background image

©

2007 Edelbrock Corporation

Brochure No. 63-641580

Catalog #641580, 541583, 641590, & 641593

Rev. 10/07 - AJ/mc

Page 4 of 4

Edelbrock Corporation, 2700 California St., Torrance, CA 90503

Tech Line: 800-416-8628

E-Mail: [email protected]

Fig. 8

Fig. 9

18. Connect other large (12 gauge) red relay wire to

po) battery terminal.

19. Connect small pink relay wire to 12V switched (key-on)

power supply (e.g. terminal in fuse box or splice on
ignition switch).

20. Connect black relay wire and black fuel pump lead wire

to good chassis, engine, or battery ground.

SET-UP & OPERATION

21. Turn ignition on, but DO NOT START ENGINE. Check

system thoroughly for leaks.

Turn ignition off

immediately if a leak is present and repair leak. Factory
preset fuel system pressure for edelbrock fuel pump
(1791) is 6.5 psi. The fuel system pressure can be
externally adjusted from 5 psi to 10 psi.

refer to

Edelbrock fuel pump 1791 instructions for further
details.

22. Start engine and evaluate system operation. Re-adjust

fuel pressure if needed.

23. After a few driving cycles, re-check for and repair any

leaks present. Check fuel system pressure and adjust
the fuel pump, if necessary.

Отзывы: