MU300 Rev1.0 Oct20
Page 11 of 54
]
Flow Total
NET
POS
NE
Net
POS
NEG
Flow Total
Chapter IV Operation Panel and Quick Start
4.1
Power on
Warning!
Please check the meter is correctly installed or not before power on, including:
Connecting the power supply as specified.
Please check the electrical connection of the supply power is correct or not.
4.2
Boot screen
The flowmeter is composed of the measuring transducer and the signal converter. And the
delivery product is ready for putting into use. All operating parameters and settings have been
set according to your order requirements.
(1) Boot screen
In normal display, press [ and [ ] keys to switch among NET Total, POS Total and NEG Total.
Go on pressing [ ] to enter 01 menu to display the flow rate, total flow and transient flow. The
following shows how to switch between the flow rate and the total flow.
Prompts!
"*R" indicates that the flowmeter is running normally; “D” indicates that the flowmeter is
carrying out gain setting; “E” indicates that the flowmeter can’t receive any ultrasound signals.
Flow Rate
Flow Rate
G