Eden SOFT NC Скачать руководство пользователя страница 16

Vers. 2015-3

16

INSTALLATION, OPERATION

AND MAINTENANCE MANUAL

water cassette

SOFT / SOFT-ECM

RECCOMENDATION

Read the precautions carefully and carry out the procedures correctly:

- In case of failure or malfunction, always apply to authorised service per-
sonnel. 

Any attempt to remove parts, or to maintain the appliance can expose 

the user to danger of electrical shock. The cassette does not contain parts on 
which maintenance can be carried out by the user.

- In case of relocation, apply to service personnel authorised to carry out 
this operation as well as the new installation.
- Do not insert fingers or objects of any kind into airflow outlets or air in-
take grilles. 

There is a fan inside the appliance, which turns at high speed and 

could cause severe personal injury. Pay particular attention to children.

- Do not allow the cold airflow to blow on you directly for long periods 
of time. 

Direct and prolonged exposure to cold air can be dangerous for your 

health. Pay particular attention to rooms where there are children, elderly or 
sick people.

- In case of air conditioner malfunction (e.g. smell of burning), stop ap-
pliance  operation  immediately,  release  the  dedicated  automatic  switch 
and apply to authorised service personnel. 

Prolonged use of the appliance 

in these conditions can cause fire or electrocution.

- During installation of the appliances, avoid letting children or disabled 
have access to the working area. 

Accidents can occur.

- Install the appliance and the remote control at least two metres away 
from television or radio units and from lamps that could irradiate them 
directly. 

Any interference of radio signals can cause operating problems.

- Do not block or cover the airflow intake and delivery grilles. 

The obstruc

-

tion  of  these  openings  causes  a  reduction  of  the  operating  efficiency  of  the 
water cassette, with consequent possible failure or damage.

- Do not use the water cassette for applications such as the storage of 
foods, plants, precision equipment or works of art. 

The quality of the objects 

that are stored could deteriorate.

- Do not expose animals or plants to the direct airflow from the appliance.

Prolonged direct exposure to the cold airflow from the water cassette can have 
a negative effect on animals and plants.

- Do not direct the airflow of the air conditioner towards fireplaces or other 
heating appliances. 

An airflow directed towards the fire can cause incorrect 

combustion and fire.

- Air the room occasionally while using the appliance. 

An insufficient chan

-

ge of air can cause an insufficiency of oxygen in the room.

-  Do  not  allow  the  air  conditioner  to  come  into  contact  with  water. 

The 

electrical insulation could be damaged with consequent possible risk of elec-

trocution.

- Check installation conditions in order to identify possible damage. 

After prolonged use, apply to specialised service personnel to control the instal-

lation conditions of the air conditioner.

- Do not use flammable gas near the air conditioner.
- Always use the appliance with the air filter installed.

Using the air conditioner without the air filter can cause an excessive accumu

-

lation of dust or deposits inside the unit, with consequent possible malfunctio-

ning.

- Release the “automatic” switch if the unit is not going to be used for long 
periods of time.
- Remove the batteries from the remote control if it is not going to be used 
for a long period of time. 

Remove the batteries in order to prevent possible 

problems caused by loss of electrolyte. In case of accidental contact of the bat

-

tery liquid with the skin, eyes or mouth, wash the affected part immediately with 

plenty of water, and see a doctor.

- Please shut off the unit ONLY using the ON/OFF switch (infrared or wall-
mounted remote control).

FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS GIVEN 
IN THIS MANUAL RELIEVES THE MANUFACTURER OF ALL AND ANY LIA-
BILITY. INCORRECT INSTALLATION COULD CAUSE MALFUNCTIONING 
OR FAILURE OF THE APPLIANCE. 
IT COULD ALSO REPRESENT A HAZARD FOR THE USER.

SECOND PART:
FOR THE USER

Содержание SOFT NC

Страница 1: ...SOFT SOFT ECM 2015 3 Installation operation and maintenance manual...

Страница 2: ...operations if any should neither transit nor stop close to the operation area Electric energy and grounding systems are to be connected by expert and qualified personnel in compliance with standards...

Страница 3: ...ystem 8 Cassettes with a control board that is managed onboard 8 Cassettes with and without a control board that is managed onboard 8 INSTALLATION OF AUXILIARY DRAIN PAN 8 CONDENSATE DRAINAGE 9 ELECTR...

Страница 4: ...Coil numbers n 1 1 1 1 1 Hydraulic fitting ISO 228 female gas 1 2 1 2 3 4 3 4 3 4 Air supply in adjacent room mm 150 150 150 150 150 Air supply in adjacent room BxH mm 300x150 300x150 300x150 300x150...

Страница 5: ...tting ISO 228 female gas standard coil 1 2 1 2 1 2 1 2 1 2 1 2 auxiliary coil 1 2 1 2 1 2 1 2 1 2 1 2 Air supply in adjacent room mm 150 150 150 150 150 150 Air supply in adjacent room BxH mm 300x150...

Страница 6: ...ate collecting system comprising internal plastic tray for collecting condensation coming from the heat exchanger external auxiliary plastic tray for collecting condensation coming from the valves and...

Страница 7: ...e grille in the right position for correct connection of the receiver panel to the unit Establish the position and size of the hole in the ceiling using the cardboard mounting template pic 06 To fix t...

Страница 8: ...Always use suitably sized wrenches to fix or slacken the water pipes It is essential to insulate pipes valves and connections correctly in order toavoid the formation of condensation which could drip...

Страница 9: ...te water from the basin to the discharge pipe before blocking the dropped ceiling If the condensate drainage alarm is activated the zone valve is closed and the fan turned off Pic 19 the drain hose is...

Страница 10: ...s 2015 3 10 INSTALLATION OPERATION AND MAINTENANCE MANUAL water cassette SOFT SOFT ECM WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT NC WATER CASSETTE FORESEEN FOR WALL MOUNTED CONTROL WITH 3 SPEED MOT...

Страница 11: ...015 3 11 INSTALLATION OPERATION AND MAINTENANCE MANUAL water cassette SOFT SOFT ECM WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT ECM NC Pic 23 WATER CASSETTE FORESEEN FOR WALL MOUNTED CONTROL WITH EC...

Страница 12: ...2015 3 12 INSTALLATION OPERATION AND MAINTENANCE MANUAL water cassette SOFT SOFT ECM WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT RC Pic 24 WATER CASSETTE WITH INFRARED REMOTE CONTROL WITH 3 SPEED MO...

Страница 13: ...s 2015 3 13 INSTALLATION OPERATION AND MAINTENANCE MANUAL water cassette SOFT SOFT ECM WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT ECM RC Pic 25 WATER CASSETTE WITH INFRARED REMOTE CONTROL WITH EC MO...

Страница 14: ...ther potentially hazardous and disruptive power and SOFTing cables Do not run communication cables in the same conduit of electrical cables and if you cross an electrical cable cross at a 90 angle Do...

Страница 15: ...Vers 2015 3 15 INSTALLATION OPERATION AND MAINTENANCE MANUAL water cassette SOFT SOFT ECM WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT ECM RC MASTER SLAVE EXAMPLE OF MASTER SLAVE SYSTEM...

Страница 16: ...ette for applications such as the storage of foods plants precision equipment or works of art The quality of the objects that are stored could deteriorate Do not expose animals or plants to the direct...

Страница 17: ...will flash Adjust the hours using the or buttons Press the Select button the minutes will flash Adjust the minutes using the or buttons Stop Time Press the Select button PROGRAM STOP will flash on dis...

Страница 18: ...lecomando col simbolo sia stata modificata in impostazione manuale simbolo per tor nare alla modalit standard definita dal produttore procedere come segue Press the Select button 5 times the icon will...

Страница 19: ...place the filters On a sunny day leave the cassette running in fan mode for a few hours to allow the inside of the unit to dry completely Remove the plug or turn off the automatic circuit breaker WHAT...

Страница 20: ......

Страница 21: ......

Страница 22: ...With the perspective of improvement and against the continuous action of research and development the Manufacturer might modify even without any prior notice the given technical data...

Страница 23: ......

Страница 24: ...A GROUP S p A Via Montegrappa 67 31020 San Zenone degli Ezzelini TV ITALY Tel 39 0423 567774 Fax 39 0423 567985 info eden clima com www eden clima com info aliseogroup com www aliseogroup com...