Connector Handling 

Connectors are an essential part of system reliability. They should be properly maintained and cared for 
to ensure long life and reliability. It is recommended to follow these steps to help prevent damage and 
increase the life of connectors.  

 

Always put the cap back on the tether bulkhead when the tether is disconnected 

 

Always inspect the end of the connector prior to engaging 

 

Never plug in a dirty or damaged connector 

 

Visually align key-ways or locating pins prior to engaging the connector 

 

Always fully engage or tighten the connector 

 

Secure locking collars finger tight 

 

Install dummy plugs on unused connectors 

 

Disconnect by pulling straight, not on an angle 

 

Do not pull on the cable to disengage the connector 
 

IMPORTANT: 

Never “Hot Plug” any connector, this will result in internal damage to the 

electronics. Power down the system prior to connecting the inspection system tether. 

Note:

  Never use WD-40 or similar solvent-based fluids on connectors or crawlers. These will cause 

the rubber parts of the connector or crawler to soften and swell rendering them inoperable.  

SubConn Connector: Lubrication and Cleaning 

 

Periodically apply Molykote 111 silicone grease or equivalent before mating connectors 

 

For dry mate connections, a layer of grease corresponding to 1/10 the socket depth should 
be applied to the female connector 

 

After greasing, fully mate the male and female connector and remove excess grease from the 
connector joint  

 

General cleaning and removal of sand or mud on a connector should be performed using a 
spray-based contact cleaner like isopropyl alcohol 

Impulse Connector: Lubrication and Cleaning 

 

Lubricate mating surfaces regularly with 3M Silicone spray or equivalent, DO NOT GREASE 

 

Lubricate O-rings with Molykote 111 or equivalent 

 

Use dust caps to protect connectors wherever possible 

 

Clean connectors with soap and fresh water, rinse out with alcohol and allow connector to air 
dry before using. 

 

 

Содержание INUKTUN Spectrum 45

Страница 1: ...Eddyfi Robotics Inc 2569 Kenworth Road Suite C Nanaimo BC V9T 3M4 CANADA 1 250 729 8080 info eddyfitechnologies com www eddyfitechnologies com...

Страница 2: ...Out 6 Safety 7 System Setup 8 Unpacking Components 8 Mounting the Camera 8 Galvanic Corrosion Control 9 Connector Handling 10 SubConn Connector Lubrication and Cleaning 10 Impulse Connector Lubricati...

Страница 3: ...by PV Date 08 Dec 2019 IPN 3041015 A14 Source Location C ePDM ISLEng products aa spectrum45 manuals UMAA007219 docm Page 3 of 16 User Manual Warranty Repairs 15 Factory Returns to Canada 15 Product S...

Страница 4: ...without notice Customers will be notified of any changes to their equipment Information in this manual does not necessarily replace specific regulations codes standards or requirements of others such...

Страница 5: ...pth Rating 150 m 500 ft Speed Pan 0 18 s Tilt 0 35 s Range Pan 360 Continuous Tilt 280 140 125 Dimensions 45 x 163 mm 1 75 x 6 4 in Weight Aluminum 0 7 kg 1 5 lb Stainless Steel 1 2 kg 2 6 lb Imager S...

Страница 6: ...Directive 2006 42 EC and Electromagnetic Compatibility Directive 2004 108 EC and Directive 2014 30 EU Connector Pin Out The Spectrum 45 connects to power and communications through a Subconn MCBH8M co...

Страница 7: ...Under no circumstances should this equipment be used in a potentially explosive atmosphere WARNING Intense Optical Radiation The Spectrum 45 camera lights are extremely bright Never look directly at t...

Страница 8: ...e placed in a cardboard box again for shipping purposes This measure greatly reduces rough handling and subsequent shipping damage Mounting the Camera The Spectrum 45 camera may come installed on an E...

Страница 9: ...ras Aluminum anodes are common in the marine industry and are replacing zinc anodes in many areas For cameras systems that are often pulled in and out of the water aluminum anodes are especially impor...

Страница 10: ...y connector this will result in internal damage to the electronics Power down the system prior to connecting the inspection system tether Note Never use WD 40 or similar solvent based fluids on connec...

Страница 11: ...The system should be visually inspected for mechanical damage 2 If the system has been used in salt water thoroughly rinse the camera and pole with fresh water right away Accelerated corrosion will re...

Страница 12: ...nual Video Problems 1 No video black or blue background Interface box is not turned on Video cables are not hooked up between interface box and computer Camera connector on vehicle is loose turn power...

Страница 13: ...ter will be forced into the camera at these high pressures 3 Avoid scratching the camera port Use glass cleaner and a soft cloth to clean the port CAUTION Do not use a pressure washer to clean the cam...

Страница 14: ...from your local office When ordering parts always make sure to quote the sales order acknowledgement SOA number and or the serial number of the system component in question Eddyfi Robotics Inc Canadia...

Страница 15: ...number with detailed shipping and customs instructions Items shipped without an RMA number will be held at Eddyfi Technologies until the correct paperwork is completed If cross border shipments are no...

Страница 16: ...on to improperly wired AC receptacles 5 Track belts tethers view ports and other components subject to wear through abrasion are warranted to be free from defects in material and workmanship for a per...

Отзывы: