background image

17 

 

LYNCS-CM Operation 

 

 

 

 

1.

 

Remove one tractor assembly. 

2.

 

Slide on any cable management guides required. 

3.

 

Arrange tractor units and affix waterbox mount onto rail depending on required application 

4.

 

Insert  waterbox  and  secure  into  waterbox  mount.  The  waterbox  height  will  need  to  be  adjusted 
when on test item. 

5.

 

Insert encoder cable and attach strain relief to strain relief point. 

6.

 

Attach cable management sleeve to strain relief points. 

7.

 

Attach LYNCS-CM Adapter lead to instrument and end of encoder cable.  

8.

 

Setup  data  acquisition  unit

  for  M2M  instruments  select  LYNCS-CM

 

in  scanner  list  NOTE:  Typical 

encoder resolution: 25.85 pts/mm. 

9.

 

Perform encoder calibration and complete remaining setup configuration. 

10.

 

Tether scanner from both handles. 

11.

 

Place onto test item to perform scan. 

12.

 

Start data acquisition on instrument and move scanner forward. 

13.

 

Apply brakes and press button on tractor assembly to increment step on the instrument. Turn lever 
lock to release pin from drilled hole and slide along rail, the pin will automatically drop into the next 
hole. 

14.

 

Release brakes and move scanner backwards. Repeat step 13 to build 2-Axis stitched C-Scan.  

 

If not using an M2M instrument, the following changes in step 13 will need to be applied; 

Step 13 - Apply brakes, increment step on the instrument, turn lever lock to release pin from drilled hole and 

slide along rail, the pin will automatically drop into the next hole 

 
NOTE: A long press on the tractor assembly button will reset the scan direction encoder to zero. 
 

 
 
 
 

 
 

 

 

Содержание LYNCS-CM

Страница 1: ...e cannot accept either legal responsibility or any liability for any incorrect statements which may remain and their consequences The following documentation is protected by copyright All rights reser...

Страница 2: ...eral 3 Safety Markings and Symbols 3 Copyrights 3 LYNCSTM 4 LYNCSTM Scanner Frame Overview 5 LYNCS WI Overview 9 LYNCS WI Operation 14 LYNCS CM Overview 15 LYNCS CM Operation 17 LYNCS System component...

Страница 3: ...2 General Precautions and Conventions...

Страница 4: ...memory devices CRT monitors and medical or other electronics devices Strong magnetic fields pose a variety of risks especially to people who wear implanted cardiac devices like pacemakers and defibril...

Страница 5: ...4 LYNCSTM...

Страница 6: ...5 LYNCSTM Scanner Frame Overview Top View Side View Rear View...

Страница 7: ...ief Point Used to provide strain relief on the encoder cable Prior to use ensure the encoder strain relief is applied Failure to do so could result in encoder cable or tractor unit damage Do not use s...

Страница 8: ...oints Ensure the unit is tethered centrally to each attachment point at all times to prevent the scanner from falling Prior to use ensure the end caps and each tractor unit are securely fastened on th...

Страница 9: ...176 F Minimum ambient temperature 20 C 4 F Maximum ambient temperature 50 C 122 F Minimum storage temperature 10 C 14 F Maximum storage temperature 40 C 104 F Circumferential scanning 100mm 4 to flat...

Страница 10: ...9 LYNCS WI Overview Top View Tool Post Assembly Side View 6 7 8...

Страница 11: ...ugged directly into the instrument and scanner Do not connect the adapter cable Connecting the adapter cable will enable Increment Encoder Reset functionality Adapter supplied with LYNCS FULL LYNCS CM...

Страница 12: ...edge setup Tilt tool posts forwards when on the inspection surface 6 Removable central handle Accessory which can be mounted to scanner rail to aid stability and maneuverability Do not remove scanner...

Страница 13: ...h of the tool post arms loosen thumbscrew at rear of tool post and move arm to desired position tighten thumbscrew to lock tool post arm in place Threaded holes are used to receive 5mm and 8mm diamete...

Страница 14: ...s 40 mm 1 5 in Maximum number of tool posts 6 Tool posts compatibility Max wedge dimensions L87 W40 H45 5mm female wedge 8mm female wedge 5mm male pin wedge Weight scanner and 2 x tool posts 3 kg 6 6...

Страница 15: ...cable management sleeve to strain relief points 9 Set toolpost in desired position along rail and lock into place If utilising outer toolposts do not set for pipe diameter until on the test item 10 T...

Страница 16: ...r cable Adapter only supplied with LYNCS FULL LYNCS CM To use Pause Resume functionality remove the adapter cable and plug encoder cable directly into instrument and scanner 2 Rail Holes Waterbox moun...

Страница 17: ...lever to unlock the spring loaded pin in the mechanism As the waterbox slides along the rail the pin will automatically drop into the next hole LYNCS CORROSION MAPPING SPECIFICATIONS Dimensions w d h...

Страница 18: ...bration and complete remaining setup configuration 10 Tether scanner from both handles 11 Place onto test item to perform scan 12 Start data acquisition on instrument and move scanner forward 13 Apply...

Страница 19: ...ting Waterbox foam seals 25 LYNCS CM Nanuk transport PELI CASE Cable management sleeve Portable site bag LYNCS Frame 412mm 16 2 Hose guides 4 Waterbox Large rails Metric 667mm 2 Cable guides 4 Waterbo...

Страница 20: ...19 LYNCSTM Maintenance...

Страница 21: ...adapter lead for Pause Resume functionality Connection issue Remove handle and check the white connector is securely connected See images 1 4 below Insufficient probe contact Weld Inspection Tool post...

Страница 22: ...ket cap bolts and encoder housing 2 Carefully lift off handle cover making sure not to place excess strain on wiring 4 Remove Fischer socket nut and disconnect JST connector white part in image to rem...

Отзывы: