background image

ESD CONDUCTIVE CO.,LTD Expert of Static Control

www.esd-conductive.com

Address :

151#,Houjie Dadao, Houjie Town,Dongguan City,China Post code 523961

E-mail: [email protected]

To reduce the risks of fire and explosion which, if not avoided, could result in serious injury or death:
The unit does not incorporate explosion-proof specifications. Never attempt to use it in a place
where there are flammable or volatile gases. Doing so may ignite the gases and cause an explosion.
To reduce the risks associated with hazardous voltage and fire which, if not avoided, could result in
serious injury or death:
Never attempt to disassemble or modify the unit, or alter or repair circuits, as the unit contains
components that generate high voltage. Do not directly touch the inside of the machine, including the
electrode needles. Doing so may result in severe or fatal injury due to the hazardous high voltage
generated internally, or cause a fire or malfunction of the unit.

SECTION ONE FEATURES:

LED TOUCH SCREEN display technology, the display interface is full and bright, compact and intuitive,

real-time monitoring the ion balance. It has a multi-level function menu that can be manually operated, fast
and convenient.

Large air volume, range from one to ten classes air control technology, using large air volume DC fan,

eliminating static electricity quickly and fast.

Unbalanced alarm prompt technology, alarm threshold voltage can be set manually. When the ion

balance voltage is out of balance and exceeds the set threshold voltage, the unit will automatically alarm.

This machine is equipped with automatic cleaning function. The cleaning interval can be set by software.

The default cleaning brush will automatically clean the ion emitting needle two times every two hours.

Optional warm air function. Temperature is adjustable.

Ion balance correction technology, through the air outlet sensing device, automatically corrects the best

effect when the ion deviates from the equilibrium state. You can compensate 100V by touch screen positive
and negative, so that the corrected ion balance can reach the best static elimination performance.

SECTION TWO PRODUCT SPECIFICATION

Input Voltage: 220V 50Hz/110V 60Hz
Power Consumption: Max. 90W
Current Consumption: Max. 0.18Amp
Operating Temperature: -10

°

C ~ +45

°

C

Emitter Point Cleaning: 360

automatic cleaning (default: 2circles every 2 hours)

Balance Voltage:

5V (ANSI/ESD STM3.1-2006 Maximum fan speed, measurement taken 30 cm from fan)

Decay Time:

2s (25

±

5

˚

C, 50

±

10% RH)

Ozone Level: < 0.05ppm
Net Weight: Approximately 3.7kg
Overall Size: 600L*170D*125H mm
Warranty: One year

www.esd-conductive.com

Содержание E-AID202

Страница 1: ...tive com Address 151 Houjie Dadao Houjie Town Dongguan City China Post code 523961 E mail sales01 esd conductive com INSTRUCTION E AID202 Smart Ionizing System with LCD Touch Screen Auto Clean Real Time Ion Balance monitoring w w w e s d c o n d u c t i v e c o m ...

Страница 2: ...ound terminal is connected to a grounded cable and the terminal knob tightened Failure to do so may result in electrical shock Do not position the equipment such that it is difficult to disconnect the plug When doing electrode needle maintenance be sure to disconnect the AC plug from the outlet Do not connect or disconnect the power plug with wet hands as doing so puts you at risk of electrical sh...

Страница 3: ...arge air volume range from one to ten classes air control technology using large air volume DC fan eliminating static electricity quickly and fast Unbalanced alarm prompt technology alarm threshold voltage can be set manually When the ion balance voltage is out of balance and exceeds the set threshold voltage the unit will automatically alarm This machine is equipped with automatic cleaning functi...

Страница 4: ...nd press Ent to end the setting NOTE the setting ranges from 0 99V 2 Ion Balance Voltage Calibration Strongly recommend professional technician to do this setting First of all hand over the unit and keep distance about 300mm or desired distance but within 900mm to make sure proper static elimination performance from the static charged plate meter Make test and adjust the ion Environmental Temperat...

Страница 5: ...tamination Use air drying and cleansing filter regulator with 5 micron filtration Ensure that all connections pipe work and filter regulators will allow minimum 15 CFM of air flow Clean and purge filter regulators periodically and check for contamination in the air delivery pipe From time to time remove the front nozzle cap by unscrewing anti clockwise disconnect from H V electric supply before re...

Отзывы: