Edge-Core ES4704BD Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.edge-core.com

 

ES4700 series 

Chassis Core Routing 

Switch

 

Содержание ES4704BD

Страница 1: ...i www edge core com ES4700 series Chassis Core Routing Switch...

Страница 2: ...4 and 10 slots with support for various types of line cards and can seamlessly support a variety of network interfaces from 100Mb 1000Mb to 10Gb Ethernet We are providing this manual for your better u...

Страница 3: ...better for 100 Mbps connections Category 5 5e or 6 for 1000 Mbps connections For fiber optic connections you may use 50 125 or 62 5 125 micron multimode fiber or 9 125 micron single mode fiber Industr...

Страница 4: ...iv Caution Do not plug a phone jack connector in the RJ 45 port This may damage this device Les raccordeurs ne sont pas utilis s pour le syst me t l phonique Safety Compliance...

Страница 5: ...Imp dance la terre Power Cord Set U S A and Canada The cord set must be UL approved and CSA certified The minimum specifications for the flexible cord are No 18 AWG not longer than 2 meters or 16 AWG...

Страница 6: ...e en mesure d acheminer un courant nominal d au moins 10 A La prise femelle de branchement doit tre du type mise la terre mise la masse et respecter la configuration NEMA 5 15P 15 A 125 V ou NEMA 6 15...

Страница 7: ...he field ground lead on the tri pole power plug to a valid earth ground line to prevent electrical hazards Warning This switch uses lasers to transmit signals over fiber optic cable The lasers are com...

Страница 8: ...viii...

Страница 9: ...ES4704BD System Features 44 1 5 2 ES4710BD System Features 45 Chapter 2 Hardware Installation 47 2 1 Basic Requirements 48 2 1 1 Site Requirements 48 2 1 2 Temperature and Humidity Requirements 49 2...

Страница 10: ...3 5 SFP transceiver installation 65 2 3 6 XENPAK transceiver installation 66 2 3 7 Copper Cable Fiber Cable Connection 66 2 3 8 Power supply connection 67 Chapter 3 Caract ristiques du syst me ES4700B...

Страница 11: ...1 Product Overview RECOMMENDATION Please read this manual first before using the switch following the instructions to avoid damaging the device 1 1 Product Brief Fig 1 1 ES4704BD Switch Fig 1 2 ES4710...

Страница 12: ...re With a powerful ASIC chip dedicated to high speed route lookup and traffic forwarding through longest match and packet by packet mode the switch ensures enhanced forwarding performance and scalabil...

Страница 13: ...ribute Registration Protocol therefore a more flexible VLAN application results by reducing VLAN configurations due to less VLAN configuration changes Layer 3 Forwarding Layer 3 forwarding is the forw...

Страница 14: ...D can effectively prevent broadcast storms from wasting bandwidth with packet level Broadcast Storm Control function resulting in improved overall system performance Port Mirroring ES4700BD supports P...

Страница 15: ...to other switches using a non crossover twisted pair cable Full duplex IEEE802 3x flow control half duplex backpressure flow control Console management port provided Port working status and statistic...

Страница 16: ...50 60Hz Built in Universal Power Supply Power Consumption ES4704BD 400W Max ES4710BD 1200W Max Operating Temperature 0 C 40 C Storage Temperature 40 C 70 C Relative humidity 10 90 with no condensate D...

Страница 17: ...left side of the board rack allowing one fan tray 4 axial fans for each fan tray Dust gauze is provided on the right of the board rack for filtering air circulation through the rack The power block up...

Страница 18: ...n the power modules 1 4 1 1 1 Board Rack The board rack consists of board slots and a system board The boards are inserted vertically into the ES4704BD 4 unit boards are provided There are four slots...

Страница 19: ...ch panel In addition dust gauze is provided on the right of the board rack for filtering the air circulating through the rack The dust gauze can be unplugged and removed through the back for maintenan...

Страница 20: ...4 1 2 1 Board Rack The board rack consists of board slots and a system board The boards are inserted vertically into the ES4710BD 10 unit boards are provided These include 2 management slots in the m...

Страница 21: ...er specified environmental conditions Three fan trays are attached to the fan tray slots above the board rack and ventilation is provided via 6 axial fans that pump out air Fan trays are hot swappable...

Страница 22: ...ports EM4700BD 12GT12GC supporting 12 Gigabit Combo ports and 12 copper GT ports for layer 2 and layer 3 switching and routing and ipv6 wire speed forward z Dual 10G XFP ports 12 Gigabit Combo ports...

Страница 23: ...ription LED Panel Symbol Status Description On Green Card powered Power Indicator PWR Off Card powered off On Green blink at 1 Hz Cards operating normally On Green blink at 8 Hz System is loading On Y...

Страница 24: ...onsole serial port Users can connect to hosts via this port to perform system debugging configuration maintenance management and host software loading Table 1 2 EM4704BD M12GX SFP Console description...

Страница 25: ...s with 4 Gigabit combo ports RJ45or SFP are also provided 1 4 2 2 1 Front Panel The EM4704BD M24TX4GC provides 24 10 100Base TX ports and 4 Gigabit COMBO slots At the same time it comes with 1 Console...

Страница 26: ...iving data 10 100Base RJ45 port indicator On Green Network connection is normal Status indicator Link Off No network connection present on 10 100Base RJ45 port Transmission Indicator Act Blinking Gree...

Страница 27: ...C 1 4 2 2 5 Front Panel Management Port The EM4704BD M24TX4GC provides a RJ 45 receptacle Ethernet port Users can connect through this management port to hosts for program loading or to connect to rem...

Страница 28: ...tus Description On Green Card powered Power Indicator PWR Off Card powered off On Green blink at 1 Hz Cards operating normally On Green blink at 8 Hz System is loading On Yellow blink at 8 Hz System i...

Страница 29: ...ion Connector RJ 45 receptacle Connector type RS 232 Baud rate 9600bps default Supporting service z Connects to character terminals z Connects to PC serial port and running terminal emulator on PC 1 4...

Страница 30: ...cribes the EM4700BD 12GT RJ45 s front panel indicators Table 1 10 EM4700BD 12GT RJ45 indicator descriptions LED Panel Symbol Status Description On green Card powered Power Indicator PWR Off Card power...

Страница 31: ...es a RESET button for resetting the board 1 4 2 5 EM4700BD 12GX SFP 12 fiber GB ports line card EM4700BD 12GX SFP supports 12 SFP GB fiber ports for layer 2 and layer 3 switching and routing 1 4 2 5 1...

Страница 32: ...vides 12 SFP Mini GBIC Gigabyte fiber transceiver slots The following SFP transceivers are supported by the EM4700BD 12GX SFP z ET4201 SX Gigabit SFP MM 850 nm 500m SX z ET4201 LX Gigabit SFP SM 1310...

Страница 33: ...n On Red blinks at 8 Hz Malfunction status Operation indicator RUN Off Card is powered off and can be removed XENPAK port indicator On Green Network connection on XENPAK transceiver is normal Status i...

Страница 34: ...onic ports twenty four GB optical SFP ports where the eight 1G electronic ports and the first eight 1G optical ports are combo ports Fig 1 12 EM4700BD 8GC16GX front panel view EM4700BD 8GC16GX2XG prov...

Страница 35: ...network connection is normal Status Indicator Left Light Off There is not network connection at SFP transceiver Transmissio n Indicator Right Light Flashes Green Sending or receiving data XFP Interfa...

Страница 36: ...0BD 24TX4GC is the line card model of ES4700BD series switchs It implements the layer2 and layer3 wire speed forward and routing function of twenty four 10 100M electronic ports and four 1G COMBO 4 10...

Страница 37: ...Off There is not network connection at SFP transceiver Transmissio n Indicator Act Flashes Green Sending or receiving data 100MB electronic port indicator On Green 100MB electronic port transceiver ne...

Страница 38: ...d exchange and routing function of 12 port 1G optical electronic combo and 12 port 1G electronic interface and IPv6 wire speed transmission function Double 10G and 12 port optical electronic combo and...

Страница 39: ...On Red 8Hz flash Running status is in failure Running Indicator RUN Off Network Interface Card is off and can be pulled out RJ 45 Interface indicator On Green RJ 45 Interface Network Connection is nor...

Страница 40: ...opper cable RJ45 EM4700BD 12GT12GC2XG supports XFP transceivers of the following types z ET5302 LR XFP 10G Transceiver 10KM z ET5302 ER XFP 10G Transceiver 40km z ET5302 SR XFP 10G Transceiver 300M 1...

Страница 41: ...48 port 1000Mbps optical line card EM4700BD 48GX SFP implements 2 layer and 3 layer wire speed switching and routing function of 48 1000Mbps optical interfaces and IPv6 wire speed transmission 1 4 2...

Страница 42: ...wing kinds of SFP transceiver z ET4201 SX Gigabit SFP MM 850 nm 500m SX z ET4201 LX Gigabit SFP SM 1310 nm 10Km LX z ET4201 LHX Gigabit SFP SM 1310 nm 40Km LHX z ET4201 ZX Gigabit SFP SM 1550 nm 80Km...

Страница 43: ...Indicator Lamp Link Off There is no network connection on XFP Transceiver Transmissio n Indicator Lamp Act On green Receiving or sending data 1 4 2 12 3 Front Panel Interfaces Description EM4700BD 4XG...

Страница 44: ...ches of corresponding power supply modules and screwing off the fixing screws for changing the modules 1 4 3 1 1 EM4704BD AC Alternating Current Power Module When powered by AC inputs the AC power mod...

Страница 45: ...wo power modules will supply power for the whole switch and the corresponding POWER Fail warning indicator for the failed missing module will illuminate prompting the replacement of the failed module...

Страница 46: ...e same time it provides power supply to the two power supply modules After the D C output is disposed on the backplane it provides power supply to the modules and fan tray The lower part of the power...

Страница 47: ...modules are equalized and coupled A wiring clip is provided above each 220V 110 VAC input socket for the positioning of power cords and easier wiring In addition on the left side of the AC distributi...

Страница 48: ...ensuring sufficient ventilation for the devices hence enhancing the stability of devices even under high temperature environments Each fan assembly consists of 2 axial fans which are protected by the...

Страница 49: ...environments Each fan assembly consists of 2 axial fans which are protected by the fan tray to prevent bodily injury Please note that the fan blades still spin at a high speed when disconnected from...

Страница 50: ...ES4710BD Dust Gauze The ES4710BD s dust gauze lies under the board rack and prevents large particles in the air from entering the switch The dust gauze should be inserted from the front of the ES4710...

Страница 51: ...panel Never lift or move the switch with these handles The rear panel is shown below FIG 1 30 ES4704BD Rear Panel View 1 4 8 2 ES4710BD Rear Panel The rear panel of the ES4710BD covers the switch back...

Страница 52: ...42 FIG 1 31 ES4710BD Rear Panel View 1 4 9 Side Panels...

Страница 53: ...ew Please do not block the ventilation openings and ensure that enough clearance is left on both sides of the switch for air circulation Failure to do so can cause the chassis to overheat and the syst...

Страница 54: ...hat enough clearance is left on both sides of the switch for air circulation Failure to do so can cause the chassis to overheat and the system to fail or damage to components 1 5 System Features 1 5 1...

Страница 55: ...pplies Nominal Input Voltage AC 90 264 VAC 50 60Hz supporting 1 1 redundant backup of power modules Power Consumption 400 W Forwarding Mode Store and forward Table 1 24 ES4704BD System Features 2 Prop...

Страница 56: ...t Voltage AC 90 264 VAC 50 60Hz supporting 2 1 redundant backup of power modules Power Consumption 1200 W Forwarding Mode Store and forward The ES4710BD Switch system features are described in the tab...

