code
Error
description
Unit Action
Possible
Cause
Solution
E36
Water heater
will not work
Unit will work
normally
The temp sensor
failed.
If the temp sensor is failed, the heater
will not work next time.
The heater
failed.
Check the heater.
The harness or the
PCBs failed
Check the wire connection and the
PCBs.
E37
Drum drying
outlet temp
failed
Drying
function will
not work
Temperature
sensor
Check the inner wire before replacing
the temperature.
E38
Drum drying
inlet temp
failed
Drying
function will
not work
Temperature
sensor
Check the inner wire before replacing
the temperature.
E3A
Drying heater
open circuit
Drying
function will
not work
Drying heater
Push the red part of the temperature
sensor before checking.
Check the inner wire on PCB, Fan
motor heater, temperature sensor.
Check the heater resistance
Lint on fan
wheel and
condenser
Check and clean the lint on fan wheel.
Check the lint in the air condenser.
E40
EEPROM
failed
Unit
stops
operation
memory chip
broken
Memory chip of the PCB broken -
replace the PCB
E70
Button
blocked
Unit can’t
work
Button is
stuck
Re-assemble the control panel.
Содержание CWD1550BL
Страница 14: ...13 WIRING DIAGRAM AND TERMINALS...