Troubleshooting - What to do in case of:
If your showcase develops a fault, please check the following table before making a call to your
distributor or technical service.
Problem
Possibble Cause
You must do
The showase doesnt work
The unit is not switched on
Check the unit is plugged in
correctly and switched on
Plug and lead are damaged
Call a qualified Technician
Power supply
Check power supply
Internal wiring fault
Call a qualified technician
Table of parameters
Showcase’s parameters has been adjusted previously for a correct an optimal performance.
If you need to change any parameter:
1. Press the SET button for 8 seconds then the E1 parameter is displayed
2. Use the arrows to select the value desired
3. Press the SET button to store the new values and to move to next parameter.
If no buttons are pressed after 10 seconds the controller exits the adjusting window.
Message
Parameter
Factory value
Range
E1
Maximum temperature value
2ºC
0ºC a 2ºC
E2
Minimum temperature value
6ºC
2 a 45ºC
E3
Temperature buffer
4ºC
1 a 10ºC
E4
Delay of temperature buffer
3 min
0 - 10 min
E5
Fix parameter
0
-
E6
Fix parameter
00
-
F1
Defrosting time
25 min
1 - 60min
F2
Desfrost periods
6 horas
1 -24 hrs
F3
Defrost temperature
20ºC
0 - 22ºC
F4
Temperature Units selection
ºC
ºC