Страница 57: ...oggles 9 Do not perform any operation that may result in bodily injury or damage to the device 10 When cleaning the switch do not use a damp cloth to wipe the switch and never wash the switch with liq...

Страница 58: ...doors and have the following requirements Ambient temperature 0 40 C Humidity 10 90 non condensing The ES4700BD is equipped with a fan assembly for providing the switch with an appropriate level of co...

Страница 59: ...w Temperature Relative humidity Long term condition Short term condition Long term condition Short term condition 15 30 C 0 40 C 40 65 10 90 A sample of ambient temperature and humidity should be take...

Страница 60: ...ing ESD damage 1 Ensure proper earth grounding of the device 2 Perform regular cleaning to reduce dust 3 Maintain proper temperature and humidity 4 Always wear an ESD wrist strap and antistatic unifor...

Страница 61: ...of the switch after installation to avoid the aforementioned If a standard 19 rack is not available the ES4700BD can be placed on a clean level desktop leave a clearance of 100mm around the switch for...

Страница 62: ...ny item is missing or an incorrect item has been supplied please contact your dealer as soon as possible 2 2 1 Checking Switch Hardware Configuration and Accessories After verifying site requirements...

Страница 63: ...h as the checklist 2 2 2 Required Tools and Utilities z cross screwdrivers z Flat blade screwdriver Required tools z ESD preventive wrist strap z Serial port cable z Multi mode fiber cable z Single mo...

Страница 64: ...g point Place the ES4704BD safely on the workbench avoid obstructions on any side of the switch To avoid damage do not place any weight on the switch 2 3 1 2 Rack mounting ES4700BD z Note Before mount...

Страница 65: ...herwise the switch will not be able to mount into a standard rack Note that the hangers are not weight bearing They are used to fasten the switch The mounting Shelf or sliding rails bolt to the rack w...

Страница 66: ...d carry it to the rack Lift the ES4700BD to a position a little higher than the mounting shelf or sliding rails resting the chassis on the shelf rails and then carefully slide the chassis into the rac...

Страница 67: ...the equipment end of the strap into the antistatic socket indicated by an ESD symbol in the switch front panel 2 3 2 Switch grounding A good grounding system is the groundwork for the smooth and safe...

Страница 68: ...ling procedures are listed below Step 1 remove the nuts from the rear chassis grounding posts Step 2 wrap one end of the green and yellow grounding cable to the grounding posts Step 3 attach the groun...

Страница 69: ...l fasteners in the front plate 2 3 3 2 Removing and installing the Dust Gauze Dust gauze is provided in the right section of the ES4700BD which can be installed and removed from the back of the switch...

Страница 70: ...ively simple To install just hold the fan tray in the correct direction align with the corresponding slot and push to secure Tighten the panel fasteners in the font panel Upon removal first loosen the...

Страница 71: ...y simple To install just hold the fan tray in the correct direction align with the corresponding slot and push to secure The locker in the front panel of the fan tray will lock automatically Upon remo...

Страница 72: ...odule to be replaced Step 2 Loosen the 2 panel fasteners in the front panel of the power supply module to be replaced by turning the screwdriver counter clockwise Step 3 Hold the handle in the upper f...

Страница 73: ...he system The procedures are provided below Step 1 Loosen the 2 panel fasteners in the front panel of the power supply module to be replaced by turning the screwdriver counter clockwise Step 2 hold th...

Страница 74: ...e Please perform cleaning on a regular basis according to the site conditions z Pulling the lower dust gauze front panel draw the dust gauze and front panel out z Clean the dust gauze with a brush nev...

Страница 75: ...ng to a back end PC Step 1 Find a PC with Ethernet Interface Step 2 Connect the PC to the RJ 45 Ethernet port of the switch with a twisted pair crossover cable z Remote Administration of the device St...

