JRP Edge Digital Gauge: EGT & Boost + EGT
Page 5 of 5
Manual - EGT + Boost & EGT
Detailed Button Operation Continued...
Short Press
Long Press
Short Press
BAR HIGH
PRESSURE
WARNING
& BAR
BAR Value
-0.99 to 7.0BAR
Wait 5 sec to save
Short Press
Long Press
Short Press
PSI HIGH PRESSURE
WARNING
& PSI
PSI Value
-15.0 to 99.9PSI
Wait 5 sec to save
Long Press
Short Press
EGT HIGH TEMP
WARNING
PSI Value
300 to 999c
Wait 5 sec to save
Short Press
Long Press
Short Press
VOLTAGE OFFSET
CALIBRATION
/V
"Symbols blinking"
Voltage
Wait 5 sec to save
Short Press
Long Press
Short Press
BAR OFFSET
CALIBRATION
/BAR
"Symbols blinking"
BAR Value
-0.66 to 0.34BAR
(PSI Equivalent)
-9.57 to 4.93PSI
Wait 5 sec to save
Short Press
Long Press
Short Press
PSI OFFSET
CALIBRATION
/PSI
"Symbols blinking"
PSI Value
-10.0 to 4.0PSI
(BAR Equivalent)
-0.69 to 0.28BAR
Wait 5 sec to save
Short Press
Long Press
Short Press
COLOUR TWO
(CPW)
Temperature
Range
Wait 5 sec to save
Short Press
Long Press
Short Press
COLOUR THREE
(CPW)
Temperature
Range
Wait 5 sec to save
Short Press
Long Press
Short Press
COLOUR FOUR
(CPW)
Temperature
Range
Wait 5 sec to save
Short Press
Long Press
Short Press
TEMPERATURE
CONTROL
Temperature
Range
Wait 5 sec to save
Fine tune adjustment for PSI pressure offset,
aim for 0.0 PSI when engine not running.
This is where you set the first colour of the
temperature-controlled colour pre-warn
(CPW)
This is where you can set the colour pre warn
function, settings are: Off, 20, 30, & 40 for EGT.
This is where you set the first colour of the
temperature-controlled colour pre-warn
(CPW)
This is where you set the first colour of the
temperature-controlled colour pre-warn
(CPW)
There are 3 different indicator display types.
It's best to view these options when the
vehicle is up to operating temperature.
SCALE INDICATOR
Customise the BAR pressure value to trigger
alarm. Short press for fine tune adjustment,
long press for rapid number adjustments.
Customise the PSI pressure value to trigger
alarm. Short press for fine tune adjustment,
long press for rapid number adjustments.
Customise the Exhaust gas temperature
value to trigger alarm. Short press for fine
tune adjustment, long press for rapid number
adjustments.
This is a left over setting from the factory.
Voltage calibration is disabled. (Even though
it
’
s still showing). Adjustments can be made
in this menu however, the changes will not
save to memory after gauge had been
powered down. Specialised equipment is
required to commit changes to memory.
OFF
►
20
►
30
►
40
►
13.2 to 14.2v
Fine tune adjustment for PSI pressure offset,
aim for 0.0 BAR when engine not running.
/EGT
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS
SHORT PRESS
(YELLOW DEFAULT)
(ORANGE DEFAULT)
(RED DEFAULT)
SHORT PRESS
SHORT PRESS
SHORT PRESS
LONG PRESS