Function F51 Setting Inputs to Trigger or Report
An Input may be configured as triggering or reporting. A triggering Input triggers alarm notification
calls. A reporting Input will not cause the EDAC 222-02 to make any calls. A reporting Input will
speak its message either when the EDAC 222-02 has already been triggered by another Input and
is making an alarm notification call, or when you call into the unit to check its status (active,
cancelled or idle).
Set Input
one
as follows:
51
0
= Triggering Input. This Input dials.
1
= Reporting Input.
When another Input is dialling this Input
reports. This Input will not cause the
EDAC 222-02 to make any calls.
Default: 0 (Triggering)
By default both Inputs are set to triggering. Both Inputs must be programmed separately to change
them from triggering to reporting, as follows:
Use
F51
for Input
1
, as in the example above.
Use
F61
for Input
2
.