The following precautions are to be observed at all times when using the LYNCS

TM

 scanner. Please review them 

before utilising the system. 

 

Keep this document in a safe place for future reference. 

 

Observe all warnings, notes and instructions as marked on the packaging, the scanner and the user 
manual. 

 

For transportation, ensure all correct safety precautions are followed as dictated by the relevant local 
governing bodies. 

 

The  equipment  must  not  be  used  for  purposes  other  than  those  intended.  Eddyfi  assumes  no 
responsibility for any damage resulting from such improper usage. 

 

Do not use substitute parts or perform unauthorized modifications to the system. 

 

If the system does not operate normally, please contact Eddyfi for assistance. 

 

 

Safety Markings and Symbols 

STRONG MAGNETIC FIELD -

 The wheels of the scanner contain magnets that produce an extremely 

strong  magnetic  field  which  may  cause  failure  or  permanent  damage  to  items  such as watches, 
memory devices, CRT monitors, and medical or other electronics devices. 

 

Strong magnetic fields pose a variety of risks, especially to people who wear implanted cardiac devices 
like pacemakers and defibrillators. 

 

RISK OF FINGER TRAP -

 Tools, magnets, and metal objects can cut, pinch, or entrap hands and fingers. 

HANDLE WITH CARE. 

 

 

Copyrights 

This document and the product and programs it describes are protected by copyright laws in the UK, by laws of 
other countries, and by international treaties, therefore may not be reproduced, in whole or in part, whether 
for  sale  or  not,  without  prior  written  consent  from  Eddyfi  UK  Ltd.  Under  copyright  law,  copying  includes 
translation in other languages and formats. 

 

© Eddyfi UK Ltd, 2020 

 

This document was prepared with particular attention to usage to ensure the accuracy of the information it 
contains. It corresponds to the version of the product manufactured prior to the date appearing on the inside 
front cover. There may, however, be some differences between this document and the product, if the product 
was modified after publication. 

 

The information contained in this document is subject to change without notice. 

 

 

Содержание LYNCS-CM

Страница 1: ...e cannot accept either legal responsibility or any liability for any incorrect statements which may remain and their consequences The following documentation is protected by copyright All rights reser...

Страница 2: ...eral 3 Safety Markings and Symbols 3 Copyrights 3 LYNCSTM 4 LYNCSTM Scanner Frame Overview 5 LYNCS WI Overview 9 LYNCS WI Operation 14 LYNCS CM Overview 15 LYNCS CM Operation 17 LYNCS System component...

Страница 3: ...2 General Precautions and Conventions...

Страница 4: ...memory devices CRT monitors and medical or other electronics devices Strong magnetic fields pose a variety of risks especially to people who wear implanted cardiac devices like pacemakers and defibril...

Страница 5: ...4 LYNCSTM...

Страница 6: ...5 LYNCSTM Scanner Frame Overview Top View Side View Rear View...

Страница 7: ...ief Point Used to provide strain relief on the encoder cable Prior to use ensure the encoder strain relief is applied Failure to do so could result in encoder cable or tractor unit damage Do not use s...

Страница 8: ...oints Ensure the unit is tethered centrally to each attachment point at all times to prevent the scanner from falling Prior to use ensure the end caps and each tractor unit are securely fastened on th...

Страница 9: ...176 F Minimum ambient temperature 20 C 4 F Maximum ambient temperature 50 C 122 F Minimum storage temperature 10 C 14 F Maximum storage temperature 40 C 104 F Circumferential scanning 100mm 4 to flat...

Страница 10: ...9 LYNCS WI Overview Top View Tool Post Assembly Side View 6 7 8...

Страница 11: ...ugged directly into the instrument and scanner Do not connect the adapter cable Connecting the adapter cable will enable Increment Encoder Reset functionality Adapter supplied with LYNCS FULL LYNCS CM...

Страница 12: ...edge setup Tilt tool posts forwards when on the inspection surface 6 Removable central handle Accessory which can be mounted to scanner rail to aid stability and maneuverability Do not remove scanner...

Страница 13: ...h of the tool post arms loosen thumbscrew at rear of tool post and move arm to desired position tighten thumbscrew to lock tool post arm in place Threaded holes are used to receive 5mm and 8mm diamete...

Страница 14: ...s 40 mm 1 5 in Maximum number of tool posts 6 Tool posts compatibility Max wedge dimensions L87 W40 H45 5mm female wedge 8mm female wedge 5mm male pin wedge Weight scanner and 2 x tool posts 3 kg 6 6...

Страница 15: ...cable management sleeve to strain relief points 9 Set toolpost in desired position along rail and lock into place If utilising outer toolposts do not set for pipe diameter until on the test item 10 T...

Страница 16: ...r cable Adapter only supplied with LYNCS FULL LYNCS CM To use Pause Resume functionality remove the adapter cable and plug encoder cable directly into instrument and scanner 2 Rail Holes Waterbox moun...

Страница 17: ...lever to unlock the spring loaded pin in the mechanism As the waterbox slides along the rail the pin will automatically drop into the next hole LYNCS CORROSION MAPPING SPECIFICATIONS Dimensions w d h...

Страница 18: ...bration and complete remaining setup configuration 10 Tether scanner from both handles 11 Place onto test item to perform scan 12 Start data acquisition on instrument and move scanner forward 13 Apply...

Страница 19: ...ting Waterbox foam seals 25 LYNCS CM Nanuk transport PELI CASE Cable management sleeve Portable site bag LYNCS Frame 412mm 16 2 Hose guides 4 Waterbox Large rails Metric 667mm 2 Cable guides 4 Waterbo...

Страница 20: ...19 LYNCSTM Maintenance...

Страница 21: ...adapter lead for Pause Resume functionality Connection issue Remove handle and check the white connector is securely connected See images 1 4 below Insufficient probe contact Weld Inspection Tool post...

Страница 22: ...ket cap bolts and encoder housing 2 Carefully lift off handle cover making sure not to place excess strain on wiring 4 Remove Fischer socket nut and disconnect JST connector white part in image to rem...

Отзывы: