6
Part 1
Installation
ELECTRIC FAN ASSISTED OVEN
General instructions
Connection to the mains
The appliance referred to in this manual has been
manufactured in conformity to the following directives:
73/23/EEC, 93/68/EEC
“Low Voltage”;
89/336/
EEC, 92/31/EEC, 93/68/EEC
“Electromagnetic
Compatibility".
The appliance shall be installed by a qualified
technician according to the regulations and directives in
force in the country where it is installed, as well as the
instructions in this manual. The appliance shall be used
exclusively by trained personnel and only for the purpose
for which it has been designed. The appliance should
be checked once a year by a qualified technician.
Remove the packaging from the appliance as well
as the protective plastic sheet, and, if necessary,
remove traces of glue with a suitable solvent. To
dispose of the packaging, follow local directives.
The technical specifications of the appliance can be
found on the data plate attached to the back panel.
When installing the appliance, all the regulations
in force shall be observed, such as:
Before connecting the appliance to the mains,
compare the electrical set-up data on the data plate
to the characteristics of the local electrical energy
supply.
Adjust the height of the appliance by regulating
the feet, and make sure that it is perfectly level.
The appliance is equipped with a connecting cable
to which the installer must connect a circuit breaker
which cuts off the flow of electricity in all poles; the
distance between the open contacts must be at least
3 mm. The circuit breaker must be easy to reach.
The cable must not be placed near heat sources.
The area around the cable must not have a temperature
above 50
°
C. If the cable must ever be replaced,
consult the wiring diagram attached. The electric
supply cable must not have specifications inferior to
type H07 RN-F. It must have a cross-sectional area of
at least 3x1.5 mm
2
.
To reach terminal board “
M
”, remove the panel
located at the back of the appliance. Disconnect the
terminal board conductors, loosen the cable clamp,
and replace the cable following the procedure
inversely.
It is absolutely necessary to earth the appliance.
For this purpose, there is a screw marked with the
symbol
near the terminal board to which the
earthing conductor must be connected.
The appliance must also be connected to a
unipotential earthing circuit. This connection can be
made using the screw marked with the symbol
,
located below the appliance near the right rear foot.
• all applicable national laws in force;
• all regional or local regulations, such as building
codes;
• directives and regulations of the local electrical
supplier company;
• accident prevention regulations in force;
• fire prevention regulations;
• applicable I.E.C. regulations.
The appliance should be installed under
a hood for the removal of cooking fumes.
If the appliance is installed near walls, panels or
kitchen furniture, etc., they must be made of fire-proof
material; if they are not, they must be protected with
fire-proof material which insulates from heat.
GB IE
Содержание FG60E
Страница 24: ...24...