Versatrax 100™
Document: UMDT013103.docm
Revision: A10
Created by: KJB
Date: 26 Sep 2019
3070984-A10
Source Location: C:\ePDM\ISLEng\products\dt-versatrax100mkii\manuals\UMDT013103.docm
Page 38 of 41
Us
er
M
an
u
al
Fuse Replacement
The Versatrax
™ interface box is fitted with fuses for its AC power inlet and DC tether power output supply
rails. These fuses are accessible from the rear of the interface box. Replace fuses with the same type and
rating only.
Caution:
A blown fuse is an indication of possible component failure. If, after restoring power, the system
does not operate normally or if the circuit blows a second time, please contact Eddyfi Technologies
technical support.
AC Line Input
Fuses
Power cord
inlet (drawer)
AC input fuses (2)
6.3A 250V, Time Delay, 5x20mm (Bussmann S506-6.3-
R)
Tether Output
Fuse, (70VDC)
Rear panel
Output supply to the tether and vehicle.
7A 125VDC, Fast, ¼ x 1-
¼” (Bussmann ABC-7-R)
Tether Output
Fuse (48VDC)
Rear panel
Output supply to the tether and vehicle.
7A 125VDC, Fast, ¼ x 1-
¼” (Bussmann ABC-7-R)
CAUTION: DOUBLE POLE / NEUTRAL FUSING. This power supply contains fuses on both AC input
lines. Disconnect power before servicing.
Microtrac™ Maintenance
Refer to the Microtrac manual for Microtrac maintenance and servicing instructions.
Camera Maintenance
Refer to your camera manual for operation and maintenance instructions.
Tether Re-termination
Contact us if tether re-termination is required. Tether re-termination kits are also available. Detailed
instructions and wiring diagrams will be included with the kit.