EDAC 222-02 AUTO ALARM DIALLER
- 27 -
Function F09 Trigger/Dial Time
This function determines the period to wait from physical trigger to alarm condition and dial out. It
can be used as a trigger delay timer to allow for exit entry time, or can be used with float switches
to ensure the level has got to and is triggering the float switch correctly.
The
latch
capture, (function
F52
)
occurs either when triggered, or at the end of the trig/dial time.
The value displayed is seconds by default. Minutes may be used (see function
F96
)
09
0
= Immediate dial (default).
1
= 1 sec/min
2
= 2 sec/min
3
= 3 sec/min
4
= 5 sec/min
5
= 10 sec/min
6
= 15 sec/min
7
= 20 sec/min
8
= 30 sec/min
9
= 60 sec/min
#
= 120 sec/min
Default: 0 (Start dialling when triggered)
Function F10 Programming Your Pager Messages
When an alarm notification call is made to a
Numeric-Pager
, the message in this function is sent.
Message
one
is entered as follows:
10
Enter pager message followed by a
#
to save
e.g.
2234#
Default: Empty (Displays as
for Empty)
Each of the four Input pager messages must be programmed separately as follows:
Use
F10
for Input
1
pager message
1
as in the example above.
Use
F20
f
or Input
2
pager message
2
.
To reset a pager message to empty:
Select the message, do not enter a message and save
using the
#
key.