background image

 

PLANNING OF THE 
INSTALLATION 

As there is no wiring work, a wireless alarm 
system is especially easy to installed. 

Easy to make any modification also, as it will be 
very easy to move a detector in order to put it at a 
more efficient location, if necessary.  

For that reason, you do not need to worry about a 
perfect installation before use. 

Before any installation, it is important to evaluate 
carefully the intrusion risks within your house, and 
particularly the external openings. This will allow 
you to define the best locations and the number of 
infrared or magnetic detectors, the need to install 
a deporting siren, a phone alert transmitter, etc.  

Even if the EDEN HA2000 system allows you to 
manage up to 20 accessories, keep in mind that it 
is not necessary to protect all the rooms in your 
house: it is important to protect the main 
entrances or those that have more risks of an 
intrusion, as well as rooms where passage is 
mandatory (hall, access corridor), and those 
where there are the most valuable objects. 

Each home has its own orientation, and the figure 
below is only for your reference. 

 

 

A magnetic detector with a HA2000M opening 
protects the entrance window and door.  

We have protected the living room, where there 
are a stereo, TV, video recorder, etc, with a 
HA2000P infrared detector as well as the 
bedroom and the garage.  

 

 

 

   

PROBLEM?   

 

 

 

 

 

4

  

Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to 

help you make a perfect installation.

 

Содержание HA2000

Страница 1: ...HA2000 HA2000Y Wirefree Alarm System 20 Zones Installation Operating Manual...

Страница 2: ...present in your house Built in power supply All parts of the system are supplied with two years lifetime batteries the system can be installed in a place where 220V power supply is not available Easy...

Страница 3: ...call us via our assistance hotline at the end of the notice Our technicians will have the pleasure to help you make a perfect installation 3 6V AA Size Lithium battery for Door Contact 3V CR2032 Lithi...

Страница 4: ...en if the EDEN HA2000 system allows you to manage up to 20 accessories keep in mind that it is not necessary to protect all the rooms in your house it is important to protect the main entrances or tho...

Страница 5: ...s these keys to move the cursor and scroll the display upwards or downwards 5 Key In Programming mode or Users menu use this key for deleting a digit canceling the selection aborting the current scree...

Страница 6: ...er tighten z Close the lid and tighten the large lid fixing screw with a coin III Getting Started Step 1 Find a suitable location for the Control Panel to be installed Step 2 Insert the batteries You...

Страница 7: ...T to move the cursor downwards or upwards The screen is also scrolled down or up respectively The following items can be selected 9 Walk Test 9 Gen Settings 9 Devices Step 6 After making a selection...

Страница 8: ...ear the code field Pressing while the code field is empty the screen will return to General Settings screen the original PIN Code is retained Step 4 The screen will return to the previous screen where...

Страница 9: ...screens the value displayed on the screen or the option that the cursor underlined is the current setting of each item If it is not necessary to change the current setting just press to escape 3 Entr...

Страница 10: ...i m e O f f z Press S T keys to select the option z Press OK to confirm z Chime Low is set as factory default N NO OT TE E If Chime Low or Chime High is selected when an Entry Door Contact or PIR is...

Страница 11: ...TE E The categories of devices are listed as followings 9 HA2000M Open Contact DC 9 HA2000P PIR detector PIR 9 HA2000S Smoke detector SD 9 HA2000R Remote Controller RC 9 HA2000K Remote Keypad KP 9 HA...

Страница 12: ...n to indicate a successful transmission z Battery The Remote Controller uses one CR2032 3V 230 mAh Lithium battery as its power source Battery life is over 2 years in a normal domestic environment The...

Страница 13: ...ntroller StepC8 Press OK adding a Remote Controller is now completed screen returns to the Device menu N NO OT TE E Zone number is automatically assigned by the Control Panel Press all the learning se...

Страница 14: ...activated door opened or door closed the LED will light z When the cover is opened and the tamper switch is violated the LED will light z When the tamper condition persists every time the Open Contac...

Страница 15: ...entered the Control Panel will respond with a Burglar Alarm z If the Open Contact has been set to Entry and triggered when the system is in Disarmed mode the Control Panel will sound a ding dong Chim...

Страница 16: ...to Device menu PIR Detector HA2000P With Digitalized Adaptive Signal Processor DASP algorithm enables this PIR to pick up movements within an assigned area and signals the Control Panel to activate t...

Страница 17: ...z Battery z The PIR uses one 3 6 V Lithium battery as its power source The PIR will have a typical battery life of 5 years at an average of 20 activations a day z Low battery detection operates at a...

Страница 18: ...ected Help Watch is confirmed you are requested to choose between Personal Attack or Medical device mode P e r s o n a l A t t a c k M e d i c a l N NO OT TE E P for Personal Attack Help Watch Control...

Страница 19: ...they will work in 2 different device modes Step F5 After the detected device is confirmed you are requested to choose between Internal Alarm or External Alarm mode I n t e r n a l A l a r m E x t e r...

Страница 20: ...sound with Burglar message for dialler and Control Panel HA2000P HA2000M 24 Hour H Detector supervised 24h 24h f Sirens Ext Int and Control panel strong and swept sound with Burglar message for dialle...

Страница 21: ...vice choose Remove Device in the Device menu The display will show S T A R T T Step 1 Use S T keys to scroll the display All the used zones with the device names are listed in order of the zone number...

Страница 22: ...owing message will be displayed in Step 3 P l e a s e a d d o n e d e v i c e The message will be displayed for 2 sec then the screen returns to Device menu You are requested to add a detector or Remo...

Страница 23: ...side to side twice Operation I User Menu 1 Power Saving Waking Up The Control Panel is battery powered to conserve the battery power and to prolong the battery life the Control Panel is put in Power...

Страница 24: ...d by using the Remote controller or the Remote Keypad If the Outdoor Bell Box is included in the system it will beep once and the strobe will flash once after the Exit Delay has expired 2 Stopping the...

Страница 25: ...lay time is up the Control Panel will sound three short beeps The system is in Home Arm Mode and the LCD display stays blank N NO OT TE E You can also put the system into the Home mode by pressing the...

Страница 26: ...Contact or PIR Sensor is triggered the Control Panel will activate the alarm providing the Entry Delay has expired z If the 24 HR Fire alarm Personal Attack Alarm device is triggered the Control Pane...

Страница 27: ...to enter your PIN code Step 2 If the PIN code is correct then the alarm sounding will be stopped and the display will show the source of the alarm A l a r m e d b y P I R Z 0 1 The sensor which trigg...

Страница 28: ...l respond as below z When the system is in Disarmed mode the Control Panel will generate an Internal alarm where the Control Panel will sound its internal siren not activate its External Siren Bell Bo...

Страница 29: ...l be displayed S T A R T T Step 3 The log can now be scrolled up and down and viewed with the S T keys the most recent event will be at the start Step 4 An example of logged event is given below where...

Страница 30: ...rmance z In a corner to give the widest view z Where its field of view will not be obstructed e g by curtains ornaments etc z Mounting Method z The PIR is designed to be mounted on either a flat surfa...

Страница 31: ...o mount the Open Contact by either Self adhesive installation or Screw mounting z Self adhesive mounting Step 1 Clean the surface with a suitable degreaser Step 2 Remove the protective covering from o...

Страница 32: ...JP1 in the normal Off position Screw the Cover assembly back onto its base Step 7 Installation is now completed N NO OT TE E Ensure the TEST NORMAL jumper is in the normal Off position when testing i...

Страница 33: ...tamper protection by putting the Control Panel into Programming Mode N NO OT TE E The Programming Mode will automatically quit after 10 minutes if no keys are pressed z Loosen front screw with a coin...

Страница 34: ...ay requesting you to Enter Code Step 6 Enter key 7 and 9 Step 7 All logs cleared and the display shows Clear Log z If key is pressed then the unit will revert to normal alarm on mode z If more than 17...

Страница 35: ...T LED Orange z Orange LED on Arm Memory z Orange LED flash system failure panel tamper AC fault sensor temper sensor out of order open door N NO OT TE E When idle all LED s are off After any key press...

Страница 36: ...empt to open the lid or to detach HA2000K from its mounting surface z Tamper protection is disabled when in Test Mode z Mounting KP 9 z Remove the 2 slide out sections of front cover z Using the 2 mou...

Страница 37: ...you have forgotten the Pin Code or anything wrong happened in the HA2000K you can reset the HA2000K to factory default and reinitialize it Reset to factory default Step 1 Remove one of the batteries...

Страница 38: ...________ Phone No 3 ______________________________ Phone No 4 ______________________________ Phone No 5 ______________________________ Phone No 6 ______________________________ This information is con...

Страница 39: ...extra wired detectors NC loop Double tamper protection back mount cover LED light Default Test mode Transmitted signals Opening Closing Weak battery Tamper Tamper closed Supervision and Test Mode Bat...

Страница 40: ...W 69mm H Waterproof IP44 Polycarbonate UV resistant Guaranty This product is guarantee 4 years except the batteries The first year is by standard exchange The 3 years left the guarantee is for parts...

Страница 41: ...PROBLEM 7 Do not HESITATE to call us via our assistance hotline at the end of the notice Our technicians will have the pleasure to help you make a perfect installation...

Отзывы: