background image

–  1  –

Quick Start Guide

Attach the Brackets

1.

Attach each of the front- and rear-post brackets to the vOLT 
using four of the included bracket screws.

2.

Use an additional two screws to secure each of the rear-post 
brackets at the mid-point on the sides of the vOLT.

3.

Use the screws and cage nuts supplied with the rack to secure 
the vOLT in the rack. (You can adjust the rear-post bracket ears 
to fit different rack depths from 56 cm to 75 cm.)

Lock the Rear-Post Bracket Ears

1.

Lock the position of the rear-post bracket ears using the included 
position-locking screws. 

Ground the vOLT

1.

Ensure the rack is properly grounded and in compliance with 
ETSI ETS 300 253. Verify that there is a good electrical 
connection to the grounding point on the rack (no paint or 
isolating surface treatment).

2.

Attach the grounding wire (#14 AWG) to the grounding point 
on the vOLT rear panel. Then connect the other end of the wire 
to rack ground.

Caution: 

The vOLT includes plug-in power supply (PSU) 

and fan tray modules that are installed into its chassis. All 
installed modules must have a matching airflow direction. 
That is, if the installed power modules have a front-to-back 
(F2B) airflow direction, all the installed fan tray modules 
must also have a F2B airflow direction.

Note:

 The vOLT has the Open Network Install Environment 

(ONIE) software installer pre-loaded on the unit, but no 
vOLT software image. Information about compatible 
software can be found at 

www.edge-core.com

.

Note:

 The drawings in this document are for illustration 

only and may not match your particular model.

1

1

1

2

3

3

Caution:

 Installing the vOLT in a rack requires two people. 

One person should position the vOLT in the rack, while the 
other person secures it using the rack screws.

装置の吸排気に必要な領域を マニ ュ アル上に規定 し て
い る 。

Caution:

 The earth connection must not be removed unless 

all supply connections have been disconnected.

2

1

3

1

2

E092017-CS-R01

15020000xxxxA

www.edge-core.com

16-Port XGS-PON vOLT

ASXvOLT16

1.

16-port XGS-PON vOLT, ASXvOLT16

2.

Rack Mounting Kit—2 front-post brackets, 2 rear-post 
brackets, 20 screws, and 2 ear-locking screws

3.

Power Cord (included with AC PSUs only)

4.

Ground Wire (included with DC PSUs only)

5.

Console Cable—RJ-45 to DB-9

6.

DC Power Cable (included with 48 VDC PSU only)

7.

Documentation—

Quick Start Guide

 (this document) and 

Safety and Regulatory Information

1

Package Contents

2

3

4

5

7

6

Отзывы: