– 2 –
Mount the Device
1.
Separate the rack-rail assembly into two sections.
2.
Use the included ten screws to attach the bracket to each side of the
device.
3.
Slide the device into the rack.
4.
Hold it in place and secure the rack-assembly to the front post using
four screws.
5.
While holding the device in place, slide the inner section of rack-rail
assembly from the back until it fits the rear post.
6.
Secure the rack-rail assembly to the rear using four screws.
Ground the Device
Connect Power
DC Power
Install two DC PSUs and then connect them to a DC power source.
Warning:
For a safe and reliable installation, use only
the accessories and screws provided with the device. Use
of other accessories and screws could result in damage to
the unit. Any damages incurred by using unapproved
accessories are not covered by the warranty.
Avertissement:
Pour une installation sûre et fiable,
utilisez uniquement les accessoires et les vis fournies avec
l’appareil. L’utilisation d’autres accessoires et vis pourrait
endommager l’appareil. Les dommages causés par
l’utilisation d’accessoires non approuvés ne sont pas
couverts par la garantie.
Caution:
The device must be installed in a restricted-access
location.
Attention:
L’appareil doit être installé dans un emplacement
à accès restreint.
Note:
The drawings in this document are for illustration only
and may not match your particular model.
1
Caution:
The chassis ground connection must not be
removed unless all supply connections have been
disconnected.
Attention:
Le raccordement à la terre ne doit pas être retiré
sauf si toutes les connexions d’alimentation ont été
débranchées.
Caution:
The device must be installed in a restricted-access
location. It should have a separate protective ground terminal
on the chassis that must be permanently connected to a well
grounded chassis or frame to adequately ground the device
chassis and protect the operator from electrical hazards.
Attention:
L'appareil doit être installé dans un emplacement
à accès restreint. Il doit comporter une borne de terre de
protection distincte sur le châssis, qui doit être connectée en
permanence à la terre pour assurer une mise à la terre
adéquate du châssis et protéger l'opérateur des risques
électriques.
2
Verify Rack Ground
Ensure the rack on which the device is to be mounted is properly
grounded and in compliance with ETSI ETS 300 253. Verify that there is
a good electrical connection to the grounding point on the rack (no
paint or isolating surface treatment).
Attach Grounding Wire
Attach a lug (not provided) to a #8 AWG minimum grounding wire (not
provided), and connect it to the grounding point on the device rear
panel. Then connect the other end of the wire to rack ground.
3