| Installing the Switch
Mounting
– 36 –
M
OUNTING
This switch can be mounted in a standard 19-inch equipment rack or on a
desktop or shelf. Mounting instructions for each type of site follow.
R
ACK
M
OUNTING
Before rack mounting the switch, pay particular attention to the following
factors:
◆
Temperature: Since the temperature within a rack assembly may be higher
than the ambient room temperature, check that the rack-environment
temperature is within the specified operating temperature range.
◆
Mechanical Loading: Do not place any equipment on top of a rack-mounted
unit.
◆
Circuit Overloading: Be sure that the supply circuit to the rack assembly is
not overloaded.
◆
Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than direct
connections to the mains.
To rack-mount devices:
1.
Attach the brackets to the device using the eight M4 screws provided in the
Rack-Mounting Kit.