Страница 76: ...the 10GB line card Step 4 Tighten clockwise the panel fasteners in the front of XENPAK transceiver until fastened to the front panel of the 10GB line card Note the XENPAK 10GB fiber transceiver is hot...

Страница 77: ...must not exceed the maximum received power of the corresponding modules otherwise it will damage the switch Do not stare at the fiber bore when the switch is in operation to avoid harm 2 3 8 Power sup...

Страница 78: ...8 If the Power OK indicator does not illuminate after repeating the above steps please contact the dealer Do not open the switch chassis by yourself Please contact the dealer in the case of any failur...

Страница 79: ...sions physiques 440mm x 266mm x 421mm L x H x P Humidit relative 10 90 sans condensation Temp ratures de fonctionnement 0 C 40 C Alimentations Tension nominale d entr e AC 90 264 VAC 50 60Hz prise en...

Страница 80: ...r e AC 90 264 VAC 50 60 Hz prise en charge 2 1 secours redondant de modules d alimentation Consommation lectrique 1200 W Mode de transfert Store and forward Stocke et transf re Les caract ristiques du...

Страница 81: ...vec du liquide Avertissement de s curit 1 Des avertissements de s curit apparaissent au fil de cette publication se r f rant des op rations qui peuvent vous blesser si elles sont mal r alis es 2 Lisez...

Страница 82: ...avec assez d espace L air conditionn est recommand dans des zones expos es de fortes temp ratures l t z Pour refroidir les circuits internes le switch est livr avec des ensembles de ventilateurs inte...

Страница 83: ...fonctionnement exceptionnelles renvoient des valeurs de temp rature ambiante et d humidit relative qui peuvent survenir pendant une panne du syst me d air conditionn et les conditions de fonctionnemen...

Страница 84: ...gnes de signaux et lignes de sortie Il faut noter les points suivants 1 Il faut prendre des pr cautions pour viter les interruptions de la source d alimentation 2 Le syst me doit avoir sa propre mise...

Страница 85: ...en entr e est indiqu e ci dessous Tension nominale d entr e AC 90 264 VAC 50 60Hz Consommation lectrique totale 1200W Avant d installer les modules d alimentation veuillez v rifier l entr e lectrique...

Страница 86: ...s rie 1 4 Cordon de mise la masse 1 5 Porte ch ssis 2 6 Vis support 8 7 Vis rack 8 8 CD Manuel 1 9 Certificat de qualification 1 10 Carte de garantie 1 Une configuration de base de l ES4710BD doit com...

Страница 87: ...fa on stable tous les modules l int rieur du ch ssis sont compl tement install s aucune obstruction n est pr sente l int rieur ou autour du rack le switch est situ pr s du rack pour faciliter l insta...

Страница 88: ...ntement le ch ssis ensemble et amenez le sur le rack Soulevez l ES4700BD jusqu une position un peu plus haute que l tag re de montage ou les rails de montage en reposant le ch ssis sur l tag re rails...

Страница 89: ...ue pendant l installation du switch Pour viter tout d g t sur le dispositif vitez tout contact entre les circuits imprim s et vos v tements vitez tout contact du corps avec les composants des circuits...

Страница 90: ...masse jaune et vert La mise la masse pour prot ger contre la foudre est une exigence du b timent pas une exigence sp cifique au switch z Mise la masse pour conformit lectromagn tique Ceci renvoie la m...

Страница 91: ...necteur ESD du panneau avant du switch tape 4 Desserrez la plaque arri re de verrouillage des fixations du panneau dans le sens inverse des aiguilles d une montre et enlevez la plaque arri re tape 5 I...

Страница 92: ...tre enlev es et install es facilement Elles peuvent viter que de gros d bris ou des particules dans l air ne soient ing r es par le module d alimentation lectrique Veuillez effectuer un nettoyage de...

Страница 93: ...RS 232 Les proc dures de connexion sont list es ci dessous tape 1 Trouvez un terminal texte ou un PC avec un port s rie RS 232 tape 2 Branchez le port s rie RS 232 du terminal texte sur le port de co...